K514 unit load supplied device installation U5052. Provides a controlled single-phase AC and rectified DC voltage and current, measurement of the temporal characteristics of the device under test.
Technical characteristics of the instrument K514 unit load:
The unit load K514 with its power directly from a single-phase AC voltage regulation provides step-AC load (measuring external ammeter)
a) at AC 380 V - in accordance with columns of Table 7-14. 1 only in the range 25A, 50A, 100A, 200A;
b) when a mains power supply: 220V - in conformity with the Table. 2;
 
Table 1
Rated current of the tested installation U5052
The measuring range of current
Load mode when the operating time
30min
3min
at mains voltage
 

And the resistance of the resistor in the primary circuit of the transformer load

"0 ohm"
I
U
I
U
1
2
3
4
5
6
5A
25A
6.5 A
120V
13A
117.0 In
50A
13.0 A
60V
26A
58.5 In
100A
20.0 A
38B
40A
38.0 In
200A
40.0 A
19B
80A
18.7 In
1A
10A
2A
350V
4A
375V
10A
2A
350V
4A
375V
Rated current of the tested installation U5052
The measuring range of current
Load mode when the operating time
3min
at mains voltage
220V or 380V

And the resistance of the resistor in the primary circuit of the transformer load

"20 ohm"
"70 ohm"
"200 ohm"
I
U
I
U
I
U
1
2
7
8
9
10
11
12
5A
25A
20.0 A
64.0
11.1 A
35.6 In
4.75 A
15.2 V
50A
37.5 A
30.0
20.0 A
16.0
9.0 A
7.2
100A
73.0 A
14.5
34.5 A
6.9 In
14.5 A
2.9 V
200A
130.0 A
6.5 V
66.0 A
3.3
28.0 A
1.4 V
1A
10A
4.4 A
110B
1.96 A
49B
0.78 A
19.5
10A
3.5 A
355V
2.00 A
248B
1.00 A
140.0 In
Rated current of the tested installation U5052
The measuring range of current
Load mode when the operating time
0.5 minutes
at mains voltage
380V
220V

And the resistance of the resistor in the primary circuit of the transformer load

"0 ohm"
I
U
I
U
1
2
13
14
15
16
5A
25A
35.0 A
112B
27.8 A
89.0 In
50A
67.5 A
54B
55.0 A
44.0 In
100A
150.0 A
30B
100.0 A
20.0 In
200A
240.0 A
12B
196.0 A
9.2 V
1A
10A
10A
250V
10A
250V
10A
5A
500V
5.0 A
440B

Table 2
Rated current of the tested installation U5052
Current Limit
Load mode when the operating time
3min
0.5 minutes

And the resistance of the resistor in the primary circuit of the transformer load

"20 ohm"
"70 ohm"
"200 ohm"
"0 ohm"
I
U
I
U
I
U
I
U
5A
25A
12.0 A
37.5 In
6.2 A
19.8 In
2.75 A
8.8 V
20A
64B
50A
24.8 A
19.0 In
12.0 A
9.6
5.25 A
4.2
40A
32B
100A
45.0 A
9.0 V
21.0 A
4.2
8.50 A
1.7 V
90A
18B
200A
80.0 A
4.0 V
40.0 A
2.0 V
19.00 A
0.95 V
140A
7B
1A
10A
4.6 A
115V
2A
50B
0.73 A
19B
11.2 A
280V

The deviation from those in Table 2 of currents and voltages up to ± 25%.