Electrical measuring instruments >> transformers industrial >> voltage transformers >> single-phase voltage transformer

ZNOLPM-10

17 244 RUB
5 340 UAH

Online prices include VAT.

For order is possible effectively delivery of any quantity.
    Earthing transformer voltage ZNOLPM-10 (ZNOLPM10, ZNOLPM 10, ZNOLPM 10 UHL2)
    Earthing transformer voltage ZNOLPM-10 is designed for use in electrical circuits AC 50Hz signal to transfer measurement data measurement devices, protection, automation, alarm and control.
    Transformers are made for the needs of the power industry, including nuclear power plants (NPP), and are designed for installation in complete switchgear, as well as for installation in wireways turbogenerators.
    Avoid prolonged operation of transformers, as power, that is, outside the guaranteed accuracy class, with a load does not exceed the capacity.
    Specifications This product is grounded voltage transformers ZNOLPM-10:
    Voltage Class - 10kV;
    Maximum operating voltage of the device grounding transformer voltage ZNOLPM-10 - 12kV;
    Rated voltage of the primary winding - (10 000 / ) V, (10500 / ) V, (11000 / ) V;
    Rated voltage of the main secondary product is grounded voltage transformer ZNOLPM-10 - (100 / ) V;
    Rated voltage additional secondary winding - 100/3V or 100V;
    Accuracy classes of primary secondary - 0.2, 0.5, 1;
    Rated power of main secondary winding device grounding transformer voltage ZNOLPM 10 UHL2 power factor active-inductive load 0.8:
    - In accuracy class 0.2 - 10V · A;
    - In accuracy class 0.5 - 30V · A;
    - In class 1 - 90V · A;
    Rated power of additional secondary winding device grounding transformer voltage ZNOLPM-10 power factor active-inductive load 0.8 in accuracy class 3 - 200 V · A;
    Maximum power is outside the class of accuracy - 400 · A;
    Maximum permissible continuous primary current - 0.07 A, 0.06 A;
    Scheme and winding connection group product is grounded voltage transformer ZNOLPM-10 - 1/1/1-0-0;
    Rated short-circuit voltage under load for accuracy class 0.5 - 0.41%;
    The response time of protective safety devices - according to figure 1;
    Resistor type in the internal safety device safety device grounding transformer voltage ZNOLPM UHL2-10 - C2-33-H-0, 25;
    The nominal power of the resistor - 0.25 W;
    This product is grounded resistor voltage transformer ZNOLPM 10 - 11 ohms;
    Rated frequency - 50 Hz;
    Figure 1: Time  safety relief device product is grounded voltage transformer ZNOLPM-10

Time  safety relief device product is grounded voltage transformer ZNOLPM-10
 
    General view of the device shown in Figure 2;
    Figure 2: General view of the product is grounded voltage transformer ZNOLPM-10

General view of the product is grounded voltage transformer ZNOLPM-10
 
    Weight of the device grounding transformer voltage ZNOLPM-10 - 22kg ± 0,5 kg;
    The transformers are manufactured in climatic design "Y" and are intended for indoor use in:
    - Height above sea level is not more than 1000m;
    - Ambient temperature with the heat the air inside the switchgear - from -60 ° C to +55 ° C;
    - Relative humidity - 100% at 25 º C;
    - Environment-explosive, without dust, corrosive gases and vapors in concentrations destroying coating metals and insulation;
    - Working position - any;
    - Internal insulation product is grounded voltage transformer ZNOLPM 10 UHL2 cast, heat resistance class "B" and flammability class FH (PG) 1;
    - Instruments earthquake resistant when exposed to earthquake intensity of 9 points on the MSK-64 at the facility level above ground level up to 70m;
    - Appliances intended to be sold in AS, with class security for 3H-001 NP-97 and 2 seismic category for NP-031-01
    - Equipment grounding transformer voltage ZNOLPM-10 meet the requirements of resistance to electromagnetic interference when exposed to a magnetic field of industrial frequency;
    - Devices conform to standards of industrial radio Class A, Group 1;
    The manufacturer guarantees that the quality of product is grounded voltage transformer ZNOLPM-10 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.

Photos ZNOLPM-10

Earthing transformer voltage ZNOLPM-10.
Earthing transformer voltage ZNOLPM-10.


Яндекс цитирования