Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> narrow-profile DC

M1738MKP

35 069 RUB
14 028 UAH
available:
50 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
M1738MKP ammeter, voltmeter M1738MKP, microammeter M1738MKP, milliammeter M1738MKP, kiloampermetr M1738MKP (M 1738 MKP, M-1738-MKP, M1738 MKP, M1738-MKP, M 1738MKP, M-1738MKP)
 
M1738MKP ammeter, voltmeter M1738MKP, microammeter M1738MKP, milliammeter M1738MKP, kiloampermetr M1738MKP designed to measure DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
Dimensions - 160h30h272, 5mm.
Accuracy class - 1.0.
Vibration resistant, shockproof and vibration, with a signal to the filters and photoresistors.
 
Technical characteristics of the devices M1738MKP ammeters, voltmeters M1738MKP, microammeter M1738MKP, milliammeter M1738MKP, kiloampermetry M1738MKP:
 
Narrow-profile instruments magneto system with a light indicator designed to measure current and voltage in DC networks, and other electrical, magnetic and non-electrical parameters (if these units are normalized to the value of their testimony in terms of current or voltage), as well as for signaling on the measured value of of given values.
Devices M1738MKP ammeter, voltmeter M1738MKP, microammeter M1738MKP, milliammeter M1738MKP, kiloampermetr M1738MKP can work complete with regulating device, whose input is consistent with the parameters of photoconductive.
Ammeters and voltmeters are designed to operate at ambient temperatures from -30 º C to +50 ° C and relative humidity up to 100% at 50 ° C.
Devices M1738MKP ammeter, voltmeter M1738MKP, microammeter M1738MKP, milliammeter M1738MKP, kiloampermetr M1738MKP produced in tropical version will have the designation ... M1738MKPT2
Modifications of equipment and features of their design:
"Oh, is that all?" he said at last.
- C - Instrument with signal to the filters.
- K - signal to the device with color filters and a photoresistor (three-pin).Signals output from the measured value of the given values ​​to the right and left (on a scale of the instrument).
- KP - Device to signal to the filters and the photoresistor (pin DIP).Signals output from the measured value of the given values ​​to the right (on a scale of the instrument).
- CR - Indicates the output of the measured value of the given values ​​of the left (on a scale of the instrument).
External executive and signaling devices that connect the customer to contact the device devices M1738MKP ammeter, voltmeter M1738MKP, microammeter M1738MKP, milliammeter M1738MKP, kiloampermetr M1738MKP modifications to, CP, CR, should be protected from false positives by rapid changes in the measured value, for example, delay in operation of not less than 1s.
Measurement ranges of voltmeters: 0V-1V, 0V-5V, 0V to 10V, 0V-15V, 0V-30V, 0V-50V, 0V-75V, 0V-100V, 0V-150V, 0V-250V, 0V-400V, 0V- 600V.
Measurement ranges milliammeter: 0mkA-200mkA, 0 mA-5 mA and ammeters: 0A-1A 0A-2A; 0A-5A - a direct connection; 0A-10A, 0A-20A, 0A-30A, 0A-50A, 0A-75A, 0A -100A, 150A-0s, 0s-200A,-300A 0A, 0A, 500A, 750A-0s, 0s-1000A, 1500A-0A, 0A-2000A, 3000A-0A, 0A-4000A, 5000A-0A, 0A-6000A - Connection with external shunt 75mV.
Devices M1738MKP ammeter, voltmeter M1738MKP, microammeter M1738MKP, milliammeter M1738MKP, kiloampermetr M1738MKP available and with symmetrical double-sided scales.
Acceptable basic error limit is 1.0%.
Changing the readings ammeter M1738MKP, voltmeter M1738MKP, microammeter M1738MKP, milliammeter M1738MKP, kiloampermetr M1738MKP, caused by: changes in ambient temperature of 20 º C +5 º C to any temperature from -30 º C to +50 ° C with humidity up to 80% less than in every 10 ° C temperature change:
- For the voltmeter and milliammeter - 0.5%;
- For ammeters - ± 0,8%;
- The influence of external magnetic fields of 0.5 mT induction, does not exceed ± 1,0%;
- Changing the position of the instrument M1738MKP ammeter, voltmeter M1738MKP, microammeter M1738MKP, milliammeter M1738MKP, kiloampermetr M1738MKP at 45 ° from its normal position in any direction shall not exceed 1.0%.
The basic error and change of the readings is expressed as a percentage of full scale measurement range, and for devices with two-scale - from the sum of absolute values ​​of the finite range.
Response time devices M1738MKP ammeter, voltmeter M1738MKP, microammeter M1738MKP, milliammeter M1738MKP, kiloampermetr M1738MKP not exceed 3 seconds.
Dielectric strength 2kV.
Insulation resistance at 20 º C +5 ° C and relative humidity up to 80% - not less than 50 megohms.
Maximum permissible error in contact device actuation devices M1738MKP ammeter, voltmeter M1738MKP, microammeter M1738MKP, milliammeter M1738MKP, kiloampermetr M1738MKP to modify, CC and CL is equal to ± 2% of full scale range.
Output current contact device situated in the devices of modifications to, and CP CR 50mkA (no more) in a dark state and 250mkA (at least) - in an illuminated state when powered from a voltage source of 12V.
The light source used incandescent 0P6-3-B5 (6.7 V, 3.5 W) with the focusing cap.
Nutrition is the illuminator from the transformer P1710 (10 bulbs), P1711 (20 bulbs), P1712 (50 lamps) or from any DC or AC voltage of 6V.
This voltage should be between 10% -15% of nominal.
Overall dimensions M1738MKP ammeter, voltmeter M1738MKP, microammeter M1738MKP, milliammeter M1738MKP, kiloampermetr M1738MKP - 160x30x272, 5mm.
Weight - no more than 1.5 kg.
 