Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> narrow-profile DC

M1730A

17 535 RUB
7 014 UAH
available:
63 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Ammeter M1730A, M1730A voltmeter, microammeter M1730A, M1730A milliammeter, millivoltmeter M1730A (M 1730 A, M-1730-A, M1730-A, M1730 A, M 1730A, M-1730A)
 
Ammeter M1730A, M1730A voltmeter, microammeter M1730A, M1730A milliammeter, millivoltmeter M1730A designed to measure DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
Dimensions - 160h30h275mm.
Accuracy class - 1.0.
Narrow pointing.
 
Technical characteristics of the devices M1730A ammeters, voltmeters, M1730A, M1730A microammeter, milliammeter M1730A, M1730A millivoltmeters:
 
Devices with a light pointer are part of a harmonized set of analog signaling devices contact ASA.
Instruments M1730A ammeter, voltmeter M1730A, M1730A microammeter, milliammeter M1730A, M1730A millivoltmeter are used for measuring DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
The devices can be used to work in a set of transducers (sensors) SHGs.
Instruments M1730A ammeter, voltmeter M1730A, M1730A microammeter, milliammeter M1730A, M1730A millivoltmeter are designed for flush mounting on panels and boards fixed installations.
The instruments are the five modifications:
- Pointing - A;
- Signaling - C;
- Three-pin - K;
- Pin DIP with the right contact - KP;
- Pin DIP with the left contact - CR.
Instruments M1730A ammeter, voltmeter M1730A, M1730A microammeter, milliammeter M1730A, M1730A millivoltmeter used to work at ambient temperatures from -30 º C to +50 ° C and relative humidity up to 90% (at 30 ° C).
Execution of regular and tropical.
With the direct inclusion of the device ammeter M1730A, M1730A voltmeter, microammeter M1730A, M1730A milliammeter, M1730A millivoltmeter circuit in time and reassurance from 3 seconds to 4 seconds beyond measure up - 5mkA; 5mkA-0mkA-5mkA; 10mkA; 10mkA-0mkA-10mkA; 30mkA ; 30mkA-0mkA-30mkA; 50mkA.
- At the time sedation to 3 seconds beyond measure - 50mkA-0mkA-50mkA; 100mkA; 100mkA-0mkA-100mkA; 150mkA; 150mkA-0mkA-150mkA; 300mkA; 300mkA-0mkA-300mkA; 500mkA; 500mkA-0mkA-500mkA;
- At the time calm 1.5s limits of measurement - 1 mA, 1 mA, 0 mA-1 mA, 5 mA, 0 mA-5 mA-5 mA, 10 mA, 0 mA-10 mA-10 mA, 20 mA, 0 mA-20 mA to 20 mA, 30 mA, 0 mA-30 mA-30 mA , 50mA, 50mA, 50mA, 0 mA-, 100mA, 100mA 100mA, 0 mA-, 150mA, 150mA 150mA, 0 mA-, 300mA, 300mA 300mA, 0 mA-, 500mA, 500mA 500mA, 0 mA, and 1A 1A 0A 1A, 2A ; 2A-0A-2A, 5A, 5A-0A-5A.
When the device is turned ammeter M1730A, M1730A voltmeter, microammeter M1730A, M1730A milliammeter, millivoltmeter M1730A is in circuit with an external shunt 75mV at the time and calm the 1.5s are the limits of measurement - 10A, 10A-0A-10A, 20A, 20A-0A-20A , 30A, 30A-0A-30A, 50A, 50A-0A-50A, 100A, 100A-100A-0s, 150A, 150A-150A-0s, 200A, 200A-200A-0s, 300A, 300A-300A-0s; 500A , 500A-500A-0s, 750A, 750A-750A-0s and 1kA, 1kA-0kA-1kA, 2kA, 2kA-0kA-2kA, 3kA, 3kA-0kA-3kA; 4kA; 4kA-0kA-4kA; 5kA; 5kA -0kA-5kA; 6kA; 6kA-0kA-6kA.
The voltage drop across the microammeter, milliammeter and an ammeter with internal shunts less than 120mV.
An optional ammeter devices M1730A, M1730A voltmeter, microammeter M1730A, M1730A milliammeter, M1730A millivoltmeter for measuring range of 1 mA and above, and from 10 V and above may be manufactured in vertical version, as well as for mounting on panels and boards with specified when ordering a tilt angle .
At rated current 0.2 mA and 4 seconds of time calming devices measuring range ammeter M1730A, M1730A voltmeter, microammeter M1730A, M1730A milliammeter, millivoltmeter M1730A - 10 mV, 10 mV-10mV 0mV-, 20mV, 20mV, 20mV 0mV-, 45mV, 45mV, 0mV -45mV, 50mV, 50mV, 50mV 0mV-, 1B, 1B-0B-1B, 1.5 V, 1.5 V-0 V-1, 5V, 3V, 3V-0V-3V, 7.5V, 7.5V, 0V -7.5 V.
At rated current 1.0 mA and 1.5 seconds of time calming devices measuring range ammeter M1730A, M1730A voltmeter, microammeter M1730A, M1730A milliammeter, millivoltmeter M1730A - 75mV and 75mV, 75mV 0mV-.
At rated current 0.2 mA and 2.5 seconds of time calming measuring range - 100mV, 100mV, 100mV 0mV-, 200mV, 200mV, 200mV 0mV-, 500mV, 500mV, 500mV 0mV-.
At rated current 1.0 mA and 1.5 seconds of time calming devices measuring range ammeter M1730A, M1730A voltmeter, microammeter M1730A, M1730A milliammeter, millivoltmeter M1730A - 10V, 10V-0V-10V, 15V, 15V-0V-15V, 30V, 30V -0V-30V, 50V, 50V-0V-50V, 75V, 75V-0V-75V, 150V, 150V, 0V, 250V, 250V-0V-250V, 400V-0V-400V, 600V, 600V, 600V-0V-.
For microammeter with a limit of measurement 5mkA settling time is determined by external resistor is not less than 8 ohms.
The main error of the instrument ammeter M1730A, M1730A voltmeter, microammeter M1730A, M1730A milliammeter, millivoltmeter M1730A is ± 1,0%.
Burst Tolerance photocontact device of the instrument is ± 1,5%.
Operating position of ammeter instrumentation M1730A, M1730A voltmeter, microammeter M1730A, M1730A milliammeter, millivoltmeter M1730A - horizontal.
The length scale devices - 120mm.
Change the ammeter readings of M1730A, M1730A voltmeter, microammeter M1730A, M1730A milliammeter, millivoltmeter M1730A caused by ambient temperature deviation from the normal (ranging from -30 º C to +50 ° C) for every 10 degrees less than ± 0,8% for instruments accuracy class 1.0 and ± 0,4% - for instruments of accuracy class 0.5;
- Under the influence of external magnetic field strength of 400 A / m - not more than ± 0,5%; rejecting the instrument at 5 ° in any direction from the working position - does not exceed ± 1,0% for instruments M1730A ammeter, voltmeter M1730A, M1730A microammeter, milliammeter M1730A, M1730A millivoltmeter.
Output current in photoconductive devices to modify, CC and CR varies from 30mkA (no more) in a dark state to 250mkA (at least) in the illuminated state when powered from a voltage source of 10V and heater voltage lamp fixture no more than 5V.
Weight devices ammeter M1730A, M1730A voltmeter, microammeter M1730A, M1730A milliammeter, millivoltmeter M1730A - 1.3 kg;
Unit dimensions with cover to the adjustment of filters - mm 160h35h270.
Weight - 1.4 kg.
Dimensions staples - 182h30h230mm.
Weight - 0.3 kg.
Instruments M1730A ammeter, voltmeter M1730A, M1730A microammeter, milliammeter M1730A, M1730A millivoltmeter have a flat cast aluminum alloy, closed the lid.
The measuring mechanism - the magneto system.
 

Photos M1730A

M1730A front view (scale).
M1730A front view (scale).
M1730A side view (casing depth).
M1730A side view (casing depth).
M1730A rear view (connection).
M1730A rear view (connection).


Яндекс цитирования