Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> devices series of Sh45...

SH4513

For order is possible effectively delivery of any quantity.
Microammeter SH4513 (SH-4513, SH 4513)
 
Microammeter SH4513 is designed to measure the temperature and position control.
The instrument consists of instruments: the transducer - resistance thermometer; milliammeter M450, P451 conversion unit.
 
Technical characteristics of the devices microammeter SH4513:
 
Measurement range:
- Temperature - 200 º C-+500 º C;
- Resistance - 7.95 Ohm-283, 80 ohms;
Accuracy class - 1.0;
Acceptable basic error microammeter SH4513 device measuring range - ± 1,0% of the measuring range;
Measurement ranges microammeter SH4513 device are shown in Table 1;
 
Table 1 Ranges device microammeter SH4513
Graduirovochaya characteristic
Measuring range
Temperature, º C
Resistance Ohm
GR. 20
0 º C-300 º C
0 º C-400 º C
0 º C-500 º C
0 º C-650 º C
300 º C-650 º C
10.00 21 ohm, 38 ohm
10.00-24 ohm, 94 ohm
10.00-28 ohm, 38 ohm
10.00-33 ohm, 32 ohm
21.38-33 ohm, 32 ohm
GR. 21
-200 º C - 70 º C
-120 º C-+30 º C
-70 º C-+180 º C
-50 º C-+50 º C
0 º C and 100 º C
0 º C-150 º C
0 º C-200 º C
0 º C-300 º C
0 º C-400 º C
0 º C-500 º C
200 º C-500 º C
7.95 W-3, 08 ohm
23.63 61 ohm, 45 ohm
33.08-77 ohm, 99 ohm
36.80-55 ohm, 06 ohm
46.00-63 ohm, 99 ohm
46.00-72 ohm, 78 ohm
46.00-81 ohm, 43 ohm
46.00-98 ohm, 34 ohm
46.00 W-114, 72 ohm
46.00 W-130, 52 ohms
81.43 W-130, 55 ohm
GR. 22
-200 º C - 70 º C
-120 º C-+30 º C
-90 º C-+50 º C
-70 º C-+180 º C
-50 º C-+50 º C
-25 º C-+25 º C
0 º C-50 º C
0 º C and 100 º C
0 º C-150 º C
0 º C-200 º C
0 º C-300 º C
0 º C-400 º C
0 º C-500 º C
200 º C-500 º C
17.28-71 ohm, 91 ohm
51.38 W-111, 85 ohms
63.75 W-119, 70 Ohm
71.91 W-169, 54 ohm
80.00 W-119, 70 Ohm
90.04 W-109, 88 ohm
100.00 W-119, 70 Ohm
100.00 W-139, 10 ohm
100.00 W-158, 21 ohm
100.00 W-177, 03 ohm
100.00 W-213, 79 ohm
100.00 W-249, 38 ohm
100.00 W-283, 80 ohms
100.00 W-283, 80 ohms
GR. 23
-50 º C-0 º C
-50 º C-+50 º C
-50 º C-+100 º C
0 º C-50 º C
0 º C and 100 º C
0 º C-150 º C
0 º C to 180 º C
50 º C and 100 º C
41.71-53 ohm, 00 ohm
41.71-64 ohm, 29 ohm
41.71-45 ohm, 58 ohm
53.00-64 ohm, 29 ohm
53.00-75 ohm, 58 ohm
53.00-86 ohm, 87 ohm
53.00-93 ohm, 64 ohm
64.29-75 ohm, 58 ohm
GR. 24
-50 º C-0 º C
-50 º C-+50 º C
-50 º C-+100 º C
-25 º C-+25 º C
0 º C-25 º C
0 º C-50 º C
0 º C and 100 º C
0 º C-150 º C
0 º C to 180 º C
50 º C and 100 º C
78.70 W-100, 00 ohm
78.70 W-121, 30 ohm
78.70 W-142, 60 ohm
89.35 W-110, 65 ohm
100.00 W-110, 65 ohm
100.00 W-121, 30 ohm
100.00 W-142, 60 ohm
100.00 W-163, 90 Ohm
100.00 W-176, 78 ohm
100.00 W-142, 60 ohm
 
Calming the mobile device of the microammeter SH4513 - no more than 7c;
Warm-up time - 30 minutes;
Operating position ammeter device SH4513 - vertical;
Changing readings caused deviation of ambient temperature from normal (within the operating temperature range) for every 10 K, does not exceed ± 1,0%; under the influence of a constant external magnetic field of 400 A / m, formed by a DC or AC, 50 Hz - no more than ± 0,5% of the measuring range;
Mean time to failure of the device microammeter SH4513 - not less than 24,000 hours;
Dimensions of devices:
- Milliammeter M450 - 80h160h230mm;
- Conversion unit P451 - 112h164h260mm;
Weight of the device included with the device microammeter SH4513:
- Milliammeter M450 - 1.6 kg;
- Conversion unit P451 - 2.3 kg;
Mean time to failure of the device microammeter SH4513 - not less than 24,000 hours;
Average life - at least 6 years;
The manufacturer guarantees that the quality of the instrument microammeter SH4513 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.
 