Electrical measuring instruments >> digital panel meters

TsL2135 Varmeter TSL2135.

TsL2135

17 037 RUB
4 260 UAH
available:
48 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Varmetr TsL2135 (TsL 2135, TsL-2135)
 
Varmetr TsL2135 designed to measure and record the power plants of electric power.
Dimensions - 160x80x140mm.
 
Technical characteristics of the devices varmetry TsL2135:
 
Industrial companies can arrange for monitoring and recording of power consumption, and using the block settings to prompt alarm on exceeding the value of the power, the power supply organization declared as a limit.
Single-phase devices varmetr TsL2135 allow you to:
- Measurement of active power in single-phase AC networks 50Hz;
- Exchange of information on the RS485 or RS232;
- A linear transformation of the measured power-Pnom. to + Pnom. output signal in a unified force from 0 mA DC to 5 mA, 0 mA to 20 mA of from 4 mA to 20 mA;
- Comparison of the measured value with the specified dimensions within the range of two settings (set point and set point in excess of the reduction). Setpoint device varmetr TsL2135 through software via RS485 or RS232 interface with a computer;
- Operation of the standard instrument transformers (CT) with an output current of 5 amps or standard voltage transformers (VTs) with an output voltage of 100V;
- The introduction of a scaling factor, which provides an indication of the measurement result in physical units, taking into account the transformation ratio of the external CT or VT;
Each of the devices varmetr TsL2135 combines the two measuring devices - the converter being measured in the current or the digital signal and the measuring device with digital display.
 
Rated power factor: cos φ = 1, sin φ = 1.
Assignment scheme include devices varmetr TsL2135 (four-or three-wire) through software in the service mode via the RS-232 or RS-485.
 
Nominal value
Interphase voltage Un., B
Phase voltage Uf nom., B
The current phase Іnom., A
Power three-phase system Qrated., Var
100V
100 / √ 3V
5A
866.0 Var
1A
173.2 Var
380
380 / √ 3V
5A
3291var
1A
658.2 Var
Note - When measuring the power of three-phase system with the use of external current and voltage transformers used appliance with an input voltage Un. Equal to 100V. The values ​​of the primary current and voltage transformers and external value of the secondary current Іnom. (1A or 5A) are given by the customer when ordering.
 
Measurement error of the instrument varmetr TsL2135
± 0,5%
Measurement error with non-uniform load phase
not more than 0.5%.
Acceptable forms of distortion curve of the measured signal
sine wave distortion factor of the measured voltage and current of up to 30% under the influence of harmonics from second to 13th.
Permitted overload on the input channel
- A voltage greater than 2 times the nominal value within 2 h;
- Two overload currents exceeding 7 times the rated value, the duration of 15s, with an interval of 60 seconds;
- Two overload currents exceeding 10 times the rated value, the duration of 5 s at intervals of 10 s;
- Five overload currents exceeding 20 times the rated value, the duration of 1 s, with an interval of 300C.
The display device varmetr TsL2135 information
- The value of the measured power in the form of
4-digit decimal number and a comma;
- Dimension "Tues", "kw", "MW";
- "-" Sign for the power output
- Signs of settings ">", "=" and "<";
- The message «OL» in excess of the measured power value 1.6 Hnom
Setting the number of comparisons
2
The number of switched circuits
2
The parameters of switched circuits:
- Maximum voltage AC or DC
- The maximum switching current

250
no more than 100mA
Supply voltage
~ Ot100V to 220V 50Hz or 100V = from do300V
Consumed by the device varmetr TsL2135 power
- From the food chain
- From the circuit input signal to each successive chain
- From the input circuit for each branch circuit
Un up to 100V
for up to 380 Un
 

no more than 10 V ∙ A
no more than 2C ∙ A
 
 
0.2 A ∙
0.6 A ∙
Overall dimensions
not more than 160 × 80 × 140mm
Digit height indicator device
25mm
Unit weight varmetr TsL2135
not exceeding 1 kg
Operating conditions of use:
- Ambient air temperature
- Relative humidity

from +5 º C to +50 ° C;
90% at 25 ° C.
 
Symbol device varmetr TsL2135:
TsL2135-XX-Y-ZW, where
XX: characterization of the input signal, where the first digit specifies the nominal voltage:
- 1 - 100V;
- 2 - 220;
- 3 - 380;
the second number specifies the rated current:
- 1 - 5A;
- 2 - 1A.
11 or 12 with the coefficients of transformation - the instrument for measuring varmetr TsL2135 with external current transformers and voltage, the specific value of the primary current and voltage transformers in the external order is in parentheses after the symbol.
- Y - glow color indicators;
- K - red;
- B - green;
- Z - Interface:
- 1 - RS-232;
- 2 - RS-485.
- W - presence in the instrument varmetr TsL2135 transducer measured value of power in a uniform signal strength for a range of DC conversion:
- 1 - with an output current of 0 mA to 5 mA;
- 2 - with an output current of 4 mA to 20 mA;
- 3 - with an output current of 0 mA to 20 mA;
- 0 - there is no current output.
An example entry in order and in the technical documentation of other products:
- Single phase with the input varmetra TsL2135 nominal voltage of 220V and input current 1A, light color - red, exit to the RS-232 interface, the presence of the current output of 4 mA to 20 mA:
"Varmetr TsL2135-22 K-12 TU4221-033-71064713-2007".
- Single phase varmetra for measurements with an external current transformer with a value of primary current 2kA, the value of secondary current 5A and external voltage transformer with a value of primary voltage 250kV, the value of secondary voltage 100V, indicator light color - green, RS-485 interface, without the current output:
"Varmetr TsL2135-11-B-20 (2kA, 250kV) TU4221-033-71064713-2007".
 