M333K ammeter, voltmeter M333K, M333K microammeter, milliammeter M333K, M333K millivolmetr (M 333 K, M-333-K , M333 K, M333-K, M 333K, M-333K)
M333K ammeter, voltmeter M333K, M333K microammeter, milliammeter M333K, M333K millivolmetr designed to measure and regulate current and voltage in DC networks.
Dimensions - 120h120h160mm.
Accuracy Class - 2.5, 1.5.
Resistant to shaking, vibration.
 
Technical characteristics of the devices M333K ammeters, voltmeters, M333K, M333K microammeter, milliammeter M333K, M333K millivolmetry:
 

Table 1

The final value of measuring range
Accuracy class

Burst Tolerance contact device,%

Device switch
10mkA
25mkA
5mkA-0-5mkA
12,5mkA-0-12,5mkA
2,5
4,0%
Direct
50mkA
100mkA
200mkA
300mkA
500mkA
1000mkA
25mkA-0-25mkA
50mkA-0-50мкА
100mkA-0-100mkA
150mkA-0-150mkA
250mkA-0-250mkA
500mkA-0-500mkA
1,5
2,0%
Direct
5mA
10mA
20mA
2,5mA-0-2,5mA
5mA-0-5mA
10mA-0-10mA
1,5
2,0%
Direct
15mV
30mV
45mV
50mV
60mV
75mV
100mV
200mV
300mV
400mV
500mV
600mV
7,5mV-0-7,5mV
15mV-0-15mV
-
25mV-0-24mV
30mV-0-30mV
-
50mV-0-50mV
100mV-0-100mV
150mV-0-150mV
200mV-0-200mV
250mV-0-250мВ
300mV-0-300мВ
1,5
2,0%
With calibrated conductors
 
The final values ​​of range and accuracy class instruments M333K ammeter, voltmeter M333K, M333K microammeter, milliammeter M333K, M333K millivolmetr given in Table 1.
Settling time moving part - no more than 4s.
Operating position devices M333K ammeter, voltmeter M333K, M333K microammeter, milliammeter M333K, M333K millivolmetr - vertical, with a deviation of no more than ± 2.
Scale length - 90 mm. 
Change the readings of ammeter M333K, M333K voltmeter, microammeter M333K, M333K milliammeter, millivolmetr M333K caused by the deviation of the ambient temperature from normal, does not exceed ± 1,2% for every 10 K, under the influence of an external magnetic field of 400A / m - not more than ± 1,0%;
- Rejecting power-supply voltage from -15% to +10% of nominal - no more than ± 1,5%, the frequency of the power supply of ± 2% of nominal - no more than ± 1,0%;
- Rejecting devices M333K ammeter, voltmeter M333K, M333K microammeter, milliammeter M333K, M333K millivolmetr from the working position of 10 º - did not exceed ± 2,5% (for instruments of accuracy class 2.5) and ± 1,5% (for instruments of class accuracy of 1.5).
Food contact device by AC 220V 50Hz.
Weight devices M333K ammeter, voltmeter M333K, M333K microammeter, milliammeter M333K, M333K millivolmetr - 2.0 kg.
Working hours M333K devices ammeter, voltmeter M333K, M333K microammeter, milliammeter M333K, M333K millivolmetr to failure - at least 24 000 hours.
 