Radiometric devices >> selective voltmeters, voltage disturbance recorders and instrumentation antennas

SMV 7

49 999 RUB
19 999 UAH
available:
1 piece

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Selective microvoltmeter SMV 7

Also, this device can be called: SMV7, SMV-7.

SMV 7 selective microvoltmeter - meters interference voltage - sensitive heterodyne receivers.

Used SMV 7 to measure high voltage sinusoidal and quasi-pulsed measurement interference voltages.

With measuring type antennas DP 3/ATR 2, DP 1/ATR 2 or LPA1/ATR2 - can be used as an instrument for measuring the field strength of radio interference.

Specifications SMV 7:

Frequency Range - 30 MHz to 300 MHz.

Subranges:

- From 30 MHz to 66 MHz;

- From 66 MHz to 142 MHz;

- From 142 MHz to 300 MHz.

Accuracy after calibration of the frequency scale at the next mark - ±(3∙10-3·fe+200 kHz).

Frequency labels - n·5MHz; n·20MHz.

Frequency instability without recalibration:

- At power supply voltage variation of ±10% - less than 2∙10-5 ;

- Voltage fluctuations batteries (12 V) - no more than 4∙10 -4 ;

- Battery voltage fluctuations (16 V to 30 V) - no more than 2∙10-5 ;

- In a changing environment - no more than 2∙10-4 ±10 kHz/° C.

Types of reference voltage microvoltmeter SMV 7:

- AV I - mean value of AM-signals, 20 dB;

- AV II - the average value of AM-signals, 40 dB;

- QP - quasi-peak value;

- P - peak value.

Limit voltage measurement - in steps of 5 dB and 10 dB.

AV I; P

Limit:

- 0 dB to 125 dB;

- From -5 dB to 120 dB.

Lowest voltage for full deflection indicating instrument - 5 dB, 10 dB.

Voltage for the signal/noise ratio of 6 dB at 20 kHz bandwidth - less than 1 mV.

AV II

Lowest voltage for full deflection indicating instrument - 20 dB.

QP

Limit:

- For impulse voltage - 10 dB to 85 dB (115 dB);

- For sinusoidal voltages - from 10 dB to 85 dB (125 dB).

Lowest voltage for full deflection indicating instrument - 10 dB.

Bandwidth SMV 7 - 20 kHz, 120 kHz.

Attenuation:

- An intermediate frequency - not less than 80 dB;

- Mirror channel - not less than 80 dB.

Measuring the attenuation limit - 95 dB.

Additional measurement error voltage - ±0,5 dB.

Output for headphone connection - socket 4 mm.

Intermediate frequency Microvoltmeter SMV 7 - 1,67 MHz.

Oscilloscope:

Voltage during blackout indicator - not less than 0,5 V.

Frequency range - from 0 to 50 kHz.

Type of connection - a tank RF connector 50 Ohm (1/3, 3).

Generator:

Output Voltage - 95±2 dB.

Fluctuation in output voltage with frequency tuning - not less than 1 dB.

Output Impedance - 50 Ohm.

The exit of the output resistance - not more than 1,67.

Type of connection - a tank RF connector 50 Ohm (N).

Voltage adjustment device to ±100 kHz - ±2 V.

Shielding microvoltmeter SMV 7:

- At position 0 dB RF divider - not less than 90 dB;

- At TGL 20885/02 - not less than 60 dB.

Type of connection - a tank RF connector 50 Ohm (1/3, 3).

Weight - 22 kg.

Dimensions - 550x200x400 mm.

Operating conditions SMV 7:

Operating temperature range - from -30º C to +50º C.

Maximum allowable vapor pressure - 35 Torr.

Food:

- From - 220 V;

- Battery - 12±1 V, 16 V and 30 V.

Power consumption - 15·A.

Current consumption - ±300 mA.

Protection class - I.

The manufacturer provides a guarantee of compliance selective microvoltmeter SMV 7 all the technical requirements if the consumer terms and conditions of use, storage and transportation, installed documentation manuals.

Photos: SMV 7

SMV 7 device image.
SMV 7 device image.
SMV 7 front view.
SMV 7 front view.
SMV 7 side view.
SMV 7 side view.
SMV 7 rear view.
SMV 7 rear view.
SMV 7 overhead view.
SMV 7 overhead view.
SMV 7 bottom view.
SMV 7 bottom view.