Discount 50% on the panel round witted devices.

Electrical measuring instruments >> analog panel meters >> panel with round scale devices for harsh environments >> size 80х80mm

C1427 Wattmeter TS14728, varmeter TS1427.

C1427

37 442 RUB
9 173 UAH
available:
58 pieces

Online prices include VAT.

It is possible effectively delivery of any quantity.

Discount 50% on panel round-witted devices.

Full list of promotional items can be viewed here.


 

The device is produced in 2017.

All measurement ranges and settings are available.

It is possible to customize any special scales.

 

Wattmeter C1427, C1427 varmetr (C-1427, C 1427)
 
Wattmeter C1427, C1427 varmetr designed to measure active and reactive power in three-phase networks of marine power plants, 50 Hz and 400 Hz.
Vibration-resistant, shock-resistant.
 
Technical characteristics of the devices wattmeters C1427, C1427 varmetry:
- The ambient air temperature of -40 º C to +55 º C;
- Relative humidity up to 100% at 50 º C;
- Measuring range, rated currents and voltages, ways to connect the unit are stated in C1427 Table 1-3;
Rated active power factor cosφ - 1,0;
Nominal Power Factor sinφ - 1,0;
Nominal frequency - 50 Hz and 400 Hz (see Table 1-4), 50 Hz (Table 1-4);
 
Table 1 wattmeters with the zero mark on the edge of range
 
Rated current
Nominal Voltage
127V
220V
380V
Measurement range:
5A
0kVt-1kW
0kVt-2kW
0kVt-3kW
10A
0kVt-2kW
0kVt-4kW
0kVt-6kW
20A
0kVt-4kW
0kVt-8kW
0kVt-12kW
30A
0kVt-6kW
0kVt-12kW
0kVt-20kW
50A
0kVt-10kW
0kVt-20kW
0kVt-30kW
75A
0kVt-15kW
0kVt-30kW
0kVt-50kW
100A
0kVt-20kW
0kVt-40kW
0kVt-60kW
150 A
0kVt-30kW
0kVt-60kW
0kVt-100kW
200A
0kVt-40kW
0kVt-80kW
0kVt-120kW
300A
0kVt-60kW
0kVt-120kW
0kVt-200kW
400A
0kVt-80kW
0kVt-150kW
0kVt-250kW
600A
0kVt-120kW
0kVt-250kW
0kVt-400kW
750A
0kVt-150kW
0kVt-300kW
0kVt-500 kW
800A
0kVt-150kW
0kVt-300kW
0kVt-500 kW
1000 A
0kVt-200kW
0kVt-400kW
0kVt-600kVt
1500 A
0kVt-300kW
0kVt-600kVt
0kVt-1000kVt
2000A
0kVt-400kW
0kVt-800kVt
0kVt-1200kVt
3000A
0kVt-600kVt
0kVt-1200kVt
0kVt-2000kW
4000A
0kVt-800kVt
0kVt-1500 kW
0kVt-2500kVt
5000A
0kVt-1000kVt
0kVt-2000kW
0kVt-3000kVt
6000A
0kVt-1200kVt
0kVt-2500kVt
0kVt-4000kVt
8000A
0kVt-1500 kW
0kVt-3000kVt
0kVt-5000kVt
10000A
0kVt-2000kW
0kVt-4000kVt
0kVt-6000kVt
 
Table 2 wattmeters with the zero mark on the edge of range
 
Rated current
Nominal Voltage
127V
220V
380V
Measurement range:
5A
0.15 kW, 1 kW 0kVt
0.3 kW, 2 kW 0kVt
0.5 kW, 3 kW 0kVt
10A
0.3 kW, 2 kW 0kVt
0.6 kW, 4 kW, 0kVt
1kW-0kVt-6kW
20A
0.6 kW, 4 kW, 0kVt
0.2 kW-0kVt-8kW
2kW-12kW-0kVt
30A
1kW-0kVt-6kW
2kW-12kW-0kVt
3kW-20kW-0kVt
50A
1.5 kW, 10 kW-0kVt
3kW-20kW-0kVt
5kW, 30kW 0kVt-
75A
2.5 kW, 15 kW-0kVt
5kW, 30kW 0kVt-
8kW, 50kW, 0kVt
100A
3kW-20kW-0kVt
6kW-40kW-0kVt
10kW-60kW-0kVt
150 A
5kW, 30kW 0kVt-
10kW-60kW-0kVt
15kW-100kW-0kVt
200A
6kW-40kW-0kVt
12kW-80kW-0kVt
20kW-120kW-0kVt
300A
10kW-60kW-0kVt
20kW-120kW-0kVt
30kW-200kW-0kVt
400A
12kW-80kW-0kVt
25kW-150kW-0kVt
40kW-250kW-0kVt
600A
20kW-120kW-0kVt
40kW-250kW-0kVt
60kW-400kW-0kVt
750A
25kW-150kW-0kVt
50kW-300kW-0kVt
80kW-500 kW-0kVt
800A
25kW-150kW-0kVt
50kW-300kW-0kVt
80kW-500 kW-0kVt
1000 A
30kW-200kW-0kVt
60kW-400kW-0kVt
100kW-0kVt-600kVt
1500 A
50kW-300kW-0kVt
100kW-0kVt-600kVt
150kW-0kVt-1000kVt
2000A
60kW-400kW-0kVt
120kW-0kVt-800kVt
200kW-0kVt-1200kVt
3000A
100kW-0kVt-600kVt
200kW-0kVt-1200kVt
300kW-2000kW-0kVt
4000A
120kW-0kVt-800kVt
250kW-1500 kW-0kVt
400kW-0kVt-2500kVt
5000A
150kW-0kVt-1000kVt
300kW-2000kW-0kVt
500 kW-0kVt-3000kVt
6000A
200kW-0kVt-1200kVt
400kW-0kVt-2500kVt
600kVt-0kVt-4000kVt
8000A
250kW-1500 kW-0kVt
500 kW-0kVt-3000kVt
800kVt-0kVt-5000kVt
10000A
300kW-2000kW-0kVt
600kVt-0kVt-4000kVt
1000kVt-0kVt-6000kVt
 
Table 3 Ranges varmetrov
 
Rated current
Nominal Voltage
127V
220V
380V
Measurement range:
5A
0.5-quark 0kvar 1kvar
1kvar-0kvar-2kvar
1.5-quark 0kvar 3kvar
10A
1kvar-0kvar-2kvar
2kvar-0kvar-4kvar
3kvar-0kvar-6kvar
20A
2kvar-0kvar-4kvar
4kvar-0kvar-8kvar
6kvar-0kvar-12kvar
30A
3kvar-0kvar-6kvar
6kvar-0kvar-12kvar
10kvar-0kvar-20kvar
50A
5kvar-0kvar-10kvar
10kvar-0kvar-20kvar
15kvar-0kvar-30kvar
75A
8kvar-0kvar-15kvar
15kvar-0kvar-30kvar
25kvar-0kvar-50kvar
100A
10kvar-0kvar-20kvar
20kvar-0kvar-40kvar
30kvar-0kvar-60kvar
150 A
15kvar-0kvar-30kvar
30kvar-0kvar-60kvar
50kvar-0kvar-100kvar
200A
20kvar-0kvar-40kvar
40kvar-0kvar-80kvar
60kvar-0kvar-120kvar
300A
30kvar-0kvar-60kvar
60kvar-0kvar-120kvar
100kvar-0kvar-200kvar
400A
40kvar-0kvar-80kvar
80kvar-0kvar-150kvar
120kvar-0kvar-250kvar
600A
60kvar-0kvar-120kvar
120kvar-0kvar-250kvar
200kvar-0kvar-400kvar
750A
80kvar-0kvar-150kvar
150var-0kvar-300kvar
250kvar-0kvar-500kvar
800A
80kvar-0kvar-150kvar
150kvar-0kvar-300kvar
250kvar-0kvar-500kvar
1000 A
100kvar-0kvar-200kvar
200kvar-0kvar-400kvar
300kvar-0kvar-600kvar
1500 A
150kvar-0kvar-300kvar
300kvar-0kvar-600kvar
500kvar-0kvar-1000kvar
2000A
200kvar-0kvar-400kvar
400kvar-0kvar-800kvar
600kvar-0kvar-1200kvar
3000A
300kvar-0kvar-600kvar
600kvar-0kvar-1200kvar
1000kvar-0kvar-2000kvar
4000A
400kvar-0kvar-800kvar
800kvar-0kvar-1500kvar
1200kvar-0kvar-2500kvar
5000A
500kvar-0kvar-1000kvar
1000kvar-0kvar-2000kvar
1500kvar-0kvar-3000kvar
6000A
600kvar-0kvar-1200kvar
1200kvar-0kvar-2500kvar
2000kvar-0kvar-4000kvar
8000A
800kvar-0kvar-1500kvar
1500kvar-0kvar-3000kvar
2500kvar-0kvar-5000kvar
10000A
1000kvar-0kvar-2000kvar
2000kvar-0kvar-4000kvar
3000kvar-0kvar-6000kvar
 
Table 4 Ranges wattmeters for the rated voltage 690V and 6300V
 
Nominal Voltage
Rated current
Measuring range
Connecting the parallel chains
Connecting a serial chain
690
3000A
0.5 MW-3 MW-0MVt
Transformer voltage 690/127 or 660/127
Through the current transformer secondary winding on the transformer 5A and 5/1
6300V
300A
0.5 MW-3 MW-0MVt
After a voltage transformer 6300/127 or 6300/100
500A
0.8 MW-0, 5MW
 
- Power consumption of each series circuit and wattmeter varmetrov at rated current and rated frequency not exceeding 5 V ∙ A;
- Power consumption for each parallel circuit and wattmeter varmetrov at rated current and rated frequency not exceeding 5 V ∙ A;
- Acceptable basic error limit is ± 2,5% of the length of the scale;
- Maximum permissible additional error C1427 caused by:
- Changes in ambient temperature from the normal 20 º C ± 5 º C to any temperature between -40 º C to +55 º C for every 10 º C temperature change is equal to ± 1,25%;
- Changes in supply voltage of ± 20% of the nominal is ± 2,5%;
- Change in working position (tilt) of the device C1427 from normal in any
direction by 45 º, is ± 1%;
- The basic and additional errors are normalized without errors measuring current and voltage transformers, and are expressed as a percentage of full scale measurement range, and for wattmeters and varmetrov with two-scale - from the sum of absolute values ​​of end of range;
- Test voltage isolation between the measuring circuit and housing showing the device and the power meter and an electric circuit varmetra additional device and its body - 1.5 kV;
- Insulation resistance of electrical circuits, showing the device relative to the housing and an additional device and the housing - 20 MW;
- Response time showing the device does not exceed 3 seconds;
- The length scale of the instrument C1427 110mm ± 5mm;
- Overall dimensions of the device showing - 80h80h126mm;
- Dimensions of additional equipment R1818, R1818 / 1 - 160h170h144mm;
- Weight of the device showing - not exceeding 1 kg;
- Weight of additional devices R1818, R1818 / 1 - no more than 3kg.