Radiometric devices >> frequency counters, synthesizers, frequency standards >> frequency counters Ch3

Ch3-10

30 000 RUB   |   8 200 UAH   |  available: 2 pieces
    Receiver comparator Ch3-10 (Ch3 10, Ch310, Ch3-10, Ch 3 10, Ch-3-10, Ch3-10, Ch3 10, Ch310)
    Receiver comparator Ch3-10 - a device used to measure the frequency of continuous and pulse-modulated signals.
    Power - AC 220V ± 22V, 50Hz ± 1Hz.
More info ...

Ч3-101

Частотомер электронный цифровой ЧЗ-101
More info ...

Ch3-22

69 999 RUB   |   28 000 UAH   |  available: 3 pieces
Ch3-22 device image.
    Ch3-22 digital frequency and period meter is used for automatic measurement of frequency, period, frequency ratio, counting the number of electric oscillations with frequencies and issuing information to the register.
    Frequency measuring range - 10 Hz to 12 MHz.
    The range of frequencies in the measurement period - from 0 to 100 kHz.
    Frequency range of the summation - 10 Hz to 12 MHz.

More info ...

Ch3-24

16 500 RUB   |   4 000 UAH   |  available: 3 pieces
Ch3-24 device image.
    Ch3-24 frequency counter electron-counting is designed to measure frequency, period and frequency ratio electro vibrations for an arbitrarily chosen time.
    One-line digital display with memory and access to the recording device.
    Measuring range frequency sinusoidal signals - from 10 Hz to 50 MHz.
    The range of frequencies in the measurement period, - from 0 to 1 MHz.
    Frequency measure Ch3-24 has a remote control.

More info ...

CH3-32

17 499 RUB   |   6 999 UAH   |  available: 4 pieces
Q3-32 frequency counter electronic computer.
Frequency CH3-32 electron-counting (CH332, CH3 32, CH-332, CH 332, CH-3-32)
Measurement frequency range - 10Hz-3MHz (0.12 GHz-4 GHz with power YAZCH-51);
The range of frequencies in the measurement period - 10Hz-100kHz;
The range of measured time intervals - 10 -5 10 -2 s;
The instability of crystal frequency up to 1 day - ± 6 ∙ 10 -6.

More info ...

CH3-33

17 499 RUB   |   6 999 UAH   |  available: 9 pieces
Ch3-33 device image.
Frequency CH3-33 electron-counting (CH333, CH3 33, CH-333, CH 333, CH-3-33)
Designed to measure the frequency difference between the frequencies, frequency ratio, speed, time, number of pulses for any period of time;
Measurement frequency range - 10Hz-10MHz;
Input voltage - 0.1V-100V;
The range of measured time intervals - 10 -6 to-100c.

More info ...

Ch3-34

17 499 RUB   |   6 999 UAH   |  available: 10 pieces
Ch3-34 device image.
     Frequency Ch3-34 electron-counting (Ch334, Ch3 34, Ch-334, Ch 334, Ch-3-34)
     Measurement frequency range - 10Hz-120MHz (0.12 GHz, 4 GHz with power YaZCh-51);
     The range of frequencies in the measurement of the period - 0.1 Hz to 100 kHz;
     The range of measured time intervals - 10-7C-102c;
     Instability crystal frequency up to 1 day - ± 5 ∙ 10-9.

More info ...

Ch3-34A

17 499 RUB   |   6 999 UAH   |  available: 8 pieces
Ch3-34A frequency counter electronic computer.
    Frequency counter Ch3-34A electron-counting for automatic measurement of frequency of oscillations, the period of oscillations, the time interval of the frequency ratio, the issuance of coded signals measurements.
    Measurement frequency range - 10 Hz - 120 MHz (0.12 GHz - 4 GHz with power YAZCH-51).
    The range of frequencies in the measurement period - 0.01 Hz - 100 kHz.
    The range of measured time intervals - 7.10s - 102s.
    Measurement range of the frequency ratio - (10 Hz - 20 MHz) / (0.01 Hz - 100 kHz).
More info ...

Ch3-35

17 499 RUB   |   6 999 UAH   |  available: 4 pieces
Ch3-35A frequency counter image.
    Frequency counter Ch3-35 electron-counting for automatic measurement of frequency of oscillations, the period of oscillations, time interval, pulse width, frequency ratio, the issuance of coded signals measurements, outputting signals kvartsovannyh frequencies from 0.1 MHz to 10 MHz decadal steps.
    Measurement frequency range - 10 Hz - 50 MHz.
    The range of frequencies in the measurement period - 0.01 Hz - 100 kHz.
    The range of measured time intervals - 10-6 - 102.
    The range of measured time intervals - 10-6 - 102.
More info ...

Ch3-35A

17 499 RUB   |   6 999 UAH   |  available: 6 pieces
Ch3-35A frequency counter image.

    Frequency counter Ch3-35A electron-counting for automatic measurement of frequency of oscillations, the period of oscillations, time interval, pulse width, frequency ratio, issue of coded signals measurements, outputting signals quartz frequency of 0.1 MHz to 10 MHz decadal steps.
    Measurement frequency range - 10 Hz - 50 MHz.
    The range of frequencies in the measurement period - 0.01 Hz - 100 kHz.
    The range of measured time intervals - 10-6 - 102.
    The range of measured time intervals - 10-6 - 102.


More info ...
Pages: 1 2 3 4 5 6    View all
Ч3-81/1Ч3-84/2Ч3-87
Ч3-5Ч3-89Ч3-86
Ч3-86АЧ3-81Ч3-51
Ч3-61Ч3-50Ч3-52
Ч3-47Ч3-58Ч3-62
Ч3-70Ч3-71Ч3-75
Ч3-83/1Ч3-83Ч3-7
CH3-32CH3-33CH3-47A
CH3-49Ch3-10Ch3-22
Ch3-24Ch3-34Ch3-34A
Ch3-35Ch3-35ACh3-44
Ch3-45Ch3-66Ч3-101
Ч3-36Ч3-38Ч3-46
Ч3-54Ч3-57Ч3-63
Ч3-63/1Ч3-64Ч3-64/1
Ч3-65Ч3-67Ч3-68
Ч3-69Ч3-79Ч3-84
Ч3-87/1Ч3-87/2Ч3-88


Яндекс цитирования