Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> narrow-profile DC

M1731KL

17 535 RUB
7 014 UAH
available:
51 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
M1731KL ammeter, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL (M 1731 KL, M-1731-KL, M1731 KL, M1731-KL, M 1731KL, M-1731KL)
 
M1731KL ammeter, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL designed to measure DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
Dimensions - 160h30h275mm.
Accuracy class - 0.5.
Narrow, two-position contact with the left contact.
 
Technical characteristics of the devices M1731KL ammeters, voltmeters M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeters M1731KL:
 
Devices with a light pointer are part of a harmonized set of analog signaling devices contact ASA.
Devices M1731KL ammeter, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, M1731KL millivoltmeter are used for measuring DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
The devices can be used to work in a set of transducers (sensors) SHGs.
Devices M1731KL ammeter, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL designed for flush mounting on panels and boards fixed installations.
The instruments are the five modifications:
- Pointing - A;
- Signaling - C;
- Three-pin - K;
- Pin DIP with the right contact - KP;
- Pin DIP with the left contact - CR.
Devices M1731KL ammeter, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL used to work at ambient temperatures from -30 º C to +50 ° C and relative humidity up to 90% (at 30 ° C).
Execution of regular and tropical.
With the direct inclusion of the instrument M1731KL ammeter, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, M1731KL millivoltmeter circuit in time and reassurance from 3 seconds to 4 seconds beyond measure up - 5mkA; 5mkA-0mkA-5mkA; 10mkA; 10mkA-0mkA-10mkA; 30mkA ; 30mkA-0mkA-30mkA; 50mkA.
- At the time sedation to 3 seconds beyond measure - 50mkA-0mkA-50mkA; 100mkA; 100mkA-0mkA-100mkA; 150mkA; 150mkA-0mkA-150mkA; 300mkA; 300mkA-0mkA-300mkA; 500mkA; 500mkA-0mkA-500mkA;
- At the time calm 1.5s limits of measurement - 1 mA, 1 mA, 0 mA-1 mA, 5 mA, 0 mA-5 mA-5 mA, 10 mA, 0 mA-10 mA-10 mA, 20 mA, 0 mA-20 mA to 20 mA, 30 mA, 0 mA-30 mA-30 mA , 50mA, 50mA, 50mA, 0 mA-, 100mA, 100mA 100mA, 0 mA-, 150mA, 150mA 150mA, 0 mA-, 300mA, 300mA 300mA, 0 mA-, 500mA, 500mA 500mA, 0 mA, and 1A 1A 0A 1A, 2A ; 2A-0A-2A, 5A, 5A-0A-5A.
When the device is turned M1731KL ammeter, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL in circuit with an external shunt 75mV at the time and calm the 1.5 second measurement limits are - 10A, 10A-0A-10A, 20A, 20A-0A-20A , 30A, 30A-0A-30A, 50A, 50A-0A-50A, 100A, 100A-100A-0s, 150A, 150A-150A-0s, 200A, 200A-200A-0s, 300A, 300A-300A-0s; 500A , 500A-500A-0s, 750A, 750A-750A-0s and 1kA, 1kA-0kA-1kA, 2kA, 2kA-0kA-2kA, 3kA, 3kA-0kA-3kA; 4kA; 4kA-0kA-4kA; 5kA; 5kA -0kA-5kA; 6kA; 6kA-0kA-6kA.
The voltage drop across the microammeter, milliammeter and an ammeter with internal shunts less than 120mV.
An optional devices M1731KL ammeter, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL the limits of measurement from 1mA above 10V and from above and can be manufactured in vertical version, as well as for mounting on panels and boards with specified when ordering a tilt angle .
At rated current 0.2 mA and 4 seconds of time calming devices measuring range ammeter M1731KL, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL - 10 mV, 10 mV-10mV 0mV-, 20mV, 20mV, 20mV 0mV-, 45mV, 45mV, 0mV -45mV, 50mV, 50mV, 50mV 0mV-, 1B, 1B-0B-1B, 1.5 V, 1.5 V-0 V-1, 5V, 3V, 3V-0V-3V, 7.5V, 7.5V, 0V -7.5 V.
At rated current 1.0 mA and 1.5 seconds of time calming devices measuring range ammeter M1731KL, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL - 75mV and 75mV, 75mV 0mV-.
At rated current 0.2 mA and 2.5 seconds of time calming measuring range - 100mV, 100mV, 100mV 0mV-, 200mV, 200mV, 200mV 0mV-, 500mV, 500mV, 500mV 0mV-.
At rated current 1.0 mA and 1.5 seconds of time calming devices measuring range ammeter M1731KL, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL - 10V, 10V-0V-10V, 15V, 15V-0V-15V, 30V, 30V -0V-30V, 50V, 50V-0V-50V, 75V, 75V-0V-75V, 150V, 150V, 0V, 250V, 250V-0V-250V, 400V-0V-400V, 600V, 600V, 600V-0V-.
For microammeter with a limit of measurement 5mkA settling time is determined by external resistor is not less than 8 ohms.
The main error of the instrument M1731KL ammeter, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL is ± 0,5%.
Burst Tolerance photocontact device of the instrument is ± 1,5%.
Operating position of ammeter instrumentation M1731KL, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL - horizontal.
The length scale devices - 120mm.
Changing the readings M1731KL ammeter, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL caused by ambient temperature deviation from the normal (ranging from -30 º C to +50 ° C) for every 10 degrees less than ± 0,8% for instruments accuracy class 1.0 and ± 0,4% - for instruments of accuracy class 0.5;
- Under the influence of external magnetic field strength of 400 A / m - not more than ± 0,5%; rejecting the instrument at 5 ° in any direction from the working position - does not exceed ± 1,0% for instruments M1731KL ammeter, voltmeter M1731KL, M1731KL microammeter, milliammeter M1731KL, M1731KL millivoltmeter.
Output current in photoconductive devices to modify, CC and CR varies from 30mkA (no more) in a dark state to 250mkA (at least) in the illuminated state when powered from a voltage source of 10V and heater voltage lamp fixture no more than 5V.
Weight devices ammeter M1731KL, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL - 1.3 kg;
Unit dimensions with cover to the adjustment of filters - mm 160h35h270.
Weight - 1.4 kg.
Dimensions staples - 182h30h230mm.
Weight - 0.3 kg.
Devices M1731KL ammeter, voltmeter M1731KL, microammeter M1731KL, milliammeter M1731KL, millivoltmeter M1731KL have a flat cast aluminum alloy, closed the lid.
The measuring mechanism - the magneto system.
 


Яндекс цитирования