Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> narrow-profile DC

M1830K

20 656 RUB
6 885 UAH
available:
53 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
M1830K ammeter, voltmeter M1830K, microammeter M1830K, milliammeter M1830K, millivoltmeter M1830K (M 1830 K, M-1830-K, M1830-K, M1830 K, M 1830K, M-1830K)
 
M1830K ammeter, voltmeter M1830K, microammeter M1830K, milliammeter M1830K, millivoltmeter M1830K designed to measure DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
Dimensions - 240h30h295mm.
Accuracy class - 0.5.
Narrow, three-position contact.
 
Technical characteristics of the devices M1830K ammeters, voltmeters M1830K, microammeter M1830K, milliammeter M1830K, millivoltmeters M1830K:
 
They are used for measuring DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
The devices can be used to work in a set of transducers (sensors) SHGs.
Devices M1830K ammeter, voltmeter M1830K, microammeter M1830K, milliammeter M1830K, millivoltmeter M1830K designed for flush mounting on panels and boards fixed installations.
The instruments are the five modifications:
- Pointing - A;
- Signaling - C;
- Three-pin - K;
- Pin DIP with the right contact - KP;
- Pin DIP with the left contact - CR.
Devices M1830K ammeter, voltmeter M1830K, microammeter M1830K, milliammeter M1830K, millivoltmeter M1830K used to work at ambient temperatures from -30 º C to +50 ° C and relative humidity up to 90% (at 30 ° C).
Execution of regular and tropical.
Instruments issued in a tropical version, designed for operation at ambient temperature from -10 º C to +35 ° C and relative humidity of 95%.
With the direct inclusion of the instrument M1830K ammeter, voltmeter M1830K, microammeter M1830K, milliammeter M1830K, M1830K millivoltmeter circuit in time and calm the 3s limits of measurement are as follows: 50mkA-0mkA-50mkA, 0mkA-100mkA; 100mkA-0mkA-100mkA; 0mkA-150mkA; 150mkA -0mkA-150mkA; 0mkA-300mkA, 300mkA-0mkA 300mkA-and-0mkA 500mkA;
- At time 1.5 seconds outside the calming measure - 500mkA-0mkA-500mkA, 0 mA-1 mA, 1 mA, 0 mA-1 mA, 0 mA-5 mA, 0 mA-5 mA-5 mA, 0 mA-10 mA, 0 mA-10 mA-10 mA, 0 mA to 20 mA , 0 mA-20 mA to 20 mA, 0 mA-30 mA, 0 mA-30 mA-30 mA, 0 mA-50 mA, 0 mA-50 mA-50 mA, 0 mA-100mA, 100mA 100mA, 0 mA-, 0 mA-150mA, 150mA 150mA, 0 mA-, 0 mA-300mA , 0 mA-300 mA-300 mA, 0 mA-500mA, 500mA 500mA, 0 mA-, 0A-1A, 1A-0A-1A 0A-2A, 2A-0A-2A, 5A and 0A-0A-5A-5A.
When the device is turned M1830K ammeter, voltmeter M1830K, microammeter M1830K, milliammeter M1830K, millivoltmeter with an external shunt M1830K 75mV and 45mV at the time and calm the 1.5 second measurement limits are as follows: 0A-10A, 10A-0A-10A, 0A-20A, 20A -0A-20A, 0A-30A, 30A-0A-30A, 0A-50A, 50A-0A-50A, 0A-100A, 100A-100A-0s, 0s-150A, 150A-150A-0s, 0s-200A, 200A -0A-200A,-300A 0A, 0A-300A-300A, 500A-0s, 0s-500A-500A, 750A-0s, 750A-750A-0s; 0kA-1kA; 1kA-0kA-1kA; 0kA-2kA, 2kA -0kA-2kA, 0kA-3kA; 3kA-0kA-3kA; 0kA-4kA; 4kA-0kA-4kA; 0kA-5kA; 5kA-0kA-5kA; 0kA 6kA-and-6kA 0kA-6kA.
At rated current 0.2 mA and 4 seconds of time calming devices measuring range ammeter M1830K, voltmeter M1830K, microammeter M1830K, milliammeter M1830K, millivoltmeter M1830K - 0mV-10mV, 10mV, 10mV 0mV-; 0mV-20mV, 20mV, 20mV 0mV-; 0mV -45mV, 45mV, 45mV 0mV-; 0mV-50mV, 50mV, 50mV 0mV-; 0mV-100mV, 100mV, 100mV 0mV-; 0mV-200mV, 200mV, 200mV 0mV-; 0mV-500mV, 500mV, 500mV 0mV-; 0V -1V, 1V-0V-1V, 0V-1, 5V, 1.5V-0V-1, 5V, 0V-3V, 3V-0V-3V, 0V-7, 5 V, 7.5 V-0 V-7, 5B .
At rated current 1.0 mA and 1.5 seconds of time calming devices measuring range ammeter M1830K, voltmeter M1830K, microammeter M1830K, milliammeter M1830K, millivoltmeter M1830K - 0mV-75mV, 75mV, 75mV 0mV-, 0V to 10V, 10V-0V-10V , 0V-15V, 15V-0V-15V, 0V-30V, 30V-0V-30V, 0V-50V, 50V-0V-50V, 0V-75V, 75V-0V-75V, 0V-150V, 150V-150V-0V , 0V-250V, 250V-0V-250V, 0V-400V, 400V-0V-400V, 0V-600V, 600V, 600V-0V-.
Rated current millivoltmeter and voltmeter is different from the values ​​given above, no more than ± 20%.
The voltage drop across the microammeter, milliammeter and the ammeter does not exceed 120mV.
The main error types M1830KA devices, M1830KS, M1830KK, M1830KKP and M1830KKL is ± 0,5%; error trigger pin device and device types M1830KA M1830KS absent, and the devices M1830KK, M1830KKP and M1830KKL - is ± 1,0%.
The length scale devices M1830K ammeter, voltmeter M1830K, microammeter M1830K, milliammeter M1830K, millivoltmeter M1830K - 200mm.
Operating position horizontal devices.
Change the ammeter readings M1830K, voltmeter M1830K, microammeter M1830K, milliammeter M1830K, millivoltmeter M1830K caused by ambient temperature deviation from normal is less than ± 0,4% for every 10 degrees, under the influence of external magnetic field strength of 400 A / m - not more than ± 0,5%.
Weight - no more than 1.8 kg.
Devices M1830K ammeter, voltmeter M1830K, microammeter M1830K, milliammeter M1830K, millivoltmeter M1830K have a flat cast aluminum alloy, closed the lid.
Inside the case are available magnetoelectric measuring mechanism with vnutriramochnym magnet, with a moving part fixed to the inner braces, the optical system and elements of the measuring circuit.
 

Photos M1830K

M1830K front view (scale).
M1830K front view (scale).
M1830K side view (casing depth).
M1830K side view (casing depth).
M1830K rear view (connection).
M1830K rear view (connection).