Electrical measuring instruments >> voltmeters

S5022

8 999 RUB
3 150 UAH
available:
6 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Voltmeter S5022 (S-5022, S 5022, c-5022, c 5022, c5022)
Voltmeter S5022 is designed to measure AC voltage in a wide range of frequencies and DC voltage. Accuracy Class 0.5 voltmeter S5022. Final value of the measuring range 75V.

   
    Voltmeters S5022 intended to measure alternating voltage in a wide range of frequencies and DC voltage.
    Voltmeters S5022 are designed for use in moderate climate in enclosed dry heated rooms at the ambient temperature of 10 to 35 ° C and a relative humidity of 80% (at 25 ° C);
    Voltmeters S5022 T4.1 - tropical version - in dry and humid tropical climate in closed rooms with air conditioned or partially air-conditioned at the ambient temperature from 1 to 40 ° C and a relative humidity of 80% at 25 ° C and at lower temperatures no condensation (at higher temperatures, relative humidity below) in accordance with GOST 15150-69
    Technical data
    Accuracy Class 0.5 voltmeter S5022 according to GOST 8711-78. Additional error S5022 voltmeter, frequency deviation caused by the upper limit of the normal range of frequencies up to any frequency in the working frequency range does not exceed ± 0,5% of the final value of the measuring range.
    Time for reading voltmeter S5022 6. Voltmeter S5022 can be used for measurements at frequencies above the work area. Frequency limits and measurement errors are shown in Table 1. Input impedance voltmeter DC S5022 more than 10 10 ohms.
    Dining lighting circuit voltmeter is provided from AC power supply (220 +22), frequency 50-60Hz through a step-down transformer, can be combined with a voltmeter S5022, either on AC or DC voltage of 4 V. Dimensions: voltmeter 205h290h135 mm transformer housing - 65h85h45 mm. Weight voltmeter S5022 is not more than 4 kg transformer not more than 0.5 kg.
 

Modi-
fic-
tion of the current-
meter

The final
tion know-

ledge
chenie range
Area measu-

rement
tions

Normal-
tial region, Hz

Opera-

ting freque-

ncy range, MHz

Frequency in MHz at the border of measurement error in the range

Input capa-

citance, pF, not more

Rust
yazhka D GOST 9444-74
Tension-
tensile-
zhek, H
From -0.5 to +1.5% of full scale of the measuring range From -0.5 to 2.5% of the final value of the measuring range
S502 / 2 In July 5 45 to 1.10 6 More than 1 to 2.5 Over 2.5 to 3.5 Over 3.5 to 5 35 0.4 0.98

Photos: S5022

S5022 voltmeter image.
S5022 voltmeter image.
S5022 panel view.
S5022 panel view.
S5022 side view (terminals, switch).
S5022 side view (terminals, switch).
S5022 side view.
S5022 side view.
S5022 side view.
S5022 side view.
S5022 bottom view.
S5022 bottom view.


Яндекс цитирования