N393 ammeter, voltmeter N393 (N 393, N-393, h393, h 393, h-393)
P rednaznachen measurement and continuous recording of the current and voltages are single-phase alternating current in the frequency range 45-65Hz. Devices can be made ​​to work in the normal range of frequencies 45-1000Hz with an active area of 45 to 10000 Hz.
The basic error of ± 1,5%, ± 2,5%
 

N393 ammeters, voltmeters N393 panel recorders (hereinafter - the instruments) used for measurement and continuous recording of a current and voltages are single-phase alternating current in the frequency range of 45-65 Hz. Devices can be made ​​to work in the normal frequency range 45-1000 Hz with a working area of 45 to 10,000 Hz.
Ammeter and voltmeter N393 designed for use in enclosed dry heated rooms at an ambient temperature of 0 to 50 ° C and 90% relative humidity at 25 ° C.
Ammeter and voltmeter N393 delivered to areas with tropical climates (symbol N393 TO 02.04 **), designed to operate in ambient temperatures from 0 to 50 ° C and relative humidity. 95% at 40 ° C.
Technical data
The final values ​​of the measuring range devices are given in Table 1. Limit of acceptable basic error on the measurement and recording of the measured value is equal to:
± 1,5% - for devices with a normal region of frequencies of 45-65 Hz;
± 2,5% - for devices with a normal frequency region 45-1000 Hz, the final value of the measuring range.
Limit of acceptable total error N393 devices for recording the measured value is equal to:
± 1,5% - for devices with a normal region of frequencies 45-65Hz;
± 2,5% - for devices with a normal region of frequencies 45-1000Hz, - the final value of the measuring range.
Limit of acceptable basic error on the record time is ± 0,5%. Limit of acceptable devices additional error caused by the change in ambient temperature from normal to any temperature in the range from 0 to 50 ° C, equal to the limit of acceptable basic error for every 10 ° C change.
Limit of acceptable additional error N393 devices to measure and record the measured value, due to changes in position of the device from its normal position in any direction by ± 5 °, equal to the limit of acceptable basic error.
Limit of acceptable additional error N393 devices to measure and record the measured value under the influence of an external uniform magnetic field, the sine poloidal changes in time with a frequency equal to the frequency of the current flowing through the measuring circuit of the test device, in the most unfavorable direction and phase of the magnetic field is limit of acceptable basic error. The magnetic field:
for a frequency of 50 Hz and 1000 - 0.5 mT;
for a frequency of 10,000 Hz - 0.05 mT.
Limit of acceptable additional error N393 devices to measure and record the measured value, caused by the installation. ferromagnetic shield thickness (2 ± 0,5) mm, equal to ± 0,5% of full scale range. Limit of acceptable additional error of measurement instruments and recording of measured values ​​caused by the deviation of the frequency equal to the limit of acceptable basic error when:
frequency deviation of ± 10% from the end of the normal range of frequencies - for units with a normal region of frequencies 45-65Hz;
frequency deviation from the normal limits of the frequency range up to any frequency in the working frequency range - for units with normal N393 frequency region 45-1000Hz.
Limit of acceptable additional error devices to measure and record the measured value, due to changes in supply voltage of ± 10% of nominal value equal to the limit allowed by the basic error.
Limit of acceptable additional error of measurement instruments and recording the measured value, due to the influence placed back to back with him of the same device to be located at a distance of not less than 1 m, is ± 0,5% of full scale range.
Response time unit is less than 2 s., Index value of the first flip does not exceed 7% of the width of the field recording. The drift of the zero-line appliance within 30 days of 1.5 mm. Failure to return writing device (pointer) of the device to the zero line (zero point scale) of 1.5 mm. Allowable difference of zero line indicated on the chart tape recording with the line obtained when the pointer to the zero mark of the scale, not more than 0.75 mm.
The line width of recording up to 0.7 mm. Warm-up time 1 hour. Continuous operation is not limited. Write the results produced ball pivot UPS-3-107-1 ,0-300 blue or ink ribbon diagram perforated with a nominal width of 100 mm field recording. Power device is supplied from the AC voltage (220 ± 22), frequency (50 ± 1) Hz or (60 1.2) Hz - on demand.
Power consumption is less than N393 devices:
measuring circuit - 1 V · A;
food chain - 12 V · A
Continuous recording device with a single ink tank refilling ink or one ball pivot at least 60 days. To move the chart tape applied synchronous motor powered by an AC voltage of 220V, 50Hz or 60 Hz for devices N393 is exported. Nominal values ​​of travel speed chart tape 20, 60, 180, 600, 1800, 5400 mm / h
Speed ​​change is the replacement of replacement gears. Insulation between the body and insulated from the electrical circuits of the device (except chain deposition time stamps), and isolation between separate electrical circuits under normal operating conditions is alive withstand for 1 minute. Impact of testing AC voltage frequency (50 ± 1) Hz, RMS value is: 1.5 kW - for ammeters, voltmeters, to be included in current transformers and voltmeters direct connection with finite values ​​ranges 15V, 25V, 50V, 150V, 250V.
Note. Voltmeters for direct connection with end of the measuring range of 500 and 600 V insulation between the body and the measuring chain, and between the measuring circuit and the power to withstand the test voltage 2kV.
The insulation resistance between the case and insulated from any electrical appliance chain in normal conditions of use of at least 40 MΩ.
Overall dimensions shall be 160x160x195 mm. The total overall size of the inverter 160x160x280 mm. Unit weight is not more than 4.6 kg. In accordance with the order of ammeter and voltmeter N393 comes with a record of testimony in ink or ink and ball pivot.
 
Table 1.

Device name

The final value of the measuring range

A way to incorporate

Ammeter

5mA, 15mA, 25mA, 50mA, 150mA, 250mA, 500mA

Directly

1 A, 1.5 A, 2.5 A, 5 A

1A, 5A, 10A, 15A, 20A, 30A, 40A, 50A, 75A;

Through current transformers with secondary current of 1 A or 5 A

80A, 100A, 150A, 200A, 300A, 400A;
500A, 600A, 750A, 800A

1kA; 1kA, 2ka, 1.5 kA 2ka; 3kA; 4ka

Through current transformers with secondary current 1A

1kA, 1.2 kA, 1, 5 kA 2ka; 3kA; 4ka; 5kA; 6kA; 8kA; 10kA;

Through current transformers with secondary current 5A

12kA, 15kA, 20kA, 25kA, 30kA, 40kA

Voltmeter
15V, 25V, 50V, 150V, 250V, 500V, 600V
Directly
500V, 600V, 750V

Through voltage transformers with secondary voltage 100V

4B, 7.5 V, 12 V, 5V, 15V, 20V, 25V, 40V, 150V;
200Sqr, 250kV, 400kV, 600kV

NOTE: The inclusion in current and voltage transformers are designed to work only for the normal frequency range of 45-65 Hz.