Electrical measuring instruments >> analog panel meters >> panel with round scale devices for harsh environments >> size 175х195mm

Electron-1

45 000 RUB   |   11 025 UAH   |  available: 7 pieces
ELEKTRON-1 device image.
Megger ELECTRON-1 (ELECTRON1, ELEKTRON 1)
Designed for continuous automated monitoring of insulation resistance of ship electric networks single-phase and three-phase AC voltage up to 400V, 50Hz-500Hz with ungrounded as the presence of voltage in a controlled network, and in his absence;
The device provides continuous automatic control of the insulation, allows visual observation of the numerical value of the insulation resistance from 0 m to 1 MW automatically includes audible and visual alarm when insulation resistance is below the specified set point;
Insulation resistance of electrical circuits to housing should not be less than:
- 20 M - under normal weather conditions - temperature +25 º C ± 10 ° C, relative humidity of 65% ± 15%, ± 100 kPa pressure 4kPa;
- 5 MOhm - at a temperature of +50 ° C ± 2 º C, humidity of 65% ± 3%;
- 1 M - at +25 º C ± 2 ° C, humidity of 95% ± 3%.

More info ...

ELEKTRON-1R

45 000 RUB   |   11 025 UAH   |  available: 7 pieces
ELEKTRON-1R device image.
Megaohmmeter ELEKTRON-1R (ELEKTRON1R, ELEKTRON 1R)
Designed for continuous automated monitoring of insulation resistance of ship electric networks single-phase and three-phase AC voltage up to 400V, 50Hz-500Hz with ungrounded as the presence of voltage in a controlled network, and in his absence;
The device provides continuous automatic control of the insulation, allows visual observation of the numerical value of the insulation resistance from 0 m to 1 MW automatically includes audible and visual alarm when insulation resistance is below the specified set point;
Insulation resistance of electrical circuits to housing should not be less than:
- 20 M - under normal weather conditions - temperature +25 º C ± 10 ° C, relative humidity of 65% ± 15%, ± 100 kPa pressure 4kPa;
- At least 1 MOhm - at +40 ° C ± 2 º C, humidity of 95% ± 3%.

More info ...

ELEKTRON-T

45 000 RUB   |   11 025 UAH   |  available: 7 pieces
ELEKTRON-T megger image.
Megaohmmeter ELEKTRON-T (ELETRONT, ELEKTRON T)
Designed for continuous automated monitoring of insulation resistance of ship electric networks single-phase and three-phase AC voltage up to 400V, 50Hz-500Hz with ungrounded as the presence of voltage in a controlled network, and in his absence;
The device provides continuous automatic control of the insulation, allows visual observation of the numerical value of the insulation resistance from 0 m to 1 MW automatically includes audible and visual alarm when insulation resistance is below the specified set point;
Insulation resistance of electrical circuits to housing should not be less than:
- 20 M - under normal weather conditions - temperature +25 º C ± 10 ° C, relative humidity of 65% ± 15%, ± 100 kPa pressure 4kPa;
- At least 1 MOhm - at +40 ° C ± 2 º C, humidity of 95% ± 3%.

More info ...