Electrical measuring instruments >> breakdown devices

UPU-6 Universal setting the breakdown UPU-6.

UPU-6

54 000 RUB
15 120 UAH

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Universal setting the breakdown UPU-6 (UPU6, UPU 6)
 
Universal setting the breakdown UPU-6 is designed to test the insulation of electrical equipment and supplies AC sinusoidal voltage frequency 50 Hz and rectified voltage of negative polarity, adjustable to 0kV 6 kV with an output current of up to 100mA.
The plant can be used in research institutes, testing laboratories, repair shops, on the bases for technological development in enterprises for testing and repair of electronic equipment.
Due to increased output current device universal setting the breakdown UPU-6 can be used to test for AC voltage windings of large electrical machines.
Can be successfully used for testing of protective equipment to the appropriate voltage (gloves, etc.), as well as to charge the energy storage capacitor.
 
Technical characteristics of the devices installed universal breakdown UPU-6:
 
The unit is designed for indoor or under cover at the operating temperatures of air from +5 ° C to +40 ° C, relative humidity 80% at +20 ° C and atmospheric pressure of 84.0 kPa, 106, 7kPa (630mm.rt . Art.-800mm.rt.st.);
Power supply is a universal setting the breakdown UPU-6 - single phase sinusoidal AC 220V ± 20V, 50Hz ± 1Hz;
Installation operated by one operator with the right to work on systems with voltages above 1000V;
Limits set the output voltage setting device universal the breakdown UPU-6 - 1 kV, 3 kV, 6 kV;
Reduced relative error of measurement and output voltage - no more than 3%;
Maximum output current device universal setting the breakdown UPU-6 - 100 mA;
Reduced error of measuring the current - not more than 3%;
Threshold current protection device universal setting the breakdown UPU-6 - 105mA ± 5mA;
Power consumption - no more than 650V · A;
Overall dimensions universal setting the breakdown UPU-6 - 480h200h350mm;
Weight - no more than 25 kg;
Time of continuous operation at maximum capacity - 8 hours;
Average life of the instrument setting the breakdown universal UPU-6 - 6 years;
Kilovoltmeter installation measures the ac voltage - RMS, the rectified - the amplitude of the voltage;
Milliammeter to measure the AC current value by the average rectified (srednevypryamlennoe) current;
The manufacturer guarantees that the quality of the instrument setting the breakdown universal UPU-6 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.