Electrical measuring instruments >> transformers industrial >> current transformers >> 0,66kV voltage class

TSHL-0,66-III-2

4 366 RUB
5 239 UAH

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Current transformer TSHL-0,66-III-2 (TSHL-0,66-3-2, TSHL-0,66-111-2, TSHL0,66III2, TSHL 0,66 III 2, TSHL0,66-III-2, TSHL0,66 III-2, TSHL0,66III-2, TSHL 0,66 III-2)
 
Current transformer TSHL-0,66-III-2 is designed for signal transmission measurement data measuring instruments in installations AC 50Hz or 60Hz with rated voltage up to 0.66 kV.
 
Technical characteristics of the instrument current transformers TSHL-0,66-III-2:
 
Accuracy class - 0,5; 0,5 S, 0,2 S, 1;
Number of windings - 1;
Rated current of the CT device TSHL-0,66-III-2 - 300A, 400A, 500A, 600A, 750A, 800A, 1000A, 1200A, 1500A, 2000A, 2500A;
Highest voltage - 0.8 kV;
Rated secondary current of the current transformer unit TSHL-0,66-III-2 - 1A, 5A;
Rated primary current, rated secondary current, rated secondary burden and accuracy class of the instrument current transformer TSHL-0,66-III-2 are given in Table 1;
 
Table 1 Rated primary current, rated secondary current, rated secondary burden and accuracy class of the instrument current transformer TSHL-0,66-III-2
 
rated primary current, A
Rated secondary current, A
Rated secondary load, VA
Accuracy class
300A, 400A
1A, 5A
1, 2, 2.5, 3
0,5; 0,5 S
10
1
500A, 600A
1, 2, 2.5, 3, 5, 10
0,5; 0,5 S; 0,2 S
15
1
750A
1, 2, 2.5, 3, 5, 10, 15
0,5; 0,5 S; 0,2 S
20, 30
1
800A
1, 2, 2.5, 3, 5, 10, 15
0,5; 0,5 S; 0,2 S
20
0.5
1000A, 1200A, 1500A
1, 2, 2.5, 3, 5, 10, 15
0,5; 0,5 S; 0,2 S
20, 30
0.5
2000A, 2500A
5A
1, 2, 2.5, 3, 5, 10, 15, 20
0,5; 0,5 S; 0,2 S
30
0,5; 0,5 S
 
The housing CT TSHL-0,66-III-2 is made ​​of self-extinguishing hard inflammable materials;
The transformers are manufactured in execution "UHL2" and "T2", are designed to operate under the following conditions:
Height above the sea level - no more than 1000 m.
Ambient temperature
- In operation - from -60 ° C to +40 ° C ("UHL2»), -10 ° C to +50 ° C ("T2");
- Environment explosive, without dust, reactive gases and vapors in concentrations destroy metal and insulation;
- Working position - any;
Warranty period - 8 years from the date of entry into operation of the transformer, but not more than 8.5 years from the date of shipment from the factory;
The warranty applies to devices TSHL-0,66-III-2, after January 1, 2005;
Service life - 30 years;
Devices TSHL-0,66-III-2 set of protective transparent cover for separate sealing of secondary findings;
In transformers may be used to account for the secondary windings, accuracy classes 0,2 S and 0,5 S with the value of the secondary load below 25% of nominal;
Minimum permissible load current transformer unit TSHL-0 ,66-III-2 for winding precision class 0,2 S and 0,5 S is 1B · A;
The certificate on the current transformers with secondary windings for accounting accuracy classes 0,2 S and 0,5 S indicates the measured current and the angular error at rated secondary burden 1B · A;
 
Figure 1 Dimensions of the device current transformer TSHL-0,66-III-2
 
TSHL-0,66-III-2 - Current transformer - Drawing.
 
Weight - 2.0 kg;
The manufacturer guarantees that the quality of the instrument current transformer TSHL-0,66-III-2 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.

Photos: TSHL-0,66-III-2

TSHL-0,66-III-2 transformer image.
TSHL-0,66-III-2 transformer image.
TSHL-0,66-III-2 transformer scheme.
TSHL-0,66-III-2 transformer scheme.


Яндекс цитирования