Electrical measuring instruments >> transformers industrial >> current transformers >> 0,66kV voltage class

TSHL-0,66-III-1

1 431 RUB
1 717 UAH

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Current transformer TSHL-0,66-III-1 (TSHL-0,66-3-1, TSHL-0,66-111-1, TSHL0,66III1, TSHL 0,66 III 1, TSHL0,66-III-1, TSHL0,66 III-1, TSHL0,66III-1, TSHL 0,66III-1)
 
Current transformer TSHL-0,66-III-1 is intended to signal measurement information instrumentation installations in AC 50Hz or 60Hz with rated voltage up to 0.66 kV.
 
Technical characteristics of the instrument current transformers TSHL-0,66-III-1:
 
Accuracy class - 0,5; 0,5 S, 0,2 S, 1;
Number of windings - 1;
Rated current of the CT device TSHL-0,66-III-1 - 100A, 150A, 200A, 250A, 300A, 400A, 500A, 600A;
Highest voltage - 0.8 kV;
Rated secondary current of the current transformer unit TSHL-0,66-III-1 - 1A, 5A;
Rated primary current, rated secondary current, rated secondary burden and accuracy class of the instrument current transformer TSHL-0,66-III-1 are listed in Table 1;
 
Table 1 Rated primary current, rated secondary current, rated secondary burden and accuracy class of the instrument current transformer TSHL-0,66-III-1
 
rated primary current, A
Rated secondary current, A
Rated secondary burden, VA
Accuracy class
100A, 150A
1A, 5A
1, 2, 2.5, 3
0,5; 0,5 S
200A, 250A
1, 2, 2.5, 3, 5
0,5; 0,5 S
250A
1, 2, 2.5, 3
0,2 S
300A
1, 2, 2.5, 3, 5
0,5; 0,5 S; 0,2 S
10
1
400A
1, 2, 2.5, 3, 5
0,5; 0,5 S; 0,2 S
10
0.5
500A
1, 2, 2.5, 3, 5
0,5; 0,5 S; 0,2 S
10:15
0.5
600A
5A
1, 2, 2.5, 3, 5, 10
0,5; 0,5 S; 0,2 S
15-20
0.5
 
The housing CT TSHL-0,66-III-1 is made ​​of self-extinguishing hard inflammable materials;
The transformers are manufactured in execution "UHL2" and "T2", are designed to operate under the following conditions:
Height above the sea level - no more than 1000 m.
Ambient temperature
- In operation - from -60 ° C to +40 ° C ("UHL2»), -10 ° C to +50 ° C ("T2");
- Environment explosive, without dust, reactive gases and vapors in concentrations destroy metal and insulation;
- Working position - any;
Warranty period - 8 years from the date of entry into operation of the transformer, but not more than 8.5 years from the date of shipment from the factory;
The warranty applies to devices CT TSHL-0,66-III-1, after January 1, 2005;
Service life - 30 years;
Devices CT TSHL-0,66-III-1 set of protective transparent cover for separate sealing of secondary findings;
In transformers may be used to account for the secondary windings, accuracy classes 0,2 S and 0,5 S with the value of the secondary load below 25% of nominal;
Minimum permissible load current transformer unit TSHL-0,66-III-1 for winding precision class 0,2 S and 0,5 S is 1B · A;
The certificate on the current transformers with secondary windings for accounting accuracy classes 0,2 S and 0,5 S indicates the measured current and the angular error at rated secondary burden 1B · A;
 
Figure 1 Dimensions of the device current transformer TSHL-0,66-III-1
 
TSHL-0,66-III-1 - Current transformer - Drawing.
 
Weight - 0.8 kg;
The manufacturer guarantees that the quality of the instrument current transformer TSHL-0,66-III-1 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.

Photos: TSHL-0,66-III-1

TSHL-0,66-III-1 transformer image.
TSHL-0,66-III-1 transformer image.
TSHL-0,66-III-1 transformer scheme.
TSHL-0,66-III-1 transformer scheme.


Яндекс цитирования