RLC measuring E7-14 (E714, E7 14)

Designed to measure the parameters of immitance elektroradiokomponentov: resistors, capacitors, inductors.
Operating frequencies of the instrument 0.1, 1 and 10 kHz with an error installing no more than 0.01%
Two levels of the measuring signal, V: 2 + 0.4 (40 + 8) x 10 -3
The output impedance of the signal source, Ohm: 100 ± 20

RLC measuring E7-14 is designed for digital measurement immittance elektroradiokomponentov parameters: resistors, capacitors, inductors. The device RLC meter E7-14 measures the following parameters immitance:
- Parallel and series capacitance (CP, CS);
- Parallel and series inductance (Lp, LS);
- Parallel and series resistance (RP, RS);
- A parallel conductance (G);
- Loss factor (D);
- Quality factor (Q).
The device RLC measuring E7-14 can operate in a system organized in line communities. It is used for input and output control radiokomponeitov, research parameters of circuit elements, semiconductor structures, calibration of immittance measures. measurement of physical quantities using transmitters.
Four-pair inclusion of the objects in the measuring circuit provides high metrological characteristics of the instrument RLC measuring E7-14 digital. Mode of low-level signal can be used for measurement in non-linear objects. Capable of providing mixing of the voltage on the object to be measured from the internal (up to the number), and from the outside (up to 120) sources.
RLC measuring E7-14 digital allow averaging the results of successive measurements to increase the resolution. They may work as part of the AIS through the CPC.

Technical characteristics
 
Operating frequencies of the instrument 0.1, 1 and 10 kHz with an error installing no more than 0.01%
Two levels of measurement signal to the
2 .4 (40 8) × 10 -3
The output impedance of the signal source, Ohm
100 ± 20
The capacitance C for frequencies of 0.1, 1, 10kHz
Measurement limit
0.1
1
10
1
0,0001-1,6000 nF
0,01-160,00 pF
0,001-16,000 pF
2
0,001-16,000 nF
0.1-1600.0pF
0,01-160,00 pF
3
0,01-160,00 nF
0,001-16,000 nF
0,0001-1,6000 nF
4
0,0001-1,6000 uF
0,01-160,00 nF
0,001-16,000 nF
5
0,001-16,000 uF
0,1-1600,0 nF
0,01-160,00 nF
6
16,000-160,0 uF
1,6000-16,00 uF
160.00-1600nF
7
0,16000-1,600 mF
16,000-160,0 uF
1 uF .6000-16,00
8
1,600-16,00 mF
160.0-1600mkF
16,000-160,0 uF
Inductance L at frequencies of 0.1, 1, 10 kHz
Measurement limit
0.1
1
10
1
1,6000-16,00 KGN
160.00-1600Gn
Mr 16,000-160,0
2
160.00-1600Gn
Mr 16,000-160,0
Mr 1,6000-16,00
3
Mr 16,000-160,0
Mr 1,6000-16,00
160.00-1600mGn
4
Mr 1,6000-16,00
160.00-1600mGn
16,000-160,0 mH
5
160.00-1600mGn
16,000-160,0 mH
1,6000-16,00 mH
6
0,01-160,00 mH
0,001-16,000 mH
0.1 1600mGn
7
0,001-16,00 mH
0.1 1600mkGn
0,01-160,00 uH
8
0,1-1600,0 uH
0,01-160,00 uH
0,001-16,000 uH
Loss factor Q and measured in the range from 10-4 to 104 E7-14
Measurement limit
G
R
1
0,0001-1,000 mkSm
1,000-10,00 MW (up 1000MOm)
2
0,001-10,000 mkSm
100,00-1000 k
3
0,01-100,00 mkSm
10,00-100,0 k
4
0,1-1000,0 mkSm
1,0000-10,00 k
5
0,001-10,000 mS
100,00-1000 Ohm
6
10,000-100,0 mS
0,01-100,0 Ohm
7
100,00-1000 mS
0,001-10,000 ohms
8
1,0000-10,00 D
0,1-1000,0 milliohms
Limit of acceptable basic error of measurement
imittansnyh parameters at a high level signal and the normal speed measurement
Capacitance, C
Measurement limit
Frequency kHz
Measurement error
1
0.1
1, 10
10 -3 (1 + D) C 3 · 10 -4 S '
10 -3 (1 + D) from 2.5 × 10 -4 S '
2-5
0.1, 1, 10
10 -3 (1 + D) from 2 × 10 -4 S '
6.7
0.1, 1, 10
[10 -3 (1 + D) +2 · 10-3 S / S '] C
8
0.1
1, 10
[10 -3 (1 + D) +3 · 10-3 S / S '] C
[10 -3 (1 + D) +2,5 · 10-3 S / S '] C
The inductance, L
1
0.1
1, 10
[10 -3 (1 + D) +3 · 10 -3 L / L '] L
[10 -3 (1 + D) +2,5 · 10 -3 L / L '] L
2-5
0.1, 1, 10
[10 -3 (1 + D) +2 · 10 -3 L / L '] L
6-7
0.1, 1, 10
10 -3 (1 + D) L +2 · 10 -4 L '
8
0.1
1, 10
10 -3 (1 + D) L +3 · 10 -4 L '
10 -3 (1 + D) L +2,5 · 10 -4 L '
Resistance, R
1
0.1
1, 10
[10 -3 (1 + Q) +3 · 10 -3 R / R '] R
[10 -3 (1 + Q) +2,5 · 10 -3 R / R '] R
2-5
0.1, 1, 10
[10 -3 (1 + Q) +2 · 10 -3 R / R '] R
6-7
0.1, 1, 10
10 -3 (1 + Q) R +2 · 10 -4 R '
8
0.1
1, 10
10 -3 (1 + Q) R +3 · 10 -4 R '
10 -3 (1 + Q) R +2,5 · 10 -4 R '
Conductivity, G
1
0.1
1, 10
10 -3 (1 + Q) G+ 3.10 -4 G '
10 -3 (1 + Q) G+ 2,5 · 10 -4 G '
2-5
0.1, 1, 10
10 -3 (1 + Q) G+ 2.10 -4 G '
6-7
0.1, 1, 10
[10 -3 (1 + Q) +2 · 10 -3 G / G '] G
8
0.1
1, 10
[10 -3 (1 + Q) +3 · 10 -3 G / G '] G
[10 -3 (1 + Q) +2,5 · 10 -3 G / G '] G
The loss factor, D
1
0.1
1, 10
10 -3 (1 + D2) +3 · 10 -4 (1 + D) C / C '
10 -3 (1 + D2) +2,5 · 10 -4 (1 + D) C / C '
2-5
0.1, 1, 10
10 -3 (1 + D2) +2 · 10 -4 (1 + D) C / C '
6-7
0.1, 1, 10
10 -3 (1 + D2) +3 · 10 -3 (1 + D) C / C '
8
0.1
1, 10
10 -3 (1 + D2) +3 · 10 -3 (1 + D) C / C '
10 -3 (1 + D2) +2,5 · 10 -3 (1 + D) C / C '
The quality factor, Q
1
0.1
1, 10
10 -3 (1 + Q2) +3 · 10 -3 Q (1 + Q) L / L '
10 -3 (1 + Q2) +2,5 · 10 -3 Q (1 + Q) L / L '
2-5
0.1, 1, 10
10 -3 (1 + Q2) +2 · 10 -3 Q (1 + Q) L / L '
6-7
0.1, 1, 10
10 -3 (1 + Q2) +2 · 10 -4 Q (1 + Q) L / L '
8
0.1
1, 10
10 -3 (1 + Q2) +3 · 10 -4 Q (1 + Q) L / L '
10 -3 (1 + Q2) +2,5 · 10 -4 Q (1 + Q) L / L '
With `, L`, R `, G`, D `, Q` - maximum values ​​of this limit measure
Power supply E7-14
220V AC power, 50Gts/400Gts.
Warm-up time, min
15
Power consumed by the device, VA
Not more than 40
Operating conditions:
 
- Temperature, ° C
5 to 40
- Moisture content,%
80
- Pressure, mm Hg. Art.
630 - 795
Overall dimensions, mm
254h314h184
Weight, kg
5