AID-70M

99 999 RUB
41 999 UAH

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Apparatus AID-70M (AID70M, AID-70-M, AID 70 M , AID 70M)
 
AID-70M apparatus designed to test insulation of power cables rectified voltage and solid dielectric sinusoidal voltage frequency 50Hz.
The measurement is carried out by applying to the exposure of high-voltage direct object (up to 70kV) or AC voltage (up to 50kV), 50 Hz sine wave with the control current to the load, ranging from tens of microamps.
 
Technical characteristics of the instrument sets AID-70M:
 
The instrument is designed to operate under a canopy or in rooms with working air temperatures from -10 º C to +40 º C and a relative humidity of 80% at +20 º C and atmospheric pressure of 84.0 kPa, 106, 7kPa (630mm.rt.st.-800mm. Hg);
The instrument unit AID-70M provides the intermittent mode;
The device provides a constant output voltage regulation of negative polarity (peak value) - 2kV-70kV;
The device provides output regulation voltage (rms) - 2kV-50kV;
Basic relative error of voltage measurement device unit AID-70M:
- Ranging from 10kV to 70kV DC - does not exceed ± 3%;
- In the range of 10 kV to 50 kV AC - does not exceed ± 3%;
{0}Note{/0}{1}. {/1} The minimum output voltage of the device unit AID-70M ± 1kV 1kV. Its value is determined by the design of the auto-installed in the control panel;
The maximum operating DC system (RMS):
- In the range of voltages from 60 kV to 2 kV - 10 mA;
- In the range of voltages from 60 kV to 70kV - 5mA;
The maximum output power of the device unit AID-70M - 0.6 kVA;
Maximum battery unit in constant current mode - 10 minutes;
Minimum Off time machine device AID-70M - 5 minutes;
Rated working AC system (RMS) in the range from 2 kV to 50 kV - 20 mA;
The maximum time of the device unit AID-70M in AC mode - 1 hour;
Minimum Off time machine - 5 minutes;
Maximum working AC system (RMS) in the range from 2 kV to 40 kV - 50 mA;
The maximum time of the device unit AID-70M in AC mode is:
- When the power delivered to a load of 1.8 kW to 2.0 kW - 1 minute;
- When the power delivered to a load of 1.5 kW to 1.8 kW - 5 minutes;
- When the power delivered to a load of 1.0 kW to 1.5 kW - 10 minutes;
- When the power supplied to the load, up to 1.0 kW - 1 hour;
Basic reduced error of the instrument unit AID-70M Current measurement does not exceed:
- On the main DC current 10mA and 20mA AC - ± 5%;
- On the main AC current from 20mA to 50mA - ± 10%;
- For additional DC current of 1mA and AC 5mA - ± 10%;
The maximum active power consumed by the device apparatus AID-70M from the mains - not more than 2.2 kW;
While ready-to-high voltage (time from the moment the power switch to power on high voltage) - no more than 20 s;
The device has a safety device to disable the high voltage when the output:
- DC voltage value (peak value) - from 70.1 kV to 74.0 kV;
- AC voltage value (rms) - from 50.1 kV to 53.0 kV;
- DC value (current value) - from 10.1 mA to 12.0 mA
- AC values ​​(RMS) - from 50.1 mA to 54.0 mA
Dimensions of various components of the apparatus of AID-70M, not more:
- Remote Control - 415h220h345mm;
- High voltage generator - 390h346h682mm;
Weight of various components of the apparatus of AID-70M, not more:
- Remote Control - 15 kg;
- High voltage generator - 36kg;
Average service life of the device - not less than 10 years;