Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> alternating current low-frequency (less 1000Hz) >> size 96x96mm


999 RUB
250 UAH
60 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
    Milliammeter EA0703.10, ammeter EA0703.10, kiloampermetry EA0703.10
    Also, this device can be called: EA-0703.10, 0703.10 EA, ЄA0703.10, ЄA-0703.10, ЄA 0703.10, ea0703.10, ea-0703.10, ea 0703.10, EA-070 310, EA-0703-10, EA-0703 10.

    The meter and ammeter, kiloampermetry EA0703.10 - the device of an electromagnetic system to measure the current in the electrical circuits of single-phase alternating current.

    Specifications EA0703.10

    Dimensions 96x96x56 mm.
    Scale length - 95 mm.
    Accuracy class 1.5.

    Measuring ranges of devices and ways to include in the table.
Measurement range, A
100mA, 250mA, 400mA, 600mA
1A, 1.5A, 2A, 2.5A, 3A, 4A, 5A, 6A, 10A, 15A, 20A, 30A, 50A, 100A
5A, 10A, 15A, 20A, 30A, 40A, 50A, 75A, 100A, 150A, 200A, 300A, 400A, 500A, 600A, 800A
current transformer with a secondary current of 1A or 5A
1kA, 1.5 kA 2ka; 3kA; 4ka; 5kA, 6 kA, 10kA, 20kA, 30 kA, 40kA

    Operating conditions of devices EA0703.10

    Temperature from -40 ° C to +50 ° C.
    Relative humidity 95% at +35 ° C.
    Vibration resistance: acceleration of 15 m / s 2, the frequency of 30Hz.
    Vibration resistance: maximum acceleration of 5 m / s 2, the frequency of 20Hz.
    Shock: acceleration of 70 m / s 2, the frequency of 10-50 beats per minute.
    Frequency range: 50, 60, 200, 400, 500, 800, 1000 Hz.
    Unit weight EA0703.10 - 0.35 kg.
    Mean time to failure of devices - 50,000 hours.
    Average life - 12 years.

Яндекс цитирования