Electrical measuring instruments >> combination devices

Ts4312

6 600 RUB
1 600 UAH
available:
6 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

    Combined portable device Ts4312

    Also, this device can be called: Ts 4312, Ts-4312.
 
    Ts4312 portable device combination designed to measure:
    - DC Current - from 0.3 mA to 6 A;
    - A DC voltage - from 0.075 V to 900 V;
    - AC current - from 1.5 mA to 6A;
    - Alternating voltage - from 0.3 V to 1900 V;
    - DC resistance - from 200 ohms to 3 megohms.
    Accuracy class - 1.0, 1.5.
 
    Ts4312 devices combined magneto system equipped with a movable frame on extensions. Rectifier system, semiconductor rectifiers with arrow pointer with unilateral uneven scales when measuring voltage and current, DC resistance.
 
    Specifications:
 
    Ranges - 30 ohms, 300 ohms, 3000 ohms.
    Internal voltage electrochemical power source - from 3.7 V to 4.7 V.
    Voltage of the external power source:
    - For the detection limit of 300 ohm - 11 V to 14 V;
    - The detection limit for 3000 ohm - from 120 to 160 V.

    Limits of measurement:
    - DC current - 0.3 mA, 1.5 mA, 6 mA, 15 mA, 60 mA, 150 mA, 600 mA, 1.5 A, 6 A;
    - DC - 0.075 V, 0.3 V, 1.5 V, 7.5 V, 30 V, 60 V, 150 V, 300 V, 600 V, 900 V;
    - AC power - 1.5 mA 6 mA, 15 mA, 60 mA, 150 mA, 600 mA, 1.5 A; 6A;
    - AC voltage of - 0.3 V, 1.5 V, 7.5 V, 30 V, 60 V, 150 V, 300 V, 600 V, 900 V;
    - DC resistance - 200 ohms, 3 ohms, 30 ohms, 300 ohms, 3 megohms.

    Accuracy:
    - DC current - ± 1,0%;
    - DC voltage - ± 1,0%;
    - AC power - ± 1,5%;
    - DC Resistance - ± 1,0%.
    Current full deviation when the voltage, the voltage drop at the terminals when the testers Ts4312 current and power consumption of electrochemical sources listed in Table 1.

    Table 1
Type of current
Limits of measurement
Voltage drop in
Full-scale deflection current, mA
Current consumption from electrochemical sources mA
Permanent
0.3 mA
7.5 mA
6 mA to 600 mA
0.079 In
0.3
0.65 V
-
-
-
-
-
-
Permanent
75 mV, 0.3 V, 1.5 V
from 7.5 V to 900 V
-
-
306 uA
1530 uA
-
-
200 ohms
3 k
30 kilohms
300 ohms
3 megohms
-
-
-
-
-
-
-
-
-
-
22 mA
20 mA
2 mA
0.7 mA
0.8 mA
Variable (normal range of frequencies)
from 1.5 mA to 600 mA
0.3
1.5
from 7.5 V to 900 V
0.65 V
-
-
-
-
5075 uA
1030 uA
1545 uA
-
-
-
-

    Frequency range of the tester indicated in Table 2.

    Table 2
Ranges
Frequency range, Hz
normal
Working
1.5 mA to 6000 mA
from 0.3 V to 30 V
from 60 V to 300 V
from 600 V to 900 V
45 Hz to 60 Hz
from 60 Hz to 10,000 Hz
from 60 Hz to 10,000 Hz
from 60 Hz to 2000 Hz
from 60 Hz to 1000 Hz
    Time for reading devices - no more than 4 seconds.
    Dimensions - 225x295x125 mm.
    Weight of the device combined - 4.0 kg.

    Operating Conditions instruments testers Ts4312:
 
    Ambient temperature - +10 ° C to +40 ° C.
    Relative humidity at +25 ° C - 80%.
    Atmospheric pressure - from 86 kPa to 106 kPa (650 mm Hg. Art. 800 mm Hg. Tbsp.)

Photos: Ts4312

Ts4312 device image.
Ts4312 device image.
Ts4312 view panel of the device.
Ts4312 view panel of the device.
Ts4312 side view.
Ts4312 side view.
Ts4312 side view.
Ts4312 side view.
Ts4312 side view.
Ts4312 side view.
Ts4312 bottom view.
Ts4312 bottom view.


Яндекс цитирования