Wattmeter TS1428, TS1428 varmeter (TS-1428, TS 1428)

Wattmeter TS1428, TS1428 varmeter designed for measurement of active and reactive power in three-phase systems of ship power plants, 50 Hz and 400 Hz.
Vibration-proof, shock-proof.
Technical characteristics of the devices wattmeters TS1428, TS1428 varmeter:
- Ambient temperature from -40 º C to +55 º C;
- Relative humidity up to 100% at 50 º C;
- Measuring range, rated current and voltage, ways to connect the device TS1428 username in Table 1-3;
Nominal Power Factor cosφ - 1,0;
Nominal Power Factor sinφ - 1,0;
Rated frequency - 50 Hz and 400 Hz (Table 1-4), 50 Hz (Table 1-4);
 
Table 1. Wattmeters from zero at the edge of the measuring range
Rated current
Rated voltage
127V
220V
380V
Measurement range
5A
0kVt-1KW
0kVt-2kW
0kVt-3kW
10A
0kVt-2kW
0kVt-4kW
0kVt-6kW
20A
0kVt-4kW
0kVt-8kW
0kVt-12kW
30A
0kVt-6kW
0kVt-12kW
0kVt-20kW
50A
0kVt-10kW
0kVt-20kW
0kVt-30kW
75A
0kVt-15kW
0kVt-30kW
0kVt-50kW
100A
0kVt-20kW
0kVt-40kW
0kVt-60kW
150A
0kVt-30kW
0kVt-60kW
0kVt-100kW
200A
0kVt-40kW
0kVt-80kW
0kVt-120kW
300A
0kVt-60kW
0kVt-120kW
0kVt-200kW
400A
0kVt-80kW
0kVt-150kW
0kVt-250kW
600A
0kVt-120kW
0kVt-250kW
0kVt-400kW
750A
0kVt-150kW
0kVt-300kW
0kVt-500kW
800A
0kVt-150kW
0kVt-300kW
0kVt-500kW
1000A
0kVt-200kW
0kVt-400kW
0kVt-600kVt
1500A
0kVt-300kW
0kVt-600kVt
0kVt-1000 kW
2000A
0kVt-400kW
0kVt-800kW
0kVt-1200kVt
3000A
0kVt-600kVt
0kVt-1200kVt
0kVt-2000kW
4000A
0kVt-800kW
0kVt-1500 kW
0kVt-2500kVt
5000A
0kVt-1000 kW
0kVt-2000kW
0kVt-3000kVt
6000A
0kVt-1200kVt
0kVt-2500kVt
0kVt-4000kVt
8000A
0kVt-1500 kW
0kVt-3000kVt
0kVt-5000kVt
10000A
0kVt-2000kW
0kVt-4000kVt
0kVt-6000kVt

Table 2. Wattmeters from zero at the edge of the measuring range
Rated current
Rated voltage
127V
220V
380V
Measurement range
5A
0.15 kW-0kVt-1KW
0.3 kW, 2 kW, 0kVt
0.5kW-3kW-0kVt
10A
0.3 kW, 2 kW, 0kVt
0.6 kW, 4 kW 0kVt
1kW-0kVt-6kW
20A
0.6 kW, 4 kW 0kVt
0.2 kW-0kVt-8kW
2KW-12KW-0kVt
30A
1kW-0kVt-6kW
2KW-12KW-0kVt
3kW-20kW-0kVt
50A
1.5 kW-10 kW 0kVt
3kW-20kW-0kVt
5KW-30KW-0kVt
75A
2.5kW-15kW-0kVt
5KW-30KW-0kVt
8kW, 50kW-0kVt
100A
3kW-20kW-0kVt
0kVt-6kW-40kW
10kW-60kW-0kVt
150A
5KW-30KW-0kVt
10kW-60kW-0kVt
15kW-100kW-0kVt
200A
0kVt-6kW-40kW
12kW-80kW-0kVt
20kW-120kW-0kVt
300A
10kW-60kW-0kVt
20kW-120kW-0kVt
30kW-200kW-0kVt
400A
12kW-80kW-0kVt
25kW-150kW-0kVt
40kW-250kW-0kVt
600A
20kW-120kW-0kVt
40kW-250kW-0kVt
60kW-400kW-0kVt
750A
25kW-150kW-0kVt
50kW-300kW-0kVt
80kW-500kW-0kVt
800A
25kW-150kW-0kVt
50kW-300kW-0kVt
80kW-500kW-0kVt
1000A
30kW-200kW-0kVt
60kW-400kW-0kVt
100kW-0kVt-600kVt
1500A
50kW-300kW-0kVt
100kW-0kVt-600kVt
150kW-0kVt-1000 kW
2000A
60kW-400kW-0kVt
120kW-800kW-0kVt
200kW-0kVt-1200kVt
3000A
100kW-0kVt-600kVt
200kW-0kVt-1200kVt
300kW-2000kW-0kVt
4000A
120kW-800kW-0kVt
250 kW, 1500 kW, 0kVt
400kW-0kVt-2500kVt
5000A
150kW-0kVt-1000 kW
300kW-2000kW-0kVt
500kW-0kVt-3000kVt
6000A
200kW-0kVt-1200kVt
400kW-0kVt-2500kVt
600kVt-0kVt-4000kVt
8000A
250 kW, 1500 kW, 0kVt
500kW-0kVt-3000kVt
800kW-0kVt-5000kVt
10000A
300kW-2000kW-0kVt
600kVt-0kVt-4000kVt
1000 kW-0kVt-6000kVt


Table 3. Measurement ranges varmeter

Rated current
Rated voltage
127V
220V
380V
Measurement range
5A
0.5 quartz-0kvar 1kvar
1kvar-0kvar-2kvar
1.5 quartz-0kvar 3kvar
10A
1kvar-0kvar-2kvar
2kvar-0kvar-4kvar
3kvar-0kvar-6kvar
20A
2kvar-0kvar-4kvar
4kvar-0kvar-8kvar
6kvar-0kvar-12kvar
30A
3kvar-0kvar-6kvar
6kvar-0kvar-12kvar
10kvar-0kvar-20kvar
50A
5kvar-0kvar-10kvar
10kvar-0kvar-20kvar
15kvar-0kvar-30kvar
75A
8kvar-0kvar-15kvar
15kvar-0kvar-30kvar
25kvar-0kvar-50kvar
100A
10kvar-0kvar-20kvar
20kvar-0kvar-40kvar
30kvar-0kvar-60kvar
150A
15kvar-0kvar-30kvar
30kvar-0kvar-60kvar
50kvar-0kvar-100kvar
200A
20kvar-0kvar-40kvar
40kvar-0kvar-80kvar
60kvar-0kvar-120kvar
300A
30kvar-0kvar-60kvar
60kvar-0kvar-120kvar
100kvar-0kvar-200kvar
400A
40kvar-0kvar-80kvar
80kvar-0kvar-150kvar
120kvar-0kvar-250kvar
600A
60kvar-0kvar-120kvar
120kvar-0kvar-250kvar
200kvar-0kvar-400kvar
750A
80kvar-0kvar-150kvar
150var-0kvar-300kvar
250kvar-0kvar-500kvar
800A
80kvar-0kvar-150kvar
150kvar-0kvar-300kvar
250kvar-0kvar-500kvar
1000A
100kvar-0kvar-200kvar
200kvar-0kvar-400kvar
300kvar-0kvar-600kvar
1500A
150kvar-0kvar-300kvar
300kvar-0kvar-600kvar
500kvar-0kvar-1000kvar
2000A
200kvar-0kvar-400kvar
400kvar-0kvar-800kvar
600kvar-0kvar-1200kvar
3000A
300kvar-0kvar-600kvar
600kvar-0kvar-1200kvar
1000kvar-0kvar-2000kvar
4000A
400kvar-0kvar-800kvar
800kvar-0kvar-1500kvar
1200kvar-0kvar-2500kvar
5000A
500kvar-0kvar-1000kvar
1000kvar-0kvar-2000kvar
1500kvar-0kvar-3000kvar
6000A
600kvar-0kvar-1200kvar
1200kvar-0kvar-2500kvar
2000kvar-0kvar-4000kvar
8000A
800kvar-0kvar-1500kvar
1500kvar-0kvar-3000kvar
2500kvar-0kvar-5000kvar
10000A
1000kvar-0kvar-2000kvar
2000kvar-0kvar-4000kvar
3000kvar-0kvar-6000kvar

Table 4. Measuring ranges for the rated voltage wattmeter 690V and 6300V
Rated voltage
Nomination
flaxes current
Measurement range
Connecting the parallel circuits
Connection of successive chains
690V
3000A
0.5 MW-3 MW-0MVt
Transformer voltage 690/127 or 660/127
Through current transformers secondary winding on the transformer 5A and 5/1
6300V
300A
0.5 MW-3 MW-0MVt
Voltage transformer 6300/127 or 6300/100
500A
0.8 MW-0, 5 MW

- Power consumption of each series circuit and wattmeter varmeter at rated current and rated frequency not exceeding 5V ∙ A;
- Power consumption of each branch circuit and wattmeter varmeter at rated current and rated frequency not exceeding 5V ∙ A;
- Maximum permissible error is ± 2,5% of the length of the scale;
- The limit of additional error TS1428 caused by:
- Changes in the ambient temperature of the normal 20 º C ± 5 º C to any temperature from -40 º C to +55 º C for every 10 º C of temperature change is equal to ± 1,25%;
- Changes in the supply voltage by ± 20% of nominal is ± 2,5%;
- Changes in the operating position (tilt) of the device TS1428 from normal in any direction up to 45 º, is ± 1%;
- Basic and additional errors are normalized, excluding errors of measuring current and voltage transformers, and are expressed as a percentage of the final value of the measuring range, and for wattmeters and varmeter with double-sided scale - of the modules of finite values ​​range;
- Dielectric strength between the measuring circuit and the housing and the power meter indicating instrument varmeter and additional electric circuit device and its case - 1.5 kV;
- Insulation resistance of electrical circuits indicating instrument relative to the housing and the additional device and its case - 20 MW;
- Response time showing the device is less than 3 seconds;
- The length of the instrument scale TS1428 110mm ± 5mm;
- Dimensions of the indicating device - 80h80h126mm;
- Dimensions of additional devices R1818, R1818 / 1 - 160h170h144mm;
- Weight indicating instrument - no more than 1 kg;
- Weight of additional devices R1818, R1818 / 1 - no more than 3kg.

Photos TS1428

Ц1428 device image with the addition R1818 (P1818).
Ц1428 device image with the addition R1818 (P1818).
Ts1428 front view (scale).
Ts1428 front view (scale).
Ts1428 side view (casing depth).
Ts1428 side view (casing depth).
Ts1428 rear view (connection).
Ts1428 rear view (connection).
R1818 (P1818) additional device front view.
R1818 (P1818) additional device front view.
R1818 (P1818) additional device side view.
R1818 (P1818) additional device side view.
R1818 (P1818) additional device rear view.
R1818 (P1818) additional device rear view.


Яндекс цитирования