Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> narrow-profile DC

M1730M

17 535 RUB
7 014 UAH
available:
339 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
M1730M ammeter, voltmeter M1730M, M1730M microammeter, milliammeter M1730M, M1730M millivoltmeter (M 1730 M, M-1730-M, M1730 M, M1730-M, M 1730M, M-1730M)
 
M1730M ammeter, voltmeter M1730M, M1730M microammeter, milliammeter M1730M, M1730M millivoltmeter are used to measure DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
Dimensions - 160h30h275mm.
Accuracy Class - 1.0.
Narrow.
 
Technical characteristics of the devices M1730M ammeters, voltmeters M1730M, M1730M microammeter, milliammeter M1730M, millivoltmeters M1730M:
 
Devices with a light indicator are part of a harmonized set of analog to signal pin devices ASA.
Devices M1730M ammeter, voltmeter M1730M, M1730M microammeter, milliammeter M1730M, M1730M millivoltmeter are used for measuring DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
The devices can be used to work in a set of transducers (sensors) SHGs.
Devices M1730M ammeter, voltmeter M1730M, M1730M microammeter, milliammeter M1730M, millivoltmeter M1730M designed for flush mounting on panels and boards fixed installations.
The instruments are the five modifications:
- Pointing - A;
- Signaling - C;
- Three-pin - K;
- Pin DIP with the right contact - KP;
- Pin DIP with the left contact - CR.
Devices M1730M ammeter, voltmeter M1730M, M1730M microammeter, milliammeter M1730M, M1730M millivoltmeter used to work at ambient temperatures from -30 º C to +50 ° C and relative humidity up to 90% (at 30 ° C).
Execution of regular and tropical.
With the direct inclusion of the instrument M1730M ammeter, voltmeter M1730M, M1730M microammeter, milliammeter M1730M, M1730M millivoltmeter circuit in time and reassurance from 3 seconds to 4 seconds beyond measure up - 5mkA; 5mkA-0mkA-5mkA; 10mkA; 10mkA-0mkA-10mkA; 30mkA ; 30mkA-0mkA-30mkA; 50mkA.
- At time calm to 3 seconds beyond measure - 50mkA-0mkA-50mkA; 100mkA; 100mkA-0mkA-100mkA; 150mkA; 150mkA-0mkA-150mkA; 300mkA; 300mkA-0mkA-300mkA; 500mkA; 500mkA-0mkA-500mkA;
- At time calm the limits of measurement 1.5 seconds - 1 mA, 0 mA-1mA 1mA-, 5 mA, 0 mA-5mA 5mA-, 10mA, 10mA, 0 mA-10 mA, 20mA, 20mA, 0 mA to 20mA, 30mA, 30mA, 0 mA-30 mA , 50mA; 50mA-50mA-0 mA, 100mA, 100mA, 100mA, 0 mA, 150mA, 150mA, 150mA, 0 mA, 300 mA, 300 mA 0 mA-300 mA-, 500mA, 500mA, 500mA and 0 mA-1A, 1A-0A-1A, 2A , 2A-0A-2A, 5A, 5A-0A-5A.
When the device is turned M1730M ammeter, voltmeter M1730M, M1730M microammeter, milliammeter M1730M, M1730M millivoltmeter in circuit with an external shunt 75mV at the time and calm the 1.5 second measurement limits are - 10A, 10A-0A-10A, 20A, 20A-0A-20A , 30A, 30A-0A-30A, 50A, 50A-0A-50A, 100A, 100A-100A-0s, 150A, 150A-150A-0s, 200A, 200A-200A-0s, 300A, 300A-300A-0s; 500A , 500A-500A-0s, 750A, 750A-750A-0s and 1kA, 1kA-0kA-1kA, 2kA, 2kA-0kA-2kA, 3kA, 3kA-0kA-3kA; 4kA; 4kA-0kA-4kA; 5kA; 5kA -0kA-5kA; 6kA; 6kA-0kA-6kA.
The voltage drop across microammeter, milliammeter and ammeter with internal shunts less than 120mV.
An optional devices M1730M ammeter, voltmeter M1730M, M1730M microammeter, milliammeter M1730M, M1730M millivoltmeter for measuring range of 1 mA and above, and from 10 V and above may be manufactured in vertical version, as well as for mounting on panels and boards with specified when ordering a tilt angle .
At rated current 0.2 mA and 4 seconds of time calming devices measuring range ammeter M1730M, M1730M voltmeter, microammeter M1730M, M1730M milliammeter, millivoltmeter M1730M - 10 mV, 10 mV-10mV 0mV-, 20mV, 20mV, 20mV 0mV-, 45mV, 45mV, 0mV -45mV, 50mV, 50mV, 50mV 0mV-, 1B, 1B-0B-1B, 1.5 V, 1.5 V-0 V-1, 5V, 3V, 3V-0V-3V, 7.5V, 7.5V, 0V -7.5 V.
At rated current 1.0 mA and 1.5 seconds of time calming devices measuring range ammeter M1730M, M1730M voltmeter, microammeter M1730M, M1730M milliammeter, millivoltmeter M1730M - 75mV and 75mV, 75mV 0mV-.
At rated current 0.2 mA and 2.5 seconds of time calming the limits of measurement - 100mV, 100mV, 0mV-100mV, 200mV, 200mV, 0mV-200mV, 500mV, 500mV, 0mV-500mV.
At rated current 1.0 mA and 1.5 seconds of time calming devices measuring range ammeter M1730M, M1730M voltmeter, microammeter M1730M, M1730M milliammeter, millivoltmeter M1730M - 10V, 10V-0V-10V, 15V, 15V-0V-15V, 30V, 30V -0V-30V, 50V, 50V-0V-50V, 75V, 75V-0V-75V, 150V, 150V, 0V, 250V, 250V-0V-250V, 400V-0V-400V, 600V, 600V, 600V-0V-.
To limit measurements with microammeter 5mkA settling time is determined by the external resistance is not less than 8 ohms.
The main error of the instrument M1730M ammeter, voltmeter M1730M, M1730M microammeter, milliammeter M1730M, M1730M millivoltmeter is ± 1,0%.
Burst Tolerance photocontact device of the instrument is ± 1,5%.
Operating position of ammeter instrumentation M1730M, M1730M voltmeter, microammeter M1730M, M1730M milliammeter, millivoltmeter M1730M - horizontal.
The length scale devices - 120mm.
Changing the readings M1730M ammeter, voltmeter M1730M, M1730M microammeter, milliammeter M1730M, millivoltmeter M1730M caused by ambient temperature deviation from the normal (ranging from -30 º C to +50 ° C) for every 10 degrees less than ± 0,8% for instruments accuracy class 1.0 and ± 0,4% - for instruments of accuracy class 0.5;
- Under the influence of external magnetic field strength of 400 A / m - not more than ± 0,5%; rejecting the instrument at 5 ° in any direction from the working position - does not exceed ± 1,0% for instruments M1730M ammeter, voltmeter M1730M, M1730M microammeter, milliammeter M1730M, M1730M millivoltmeter.
Output current in photoconductive devices to modify, CC and CR varies from 30mkA (no more) in a dark state to 250mkA (at least) in an illuminated state when powered from a voltage source of 10V and the lamp fixture heater voltage not exceeding 5V.
Weight devices ammeter M1730M, voltmeter M1730M, M1730M microammeter, milliammeter M1730M, M1730M millivoltmeter - 1.3 kg;
Unit dimensions with an overlay to adjust the position of filters - 160h35h270 mm.
Weight - 1.4 kg.
Dimensions staples - 182h30h230mm.
Weight - 0.3 kg.
Devices M1730M ammeter, voltmeter M1730M, M1730M microammeter, milliammeter M1730M, M1730M millivoltmeter have a flat cast aluminum alloy, closed the lid.
Measuring mechanism - the magneto system.
 

Photos M1730M

M1730M front view (scale).
M1730M front view (scale).
M1730M side view (casing depth).
M1730M side view (casing depth).
M1730M rear view (connection).
M1730M rear view (connection).


Яндекс цитирования