Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> narrow-profile DC

M1742-M1

101 739 RUB
40 696 UAH
available:
53 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
M1742-M1 ammeter, voltmeter M1742-M1, M1742-M1 milliammeter (M 1742 M1, M-1742-M1, M1742-M1, M1742 M1, M-1742M1, M 1742M1)
 
M1742-M1 ammeter, voltmeter M1742-M1, M1742-M1 milliammeter designed to measure DC voltage and current.
Dimensions - 160h180h197mm.
Accuracy class - 1.0.
Multi-channel narrow-profile.
 
Technical characteristics of the instrument ammeters M1742-M1, voltmeters, M1742-M1, M1-M1742 milliammeter:
 
Instruments used to measure identical parameters and are intended primarily for use with transducers (sensors), GSP, having outputs DC.
Instruments M1742-M1 ammeter, voltmeter M1742-M1, M1742-M1 milliammeter have color filters, through which in the case of deviations of monitored parameters outside the preset range of the light color of the pointer changes, thus signaling a violation occurs.
Instruments used in ambient temperatures from -30 º C to +50 ° C and relative humidity from 30% to 80% (over temperature) and relative humidity up to 90% (at 30 ° C).
Instruments M1742-M1 ammeter, voltmeter M1742-M1, M1742-M1 milliammeter produced in tropical version, designed for operation at ambient temperatures from -10 º C to +55 ° C and relative humidity of 95% (M1742-M1T).
In terms of resistance to mechanical impact devices are common.
Instruments M1742-M1 ammeter, voltmeter M1742-M1, M1742-M1 milliammeter have 12 channels.
Measuring range:
- Milliammeter - 0 mA-1 mA, 1 mA, 0 mA-1 mA, 0 mA-5 mA, 0 mA-5 mA-5 mA, 0 mA to 20 mA, 0 mA-20 mA to 20 mA;
- Voltmeter - 0V-1V, 1V-0V-1V, 1V-10V, 10V-0V-10V.
Class of accuracy of the instrument - 1.0.
Change the readings M1742-M1 ammeter, voltmeter M1742-M1, M1742-M1 milliammeter caused by ambient air temperature deviation from the normal (within the operating temperature) does not exceed ± 0,8% for every 10 deg, when the instrument is in a ferromagnetic shield 3mm thick - does not exceed ± 1% full scale (for devices with two-sided scale - the amount of full scale value).
Settling time voltmeters in the range of 0V-1V, 1V-0V-1V less than 3 seconds, in other bands - 2 sec.
Unit weight - 2.0 kg.
Instruments M1742-M1 ammeter, voltmeter M1742-M1, M1742-M1 milliammeter consist of die-cast casing with attached to it by one unit, which is a flat cast aluminum alloy housing with a lid and a transparent front wall.
Inside the body has four measuring mechanism of the magnetoelectric system vnutriramochnm magnet and the movable part in stretching, elements of the optical system and measuring system.
On the scale of the device M1742-M1 ammeter, voltmeter M1742-M1, M1742-M1 milliammeter designation applied measurand digitizing scale divisions on the horizontal and vertical channel numbers.
The minimum probability of failure of the device for 2,000 hours of testing not less than 0.9.
 

Photos M1742-M1

M1742-M1 front view (scale).
M1742-M1 front view (scale).
M1742-M1 side view (casing depth).
M1742-M1 side view (casing depth).
M1742-M1 rear view (connection).
M1742-M1 rear view (connection).
M1742-M1 overhead view.
M1742-M1 overhead view.