Millivoltmeter M42104 (M 42104, M-42104)
 
Millivoltmeter M42104 designed to measure voltage in dc circuits.
Accuracy class - 1.5, 2.5;
Dimensions - 80h80h50mm;
Vibration, shock and vibration resistant.
 
Technical characteristics of the devices millivoltmeters M42104:
 
Instruments used in the tropical version at - from -10 º C to +60 º C;
Relative humidity - 98% at 35 º C;
Accuracy class of the instrument millivoltmeter M42104 - 1.5, 2.5;
Basic error - ± 1,5 - for devices with an accuracy of 1,5, ± 2,5% - for devices with accuracy class 2.5;
Variation millivolt readings M42104 - 2.25% - for units with an accuracy of 1.5, 3.75% - for units with an accuracy class 2.5;
Failure to return the arrows to zero - not more than 1.0 mm - for devices with an accuracy of 1.5, 1.7 mm - for devices with accuracy class 2.5;
Measurement range of devices millivoltmeter M42104:
- One-sided scale - 0mV-25mV, 0mV-45mV, 0mV-75mV, 150mV, 0mV, 0mV-300mV, 500mV, 0mV, 0mV-750mV, 0mV-1000mV;
- Double-sided scale - 25mV, 0mV-25mV, 45mV, 0mV-45mV, 75mV, 0mV-75mV, 150mV, 150mV-0mV, 300mV-300mV-0mV, 500mV-500mV-0mV, 750mV-750mV-0mV, 1000mV-0mV -1000mV;
Current full deflection - 3mA;
Switching on millivolt M42104 with calibrated wires;
Operating position of the device - the horizontal and vertical;
Settling time moving part - 4c;
Changing the millivolt readings M42104 caused deviation of ambient temperature from normal to any (within the operating temperature range) for every 10 K, does not exceed ± 0,8% - for devices with an accuracy of 1,5, ± 1,2% - for instruments with an accuracy of 2.5, under the influence of an external magnetic field of 400 A / m - less than ± 1,0% - for devices with an accuracy of 1,5, ± 2,5% - for devices with accuracy class 2.5;
The length scale of the instrument millivoltmeter M42104 - 69mm;
Dimensions - 80h80h50mm;
Unit weight millivoltmeter M42104 - 0.20 kg;
Time to failure - at least 65,500 hours;
The manufacturer guarantees that the quality of the instrument millivoltmeter M42104 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.