Electrical measuring instruments >> transformers industrial >> current transformers >> 10kV voltage class

TL-10M-2-I-1

For order is possible effectively delivery of any quantity.
Current transformer TL-10M-2-I-1 (TL10M2I1, TL 10M 2 I 1, TL10M-2-I-1, TL10M 2 I 1, TL-10M2I1, TL 10M2I1, TL-10M-2-1-1, TL-10M-II-II)
 
Current transformer TL-10M-2-I-1 is designed for installation in complete switchgear (KRU) and serves to signal measurement information instrumentation and (or) protection and control, to isolate the circuits of secondary compounds of high-voltage electrical installations AC voltage class up to 10kV 50Hz or 60Hz.
Technical characteristics of the instrument current transformer TL-10M-2-I-1:
 
The number of secondary windings - 2;
Rated voltage - 10kV or 11kV;
Maximum operating voltage of the device current transformer TL-10M-2-I-1 - 12kV;
Rated frequency AC - 50Hz or 60Hz;
Rated secondary current of the current transformer unit TL-10M-2-I-1 - 5A;
Rated primary current - 5A, 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A, 200A;
Accuracy class of the instrument current transformer TL-10M-2-I-1:
- Secondary winding for measurement - 0,5; 0,5 S, 0,2; 0,2 S;
- Secondary protection - 5P, 10P *;
Rated secondary current transformer load device TL-10M-2-I-1, with a power factor:
- Cos φ = 1 - secondary winding for measurement - 1 V · A-2, 5 V · A;
- Cos φ = 0,8 - secondary winding for measurement - 3V-50V · A · A;
- Cos φ = 0,8 - secondary protection - 3V-30V · A · A;
Rated current ratio of secondary winding for protection - 2-30;
Nominal factor of safety devices for the secondary current transformer measuring device TL-10M-2-I-1 - 2-30;
Contact diameter primary - 24mm;
A one-second thermal current instrument current transformer TL-10M-2-I-1:
- At rated primary current 5A - 0.4 kA
- At rated primary current 10A - 0.78 kA
- At rated primary current 15A - 1.2 kA
- At rated primary current 20A-1.56 kA
- At rated primary current 30A - 2.5 kA
- At rated primary current 40A - 3kA;
- At rated primary current 50A - 5kA;
- At rated primary current 75A - 5.85 kA
- At rated primary current 80A - 6.23 kA
- At rated primary current 100 A - 10 kA;
- At rated primary current 150A - 12.5 kA
- At rated primary current 200A - 20kA;
Rated peak withstand current transformer unit TL-10M-2-I-1:
- At rated primary current 5A - 1kA;
- At rated primary current 10A - 1.97 kA
- At rated primary current 15A - 3kA;
- At rated primary current 20A-3.93 kA
- At rated primary current 30A - 6.25 kA
- At rated primary current 40A - 7.56 kA
- At rated primary current 50A - 12.8 kA
- At rated primary current 75A - 14.7 kA
- At rated primary current 80A - 15.7 kA
- At rated primary current 100A - 25.5 kA
- At rated primary current 150A - 31.8 kA
- At rated primary current 200A - 51kA;
The estimated value of the resistance of the secondary winding current transformer unit TL-10M-2-I-1 DC are listed in Table 1;
 
Table 1 Calculated values ​​of the resistance of the secondary windings of the current transformer unit TL-10M-2-I-1 DC
 
Rated current of the device current transformer TL-10M-2-I-1
Accuracy class
DC resistance of the windings
5A-75A, 100A-300A
0,2 S, 0,2, 0,5 S
0,5
5P, 10P
-
-
-
5A-200A
0,2 S, 0,2, 0,5 S
0,5
5P, 10P
-
-
-
40A, 80A, 200A
0,2 S, 0,2, 0,5 S
0,5
5P, 10P
0.1 kOhm
0.13 Ohm
0.17 Ohm
5A, 30A, 50A, 75A, 100A, 150A, 300A
0,2 S, 0,2, 0,5 S
0,5
5P, 10P
0.7 kOhm
0.1 Ohm
0.15 Ohm
300A
0,2 S, 0,2, 0,5 S
0,5
5P, 10P
-
-
-
80A, 400A
0,2 S, 0,2, 0,5 S
0,5
5P, 10P
0.1 kOhm
0.13 Ohm
0.17 Ohm
 
Instrument current transformer TL-10M-2-I-1 for the differential protection is available on request;
General view of the device shown in Figure 1;
 
Figure 1: General view of the instrument current transformer TL-10M-2-I-1
 
TL-10M-2-I-1 - Current transformer - Drawing.
 
Dimensions and weight of the device current transformer TL-10M-2-I-1 are listed in Table 2;
 
Table 2: Dimensions and weight of the device current transformer TL-10M-2-I-1
 
Rated primary current
Dimensions.
Weight
B
D
L
{0}L{/0}{1}1{/1}
H
5A to 15A
40mm
24mm
84mm
27.5 mm
27mm
29kg
20A-200A
35mm
24mm
84mm
27.5 mm
27mm
29kg
 
The transformers are manufactured in climatic design "UHL" and are intended for indoor use in:
Height above the sea level - no more than 1000 m.
- Ambient temperature with the heat the air inside the switchgear - from -60 ° C to +55 ° C;
- Environment explosive, without dust, reactive gases and vapors in concentrations destroy metal and insulation;
- Working position - any;
- Instruments earthquake resistant when exposed to earthquake intensity 8 points on the MSK-64 at the facility level above ground level up to 70m;
- Appliances intended to be sold in AS, with class security for 3H-001 NP-97 and 2 seismic category for NP-031-01;
- Devices comply with immunity to electromagnetic interference to influence the magnetic field of industrial frequency;
- Equipment CT TL-10M-2-I-1 satisfy the standards of industrial radio Class A, Group 1;
In current transformers may be used to account for the secondary windings, Class 0,2 S and 0,5 S with the value of the secondary load below 25% of nominal;
The minimum weight for a current transformer winding device TL-10M-2-I-1 precision class 0,2 S and 0,5 S is 1B · A;
The certificate on the current transformers with secondary windings for accounting accuracy classes 0,2 S and 0,5 S indicates the measured current and the angular error at rated secondary burden 1B · A;
Can manufacture transformers with different transformation ratios of secondary windings;
The manufacturer guarantees that the quality of the instrument current transformer TL-10M-2-I-1 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.

Photos: TL-10M-2-I-1

TL-10M-2-I-1 transformer image.
TL-10M-2-I-1 transformer image.
TL-10M-2-I-1 transformer scheme.
TL-10M-2-I-1 transformer scheme.


Яндекс цитирования