Electrical measuring instruments >> voltmeters


12 999 RUB
6 240 UAH
4 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Voltmeter S5023 (S-5023, S 5023, c-5023, c 5023, c5023)

    Voltmeter S5023 is designed to measure AC voltage in a wide range of frequencies and DC voltage. Accuracy Class 0.5 voltmeter S5023. Upper range value 150B.

Voltmeters S5023 intended to measure alternating voltage in a wide range of frequencies and DC voltage.
    Voltmeters S5023 are designed for use in moderate climate in enclosed dry heated rooms at the ambient temperature of 10 to 35 ° C and a relative humidity of 80% (at 25 ° C);
    Voltmeters S5023 T4.1 - tropical version - in dry and humid tropical climate in closed rooms with air conditioned or partially air-conditioned at the ambient temperature from 1 to 40 ° C and a relative humidity of 80% at 25 ° C and at lower temperatures no condensation (at higher temperatures, relative humidity below) in accordance with GOST 15150-69
    Technical data

    Accuracy Class 0.5 voltmeter S5023 according to GOST 8711-78. Additional error S5023 voltmeter, frequency deviation caused by the upper limit of the normal range of frequencies up to any frequency in the working frequency range does not exceed ± 0,5% of the final value of the measuring range.
Time for reading voltmeter S5023 6. Voltmeter S5023 can be used for measurements at frequencies above the work area. Frequency limits and measurement errors are shown in Table 1. Input impedance voltmeter DC S5023 more than 10 10 ohms.

Dining lighting circuit voltmeter is provided from AC power supply (220 +22), frequency 50-60Hz through a step-down transformer, can be combined with a voltmeter S5023, either on AC or DC voltage of 4 V. Dimensions: voltmeter 205h290h135 mm transformer housing - 65h85h45 mm. Weight voltmeter S5023 is not more than 4 kg transformer not more than 0.5 kg.

Table 1.

tion of the current-

The final
of range
Area measu-


tial region, Hz


ting freque-

ncy range, MHz

Frequency in MHz at the border of measurement

error in the range

Input capacita-

nce, pF, not more

sore upon Mr. GOST 9444-74
zhek, H


-0.5 to +1.5% of full scale of the measuring range


-0.5 to 2.5% of the final value of the measuring range

S502 / 3 150B 45 to 1.10 6 More than 1 to 2.5 Over 2.5 to 3.5 Over 3.5 to 5 30 0.5 0.98

Photos: S5023

S5023 voltmeter image.
S5023 voltmeter image.
S5023 panel view.
S5023 panel view.
S5023 side view (terminals, switches).
S5023 side view (terminals, switches).
S5023 side view.
S5023 side view.
S5023 side view.
S5023 side view.
S5023 bottom view.
S5023 bottom view.