Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> narrow-profile DC

M1830

20 656 RUB
6 885 UAH
available:
65 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
M1830 ammeter, voltmeter M1830, M1830 microammeter, milliammeter M1830, M1830 millivoltmeter (M 1830, M-1830)
 
M1830 ammeter, voltmeter M1830, M1830 microammeter, milliammeter M1830, M1830 millivoltmeter are used to measure DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
Dimensions - 240h30h295mm.
Accuracy class - 0.5.
Narrow.
 
Technical characteristics of the devices M1830 ammeters, voltmeters, M1830, M1830 microammeter, milliammeter M1830, M1830 millivoltmeters:
 
They are used for measuring DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
The devices can be used to work in a set of transducers (sensors) SHGs.
Instruments M1830 ammeter, voltmeter M1830, M1830 microammeter, milliammeter M1830, M1830 millivoltmeter designed for flush mounting on panels and boards fixed installations.
The instruments are the five modifications:
- Pointing - A;
- Signaling - C;
- Three-pin - K;
- Pin DIP with the right contact - KP;
- Pin DIP with the left contact - CR.
Instruments M1830 ammeter, voltmeter M1830, M1830 microammeter, milliammeter M1830, M1830 millivoltmeter used to work at ambient temperatures from -30 º C to +50 ° C and relative humidity up to 90% (at 30 ° C).
Execution of regular and tropical.
Instruments issued in a tropical version, designed for operation at ambient temperature from -10 º C to +35 ° C and relative humidity of 95%.
With the direct inclusion of the unit M1830 ammeter, voltmeter M1830, M1830 microammeter, milliammeter M1830, M1830 millivoltmeter circuit in time and calm the 3s limits of measurement are as follows: 50mkA-0mkA-50mkA, 0mkA-100mkA; 100mkA-0mkA-100mkA; 0mkA-150mkA; 150mkA -0mkA-150mkA; 0mkA-300mkA, 300mkA-0mkA 300mkA-and-0mkA 500mkA;
- At time 1.5 seconds outside the calming measure - 500mkA-0mkA-500mkA, 0 mA-1 mA, 1 mA, 0 mA-1 mA, 0 mA-5 mA, 0 mA-5 mA-5 mA, 0 mA-10 mA, 0 mA-10 mA-10 mA, 0 mA to 20 mA , 0 mA-20 mA to 20 mA, 0 mA-30 mA, 0 mA-30 mA-30 mA, 0 mA-50 mA, 0 mA-50 mA-50 mA, 0 mA-100mA, 100mA 100mA, 0 mA-, 0 mA-150mA, 150mA 150mA, 0 mA-, 0 mA-300mA , 0 mA-300 mA-300 mA, 0 mA-500mA, 500mA 500mA, 0 mA-, 0A-1A, 1A-0A-1A 0A-2A, 2A-0A-2A, 5A and 0A-0A-5A-5A.
When the device is turned M1830 ammeter, voltmeter M1830, M1830 microammeter, milliammeter M1830, M1830 millivoltmeter with an external shunt 75mV and 45mV at the time and calm the 1.5 sec measurement limits are as follows: 0A-10A, 10A-0A-10A, 0A-20A, 20A -0A-20A, 0A-30A, 30A-0A-30A, 0A-50A, 50A-0A-50A, 0A-100A, 100A-100A-0s, 0s-150A, 150A-150A-0s, 0s-200A, 200A -0A-200A,-300A 0A, 0A-300A-300A, 500A-0s, 0s-500A-500A, 750A-0s, 750A-750A-0s; 0kA-1kA; 1kA-0kA-1kA; 0kA-2kA, 2kA -0kA-2kA, 0kA-3kA; 3kA-0kA-3kA; 0kA-4kA; 4kA-0kA-4kA; 0kA-5kA; 5kA-0kA-5kA; 0kA 6kA-and-6kA 0kA-6kA.
At rated current 0.2 mA and 4 seconds of time calming devices measuring range ammeter M1830, M1830 voltmeter, microammeter M1830, M1830 milliammeter, M1830 millivoltmeter - 0mV-10mV, 10mV, 10mV 0mV-; 0mV-20mV, 20mV, 20mV 0mV-; 0mV -45mV, 45mV, 45mV 0mV-; 0mV-50mV, 50mV, 50mV 0mV-; 0mV-100mV, 100mV, 100mV 0mV-; 0mV-200mV, 200mV, 200mV 0mV-; 0mV-500mV, 500mV, 500mV 0mV-; 0V -1V, 1V-0V-1V, 0V-1, 5V, 1.5V-0V-1, 5V, 0V-3V, 3V-0V-3V, 0V-7, 5 V, 7.5 V-0 V-7, 5B .
At rated current 1.0 mA and 1.5 seconds of time calming devices measuring range ammeter M1830, M1830 voltmeter, microammeter M1830, M1830 milliammeter, M1830 millivoltmeter - 0mV-75mV, 75mV, 75mV 0mV-, 0V to 10V, 10V-0V-10V , 0V-15V, 15V-0V-15V, 0V-30V, 30V-0V-30V, 0V-50V, 50V-0V-50V, 0V-75V, 75V-0V-75V, 0V-150V, 150V-150V-0V , 0V-250V, 250V-0V-250V, 0V-400V, 400V-0V-400V, 0V-600V, 600V, 600V-0V-.
Rated current millivoltmeter and voltmeter is different from the values ​​given above, no more than ± 20%.
The voltage drop across the microammeter, milliammeter and the ammeter does not exceed 120mV.
The main error types of devices M1830A, M1830S, M1830K, M1830KP and M1830KL is ± 0,5%; error trigger pin device types of devices and M1830A M1830S is absent, and devices M1830K, M1830KP and M1830KL - is ± 1,0%.
The length scale devices M1830 ammeter, voltmeter M1830, M1830 microammeter, milliammeter M1830, M1830 millivoltmeter - 200mm.
Operating position horizontal devices.
Change the ammeter readings M1830, M1830 voltmeter, microammeter M1830, M1830 milliammeter, M1830 millivoltmeter caused by ambient temperature deviation from normal is less than ± 0,4% for every 10 degrees, under the influence of external magnetic field strength of 400 A / m - not more than ± 0,5%.
Weight - no more than 1.8 kg.
Instruments M1830 ammeter, voltmeter M1830, M1830 microammeter, milliammeter M1830, M1830 millivoltmeter have a flat cast aluminum alloy, closed the lid.
Inside the case are available magnetoelectric measuring mechanism with vnutriramochnym magnet, with a moving part fixed to the inner braces, the optical system and elements of the measuring circuit.
 

Photos M1830

M1830 front view (scale).
M1830 front view (scale).
M1830 side view (casing depth).
M1830 side view (casing depth).
M1830 rear view (connection).
M1830 rear view (connection).