Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> narrow-profile DC

M1730

17 535 RUB
7 014 UAH
available:
55 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
M1730 ammeter, voltmeter M1730, M1730 microammeter, milliammeter M1730, M1730 millivoltmeter (M 1730, M-1730)
 
M1730 ammeter, voltmeter M1730, M1730 microammeter, milliammeter M1730, M1730 millivoltmeter designed to measure DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
Dimensions - 160h30h275mm.
Accuracy Class - 1.0.
Narrow.
 
Specifications M1730 devices ammeters, voltmeters, M1730, M1730 microammeter, milliammeter M1730, M1730 millivoltmeters:
 
Devices with a light indicator are part of a harmonized set of analog to signal pin devices ASA.
Devices M1730 ammeter, voltmeter M1730, M1730 microammeter, milliammeter M1730, M1730 millivoltmeter used to measure DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
The devices can be used to work in a set of transducers (sensors) SHGs.
Devices M1730 ammeter, voltmeter M1730, M1730 microammeter, milliammeter M1730, M1730 millivoltmeter designed for flush mounting on panels and stationary billboards.
The instruments are the five modifications:
- Pointing - A;
- Signaling - C;
- Three-pin - K;
- Pin DIP with the right contact - KP;
- Pin DIP with the left contact - CR.
Devices M1730 ammeter, voltmeter M1730, M1730 microammeter, milliammeter M1730, M1730 millivoltmeter used to work at an ambient temperature of -30 º C to +50 ° C and relative humidity to 90% (at 30 ° C).
Execution of regular and tropical.
When the device is turned directly M1730 ammeter, voltmeter M1730, M1730 microammeter, milliammeter M1730, M1730 millivoltmeter chain in time and reassurance from 3 seconds to 4 seconds beyond measure up - 5mkA; 5mkA-0mkA-5mkA; 10mkA; 10mkA-0mkA-10mkA; 30mkA ; 30mkA-0mkA-30mkA; 50mkA.
- At time calm to 3 seconds beyond measure - 50mkA-0mkA-50mkA; 100mkA; 100mkA-0mkA-100mkA; 150mkA; 150mkA-0mkA-150mkA; 300mkA; 300mkA-0mkA-300mkA; 500mkA; 500mkA-0mkA-500mkA;
- At time calm the limits of measurement 1.5 seconds - 1 mA, 0 mA-1mA 1mA-, 5 mA, 0 mA-5mA 5mA-, 10mA, 10mA, 0 mA-10 mA, 20mA, 20mA, 0 mA to 20mA, 30mA, 30mA, 0 mA-30 mA , 50mA; 50mA-50mA-0 mA, 100mA, 100mA, 100mA, 0 mA, 150mA, 150mA, 150mA, 0 mA, 300 mA, 300 mA 0 mA-300 mA-, 500mA, 500mA, 500mA and 0 mA-1A, 1A-0A-1A, 2A , 2A-0A-2A, 5A, 5A-0A-5A.
When the device is turned M1730 ammeter, voltmeter M1730, M1730 microammeter, milliammeter M1730, M1730 millivoltmeter in circuit with an external shunt to 75mV and 1.5 seconds of time calming measurement limits are - 10A, 10A-0A-10A, 20A, 20A-0A-20A , 30A, 30A-0A-30A, 50A, 50A-0A-50A, 100A, 100A-100A-0s, 150A, 150A-150A-0s, 200A, 200A-200A-0s, 300A, 300A-300A-0s; 500A , 500A-500A-0s, 750A, 750A-750A-0s and 1kA, 1kA-0kA-1kA, 2kA, 2kA-0kA-2kA, 3kA, 3kA-0kA-3kA; 4kA; 4kA-0kA-4kA; 5kA; 5kA -0kA-5kA, 6kA, 6kA, 0kA-6kA.
The voltage drop across microammeter, milliammeter and ammeter with internal shunts less than 120mV.
An optional ammeter instruments M1730, M1730 voltmeter, microammeter M1730, M1730 milliammeter, millivoltmeter M1730 on the limits of measurement from 1mA above 10V and from above and can be manufactured in vertical version, as well as for installation in panels and boards with specified when ordering angle .
At rated current 0.2 mA and 4 seconds of time calming devices measuring range ammeter M1730, M1730 voltmeter, microammeter M1730, M1730 milliammeter, millivoltmeter M1730 - 10 mV, 10 mV 0mV-10mV-, 20mV, 20mV, 20mV 0mV-, 45mV, 45mV, 0mV -45mV, 50mV, 50mV, 50mV 0mV-, 1B, 1B-0V-1V, 1.5 V, 1.5 V-0 V-1, 5V, 3V, 3V, 0V, 3V, 7.5 V, 7.5 V-0V -7.5 V.
At rated current 1.0 mA and 1.5 sec time calming devices measuring range ammeter M1730, M1730 voltmeter, microammeter M1730, M1730 milliammeter, millivoltmeter M1730 - 75mV and 75mV-75mV-0mV.
At rated current 0.2 mA and 2.5 seconds of time calming the limits of measurement - 100mV, 100mV, 0mV-100mV, 200mV, 200mV, 0mV-200mV, 500mV, 500mV, 0mV-500mV.
At rated current 1.0 mA and 1.5 sec time calming devices measuring range ammeter M1730, M1730 voltmeter, microammeter M1730, M1730 milliammeter, millivoltmeter M1730 - 10V, 10V-0V-10V, 15V, 15V-0V-15V, 30V, 30V -0V-30V, 50V, 50V-0V-50V, 75V, 75V-0V-75V, 150V-150V-0V, 250V, 250V-0V-250V, 400V-0V-400V, 600V, 600V-600V-0V.
To limit measurements with microammeter 5mkA settling time is determined by the external resistance is not less than 8 ohms.
The main error of the instrument M1730 ammeter, voltmeter M1730, M1730 microammeter, milliammeter M1730, M1730 millivoltmeter is ± 1,0%.
Burst Tolerance photocontact device of the instrument is ± 1,5%.
Operating position of ammeter instrumentation M1730, M1730 voltmeter, microammeter M1730, M1730 milliammeter, millivoltmeter M1730 - horizontal.
The length scale devices - 120mm.
Change the readings of ammeter M1730, M1730 voltmeter, microammeter M1730, M1730 milliammeter, millivoltmeter M1730 caused a deviation of ambient temperature from normal (ranging from -30 º C to +50 ° C) for every 10 degrees less than ± 0,8% for instruments accuracy class 1,0 and ± 0,4% - for instruments of accuracy class 0.5;
- Under the influence of external magnetic field strength of 400 A / m - not more than ± 0,5%; rejecting device at 5 ° in any direction from the working position - does not exceed ± 1,0% for instruments M1730 ammeter, voltmeter M1730, M1730 microammeter, milliammeter M1730, M1730 millivoltmeter.
Output current in photoconductive devices to modify, CC and CR varies from 30mkA (no more) in a dark state to 250mkA (at least) in an illuminated state when powered from a voltage source of 10V and the lamp fixture heater voltage not exceeding 5V.
Weight M1730 devices ammeter, voltmeter M1730, M1730 microammeter, milliammeter M1730, M1730 millivoltmeter - 1.3 kg;
Unit dimensions with an overlay to adjust the position of filters - 160h35h270 mm.
Weight - 1.4 kg.
Dimensions staples - 182h30h230mm.
Weight - 0.3 kg.
Devices M1730 ammeter, voltmeter M1730, M1730 microammeter, milliammeter M1730, M1730 millivoltmeter have a flat cast aluminum alloy housing, closed the lid.
Measuring mechanism - the magneto system.
 

Photos M1730

M1730 front view (scale).
M1730 front view (scale).
M1730 side view (casing depth).
M1730 side view (casing depth).
M1730 rear view (connection).
M1730 rear view (connection).


Яндекс цитирования