Digital panel meter dc SCH00, SCH01, SCH02, SCH02.01, SCH72, SCH96, SCH120
 
Digital panel meter dc SCH00, SCH01, SCH02, SCH02.01, SCH72, SCH96, SCH120 is designed to measure current or voltage in DC.
 
Technical characteristics of the instrument digital panel meters dc SCH00, SCH01, SCH02, SCH02.01, SCH72, SCH96, SCH120:
 
Digital panel meters dc SCH00, SCH01, SCH02, SCH02.01, SCH72, SCH96, SCH120 can be used in energy and other industries to control the electrical parameters. Devices digital panel meter dc SCH00, SCH01, SCH02, SCH02.01, SCH72, SCH96, SCH120 are odnopredelnymi and have designs on the design, measurement range, the number of decimal places, the supply voltage, the presence of the interface, color indicators, accuracy class.
 
Type
Dimensions / cutout in the panel, mm
The height of the sign, mm
The number of bits
SCH00
48h24h90mm/42h19mm
9mm
3.5
SCH01
96h24h90mm/90h18mm
10mm
3.5
SCH02
96h48h145mm/90h42mm
20mm
3.5
14mm
4,0
SCH02.01
96h48h90mm/90h42mm
20mm
3.5
SCH72
72h72h100mm/68h68mm
14mm
3.5
SCH96
96h96h100mm/92h92mm
20mm
3.5
14mm
4,0
SCH120
120h120h100mm/112h112mm
20mm
3.5 and 4.0
Operating conditions
Operating Temperature Range ...... from +5 ° C to +50 ° C
Humidity of not more than ........... 80% at +25 º C
 
Technical characteristics of the instrument digital panel meter dc SCH00, SCH01, SCH02, SCH02.01, SCH72, SCH96, SCH120
Decimal 3.5
Decimal 4.0
The maximum range of indications
± 1999
± 10 000
The number of digital displays
4
5
Accuracy class instrument digital panel meter dc SCH00, SCH01, SCH02, SCH02.01, SCH72, SCH96, SCH120
0.2 or 0.4
0.1 or 0.2
Power consumption with supply voltage of the DC, no more
2B ∙ A
2.5 A ∙
Power consumption with supply voltage of the AC, no more
5.5 A ∙
Degree of protection devices digital panel meter dc SCH00, SCH01, SCH02, SCH02.01, SCH72, SCH96, SCH120 on the front panel
IP40
Conversion time, not more
1.5 with
Galvanic isolation of input circuits
No
is
Electrical isolation of Nutrition
is
(Except SCH00)
is
The presence of the RS485 interface
No
is
The rate of exchange of information via interface RS485, baud
 
4800, 9600,
19200, 38400
Maximum allowable overload of the input signal (duration)
150% (1 minute)
Input impedance instrument digital panel meter dc SCH00, SCH01, SCH02, SCH02.01, SCH72, SCH96, SCH120 voltage measurement
1 M
The voltage drop across the device for measuring the current, no more than:
for ranges 2mA, 20mA, 100mA, 200mA, 2000mA, 2A.
for measuring ranges 5mA, 10mA, 50mA, 500mA, 1000mA, 1A.
 
 
200mV
 
100mV
 
 
200mV
 
100mV
 
Type of scale devices digital panel meter dc SCH00, SCH01, SCH02, SCH02.01, SCH72, SCH96, SCH120
Status indicators
(By jumpers on the rear panel)
"%"
H=48 km
Ordered (scale range corresponds to the order)
OFF
OFF
Normalizing (scale range corresponds to the maximum range of reading ± 10000.*)
ON
ON
Interest (scale range ± 100.0 *)
ON
OFF
Line (scale range corresponds to a range of input signal)
OFF
ON
* - For normalizing the percentage of scales and is consistent with the position of the point.
 
Wiring device digital panel meter dc SCH00, SCH01, SCH02, SCH02.01, SCH72, SCH96, SCH120 by the screw.The cross section of wires that are connected directly to the terminals, not more than 1.5 mm 2 for the devices SCH00, SCH01, SCH02.01 and not more than 2.0 mm 2 for the devices SCH02, SCH72, SCH96, SCH120.
 
Example of ordering
SCH01 device, measuring range, 2A rated voltage 75mV shunt, number of decimal digits 3,5, 5V DC, green indicators, accuracy class 0.2
Sch01-2A/75mV-3 ,5-5V-Z, accuracy class 0.2 specifications 25-7504.194-2006
SCH96 device, measuring range 20 mA, the number of decimal places to 3.5 V supply voltage from 85V to 242V AC 50Hz or 100V to 265V of DC, the red indicator, accuracy class 0.4
SCH96-20mA-3 ,5-220VU-K, accuracy class 0.4 specifications 25-7504.194-2006
SCH120 device, measuring range, 2000A, rated voltage of 150mV shunt, the number of digits 4,0, supply voltage 12V DC, red indicators, accuracy class 0.2
Sch120-2000A/150mV-4 ,0-12V-K, accuracy class 0.2 TU 25-7504.194-2006

Photos: Shch00, Shch01, Shch02, Shch02.01, Shch72, Shch96, Shch120

SCH02.01 50V voltmeter image.
SCH02.01 50V voltmeter image.
SCH02.01 100A ammeter image.
SCH02.01 100A ammeter image.
SCH02.01 50V front view.
SCH02.01 50V front view.
SCH02.01 50V side view.
SCH02.01 50V side view.
SCH02.01 50V rear view.
SCH02.01 50V rear view.
SCH02.01 50V overhead view.
SCH02.01 50V overhead view.
SCH02.01 50V bottom view.
SCH02.01 50V bottom view.


Яндекс цитирования