Electrical measuring instruments >> transformers industrial >> current transformers >> 0,66kV voltage class

TNSH-0,66

116 820 RUB   |   140 184 UAH
TNSH-0,66 transformer image.
Current transformer TNSH-0,66 (TNSH0,66, TNSH 0,66)
Designed for signal measurement information instrumentation in plants AC 50Hz or 60Hz with rated voltage up to 0.66 kV;
Accuracy class - 10P;
Number of windings - 1;
Rated primary current - 15000A, 25000A;
Maximum operating current primary - 2000A, 3200A, 4000A, 5000A;
Rated secondary current - 5A.

More info ...

TNShL-0,66

available: 2 pieces
ТНШЛ-0,66 transformer image.

TNShL-0,66 current transformer is designed to transmit a signal measuring instrument measurement information, protection, automation, signaling and control electrical circuits, AC 50 Hz with a nominal voltage of 0.66 kV.

Rated primary current - from 150 A to 8000 A.


More info ...

TNSHL-0,66 (150A-500A)

5 841 RUB   |   7 009 UAH
TNSHL-0,66 (150A-500A) transformer image.
Current transformer TNSHL-0,66 (150A-500A) (TNSHL0,66, TNSHL 0,66)
Designed for signal measurement information instrumentation in plants AC 50Hz with rated voltage up to 0.66 kV;
Accuracy class - 0,5; 0,5 S, 0,2; 0,2 S, 1, 10P;
Number of windings - 1;
Rated primary current - 150A, 200A, 300A, 400A, 500A;
Maximum operating primary current - 320A, 400A, 630A, 800A, 1000A, 1600A, 2000A, 2500A;
Rated secondary current - 1A, 5A.

More info ...

TNSHL-0,66 (3000A-6000A)

14 262 RUB   |   17 114 UAH
TNSHL-0,66 (3000A-6000A) transformer image.
Current transformer TNSHL-0,66 (3000A-6000A) (TNSHL0,66, TNSHL 0,66)
Designed for signal measurement information instrumentation in plants AC 50Hz with rated voltage up to 0.66 kV;
Accuracy class - 0,5; 0,5 S, 0,2; 0,2 S, 1, 10P;
Number of windings - 1;
Rated primary current - 3000A, 4000A, 5000A, 6000A;
Maximum operating primary current - 320A, 400A, 630A, 800A, 1000A, 1600A, 2000A, 2500A;
Rated secondary current - 1A, 5A.

More info ...

TNSHL-0,66 (600A-2000A)

4 365 RUB   |   5 237 UAH
TNSHL-0,66 (600A-2000A) transformer image.
Current transformer TNSHL-0,66 (600A-2000A) (TNSHL0,66, TNSHL 0,66)
Designed for signal measurement information instrumentation in plants AC 50Hz with rated voltage up to 0.66 kV;
Accuracy class - 0,5; 0,5 S, 0,2; 0,2 S, 1, 10P;
Number of windings - 1;
Rated primary current - 150A, 200A, 300A, 400A, 500A;
Maximum operating primary current - 320A, 400A, 630A, 800A, 1000A, 1600A, 2000A, 2500A;
Rated secondary current - 1A, 5A.

More info ...

TNSHL-0,66 (600A-2500A)

5 841 RUB   |   7 009 UAH
TNSHL-0,66 (600A-2500A) transformer image.
Current transformer TNSHL-0,66 (600A-2500A) (TNSHL0,66, TNSHL 0,66)
Designed for signal measurement information instrumentation in plants AC 50Hz with rated voltage up to 0.66 kV;
Accuracy class - 0,5; 0,5 S, 0,2; 0,2 S, 1, 10P;
Number of windings - 1;
Rated primary current - 600A, 800A, 1000A, 1500A, 2000A, 2500A;
Maximum operating primary current - 320A, 400A, 630A, 800A, 1000A, 1600A, 2000A, 2500A;
Rated secondary current - 1A, 5A.

More info ...

TNSHL-0,66 (8000A-10000A)

76 258 RUB   |   91 506 UAH
TNSHL-0,66 (8000A-10000A) transformer image.
Current transformer TNSHL-0,66 (8000A-10000A) (TNSHL0,66, TNSHL 0,66)
Designed for signal measurement information instrumentation in plants AC 50Hz with rated voltage up to 0.66 kV;
Accuracy class - 3, 10P;
Number of windings - 1;
Rated primary current - 8000A, 10000A;
Maximum operating primary current - 320A, 400A, 630A, 800A, 1000A, 1600A, 2000A, 2500A;
Rated secondary current - 1A, 5A.

More info ...

TOP 0,66 B

Current transformer TOP 0.66 B.
Current Transformer TOP 0,66 B (TOP0,66B, TOP-0,66-B, TOP 0,66 B, TOP-0,66B, TOP0,66 B, TOP0,66-B)
Applied to the measuring instruments (ammeter, power meter, phase meter, meters) set to a frequency of 50 Hz alternating current with a nominal voltage to 0.66 kV. They are also used in the measurement circuit low voltage devices of buildings and structures, patterns of transmission and distribution of electricity, including those in other products;
Rated primary current - 300A, 400A, 500A, 600A, 750A, 800A, 1000A, 1200A, 1500A, 2000A.

More info ...

TOP-0,66

737 RUB   |   185 UAH   |  available: 24 pieces
Current transformer TOP 0.66.
Current transformer TOP-0,66 (TOP0,66, TOP 0,66)
Designed for signal measurement information instrumentation in plants AC 50Hz or 60Hz with rated voltage up to 0.66 kV;
Accuracy class - 0,5; 0,5 S, 0,2; 0,2 S, 1;
Number of windings - 1;
Rated primary current - 1A, 5A, 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A, 200A;
Rated secondary current - 1A, 5A;
Rated secondary burden - 1V-5V · A · A · A or 10V (for accuracy class 1).

More info ...

TOP-0,66-I

737 RUB   |   185 UAH   |  available: 24 pieces
TOP-0,66-I transformer scheme.
Current transformer TOP-0,66-I (TOP-0,66-1, TOP0,66I, TOP 0,66 I, TOP0,66-I, TOP0,66 I, TOP-0,66I, TOP 0,66I)
Designed for signal measurement information instrumentation in plants AC 50Hz or 60Hz with rated voltage up to 0.66 kV;
Accuracy class - 0,5; 0,5 S, 0,2; 0,2 S, 1;
Number of windings - 1;
Rated primary current - 1A, 5A, 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A;
Rated secondary current - 1A, 5A.

More info ...
Pages: 1 2    View all
TNSH-0,66TNSHL-0,66 (150A-500A)TNSHL-0,66 (3000A-6000A)
TNSHL-0,66 (600A-2000A)TNSHL-0,66 (600A-2500A)TNSHL-0,66 (8000A-10000A)
TNShL-0,66TOP 0,66 BTOP-0,66
TOP-0,66-ITSHL-0,66TSHL-0,66-I
TSHL-0,66-IITSHL-0,66-II-1TSHL-0,66-III-1
TSHL-0,66-III-2TSHL-0,66-III-3TSHP-0,66
TSHP-0,66-I  