DRÄGER E-CAL

Automatic station for testing and calibration DRÄGER E-CAL.
Automatic station for testing and calibration DRÄGER E-CAL (DRÄGER E CAL)
The instrument reliably verifies and calibrates all portable gas detection instruments Dräger.
Dräger E-Cal has a modular design and includes: the main station and up to 10 different modules, which can be simultaneously tested and calibrated gas detection devices connected to your PC.

More info ...

AID-70

199 999 RUB   |   99 999 UAH   |  available: 1 piece
AID-70 аpparatus image.
Apparatus AID-70 (AID70, AID 70)
Designed to test insulation of power cables rectified voltage and solid dielectric sinusoidal voltage with frequency 50Hz;
Output voltage range:
- Constant voltage (peak voltage) - 0kV-70kV;
- AC voltage (rms) - 0kV-50kV;
Load current:
- DC - 0mA-12mA;
- AC voltage - 0 mA to 20 mA;
Highest output voltage (RMS) - 50 kV;
The highest load current (RMS) - 45 mA.

More info ...

AID-70M

99 999 RUB   |   99 999 UAH
AID-70 аpparatus image.
Apparatus AID-70M (AID70M, AID-70-M, AID 70 M, AID 70M)
Designed to test insulation of power cables rectified voltage and solid dielectric sinusoidal voltage with frequency 50Hz;
Regulation of DC negative polarity (peak value) - 2kV-70kV;
Regulation AC (rms) - 2kV-50kV;
Basic relative error of measurement of voltage:
- Ranging from 10kV to 70kV DC - does not exceed ± 3%;
- In the range of 10 kV to 50 kV AC - does not exceed ± 3%.
 

More info ...

AID-70C

269 999 RUB 242 999 RUB  |   134 999 UAH 121 499 UAH  |
Apparatus AID-70TS.
Apparatus AID-70C (AID70C, AID-70-C, AID 70 C, AID 70C)
Designed to test insulation of power cables rectified voltage and solid dielectric sinusoidal voltage with frequency 50Hz;
Measuring range of high-voltage direct current (peak value) - 10kV-70kV;
Measuring range of high voltage AC sine wave (RMS), 50 Hz - 10 kV, 50 kV;
Measuring Range DC Current test dielectric strength - 0.1 mA-10 mA;
Measuring range AC current test dielectric strength - 0.2 mA-50mA;
Outside the main relative error in the measurement of the DC voltage - ± 3%;
Outside the main relative error in the measurement of the AC sine wave, 50 Hz - ± 3;
Limits of basic reduced error in the measurement of dc current - ± 5;
Limits of basic reduced error for measuring the AC sine wave, 50 Hz - no more than ± 5%.

More info ...

AII-70

99 999 RUB   |   99 999 UAH   |  available: 2 pieces
AII-70 device image.

Apparatus AII-70 (AII70, AII 70)
Designed to test cables, solid and liquid dielectrics or rectified AC voltages;
Rated supply voltage single-phase, 50 Hz - 127V, 220V;
The greatest variable voltage - 50kV;
The greatest rectified voltage - 70kV;
Rectified current from the high voltage - 5mA;
Output minutes power high-voltage transformer - 2kVA.


More info ...

AII-70M

99 999 RUB   |   99 999 UAH   |  available: 2 pieces
AII-70M device image.
Apparatus AII-70M (AII70M, AII 70M)
Designed to test cables, solid and liquid dielectrics or rectified AC voltages;
Rated supply voltage single-phase, 50 Hz - 127V, 220V;
The greatest variable voltage - 50kV;
The greatest rectified voltage - 70kV;
Rectified current from the high voltage - 5mA;
Output minutes power high-voltage transformer - 2kVA.

More info ...

АИМ-90

99 999 RUB   |   49 999 UAH   |  available: 2 pieces
device image.

АИМ-90 аппарат испытания масла предназначен для определения пробивного напряжения трансформаторного масла и других жидких диэлектриков, работающих в качестве изолятора в высоковольтных установках.

Наибольшее пробивное напряжение (действующее значение) - 90 кВ.

Объем измерительной ячейки - 400 см3.


More info ...

AIM-90C

Apparatus AIM-90TS.
Apparatus AIM-90C (AIM90C, AIM-90-C, AIM 90 C, AIM 90C)
Designed to determine the breakdown voltage of transformer oil and other liquid dielectrics, working as an insulator in high voltage devices;
Measuring range of high voltage AC specified accuracy - 10kV-90Sqr;
Outside the main relative error in the measurement of the AC sine wave, 50 Hz - no more than 4%;
Output voltage (RMS) - 2kV-90Sqr;
Response voltage protection - ± 92kV 1kV.

More info ...

ИИРТ-400А

available: 1 piece

ИИРТ-400А установка электромеханическая или экструзионный пластомер предназначен для определения показателя текучести расплава термопластов.

Длина экструзионной камеры - 160 мм.

Длина капилляра - 8±0,025 мм.


More info ...

K513

49 999 RUB   |   49 999 UAH   |  available: 11 pieces
K513 device image.

K513 blocks regulation (K-513, K 513)

Supplied with the unit installation U5052. Provides a controlled single-phase AC and rectified DC voltage and current, measurement of the temporal characteristics of the device under test.

More info ...
Pages: 1 2 3 4 5    View all
ОС4-100КИ-12652ТЭМ-6
УПАВ-РмУП-МСРПК535
У-5035УПС-4У5014
У5023У5056АИМ-90
РК2-01АКИ-12548УВЛ 15/25-О
УВЛ 15/50-МСУВЛ 15/65-МСУВЛ 15/80-МС
УВЛ 15-ОИИРТ-400АУПМС-1
AID-70AID-70CAID-70M
AII-70AII-70MAIM-90C
DRÄGER E-CALЭУ5000K513
K514K515The station for the functional verification
U400 (У400)U401UKSI-1 (УКСИ-1)
UPAV-2UPAV-2MUPI-3 (УПИ-3)
Y300 (У300)У1134МУ358
У5052У5053УППУ-1М
ФМ5000ФП5000ФР5000
ЭУ5001