Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> devices series of MVU6...

MVU6-42S

999 RUB
250 UAH
available:
85 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Millivoltmeter MVU6-42C (MVU642C, MVU6 42C, MVU-6-42C)
 
Millivoltmeter MVU6-42C is designed for temperature measurement complete with thermoelectric resistance thermometers all calibration parameters and light alarm at the exit temperature of the specified range.
Includes additional gain block BU-21.
 
Technical characteristics of the devices millivoltmeters MVU6-42C:
 
Measurement range:
- Temperature - 50 º C-500 º C;
- Resistance - 10 ohm-283, 80 ohms;
Accuracy class - 1.0;
Acceptable basic error of the instrument millivoltmeter MVU6-42C in the measuring range - ± 1,0% of the measuring range;
Hysteretic error does not exceed the absolute value of the admitted basic error;
Measurement ranges device millivoltmeter MVU6-42C and calibration characteristics are given in Table 1;
 
Table 1 Ranges device millivoltmeter MVU6-42C
Graduirovochaya characteristic Measurement range
Temperature, º C Resistance, Ohm
GR. 20 0 º C-300 º C
0 º C-400 º C
0 º C-500 º C
0 º C-650 º C
300 º C-650 º C
10.00 21 ohm, 38 ohm
10.00-24 ohm, 94 ohm
10.00-28 ohm, 38 ohm
10.00-33 ohm, 32 ohm
21.38-33 ohm, 32 ohm
GR. 21 -200 º C - 70 º C
-120 º C-+30 º C
-70 º C-+180 º C
-50 º C-+50 º C
0 º C and 100 º C
0 º C-150 º C
0 º C-200 º C
0 º C-300 º C
0 º C-400 º C
0 º C-500 º C
200 º C-500 º C
7.95 W-3, 08 ohm
23.63 61 ohm, 45 ohm
33.08-77 ohm, 99 ohm
36.80-55 ohm, 06 ohm
46.00-63 ohm, 99 ohm
46.00-72 ohm, 78 ohm
46.00-81 ohm, 43 ohm
46.00-98 ohm, 34 ohm
46.00 W-114, 72 ohm
46.00 W-130, 52 ohms
81.43 W-130, 55 ohm
GR. 22 -200 º C - 70 º C
-120 º C-+30 º C
-90 º C-+50 º C
-70 º C-+180 º C
-50 º C-+50 º C
-25 º C-+25 º C
0 º C-50 º C
0 º C and 100 º C
0 º C-150 º C
0 º C-200 º C
0 º C-300 º C
0 º C-400 º C
0 º C-500 º C
200 º C-500 º C
17.28-71 ohm, 91 ohm
51.38 W-111, 85 ohms
63.75 W-119, 70 Ohm
71.91 W-169, 54 ohm
80.00 W-119, 70 Ohm
90.04 W-109, 88 ohm
100.00 W-119, 70 Ohm
100.00 W-139, 10 ohm
100.00 W-158, 21 ohm
100.00 W-177, 03 ohm
100.00 W-213, 79 ohm
100.00 W-249, 38 ohm
100.00 W-283, 80 ohms
100.00 W-283, 80 ohms
GR. 23 -50 º C-0 º C
-50 º C-+50 º C
-50 º C-+100 º C
0 º C-50 º C
0 º C and 100 º C
0 º C-150 º C
0 º C to 180 º C
50 º C and 100 º C
41.71-53 ohm, 00 ohm
41.71-64 ohm, 29 ohm
41.71-45 ohm, 58 ohm
53.00-64 ohm, 29 ohm
53.00-75 ohm, 58 ohm
53.00-86 ohm, 87 ohm
53.00-93 ohm, 64 ohm
64.29-75 ohm, 58 ohm
GR. 24 -50 º C-0 º C
-50 º C-+50 º C
-50 º C-+100 º C
-25 º C-+25 º C
0 º C-25 º C
0 º C-50 º C
0 º C and 100 º C
0 º C-150 º C
0 º C to 180 º C
50 º C and 100 º C
78.70 W-100, 00 ohm
78.70 W-121, 30 ohm
78.70 W-142, 60 ohm
89.35 W-110, 65 ohm
100.00 W-110, 65 ohm
100.00 W-121, 30 ohm
100.00 W-142, 60 ohm
100.00 W-163, 90 Ohm
100.00 W-176, 78 ohm
100.00 W-142, 60 ohm
 
Under the terms of mechanical stress, the device belongs to the stability;
Failure to return the pointer device millivoltmeter MVU6-42C to zero - not more than 0.6 mm;
External resistance - 5 ohms;
Operating position device millivoltmeter MVU6-42C - Vertical;
Settling time moving part - no more than 4s;
The measuring system of the device millivoltmeter MVU6-42C - magnetoelectric type of uniform one-sided scale;
Scale length - 130mm;
Changing the millivolt readings MVU6-42C caused deviation of ambient temperature from normal (within the operating temperature range) for every 10 K, does not exceed ± 0,8%; under the influence of a constant external magnetic field of 400 A / m, formed a DC or AC frequency 50Hz - less than ± 0,5% of the measuring range;
Dimensions:
- Device M1734 - 30h160h272, 5mm;
- HEAD UNIT - 75h110h75mm;
- Bracket - 182h30h237mm
Weight:
- Device M1734 - 1.3 kg;
- Unit increase - 0.6 kg;
- Mounting bracket - 0.3 kg;
Mean time to failure of the device millivoltmeter MVU6-42C - no less than 20,000 hours;
Average life - at least 6 years;
The manufacturer guarantees that the quality of the instrument millivoltmeter MVU6-42C technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.