Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> narrow-profile DC

M1632-M1

17 465 RUB
4 657 UAH
available:
72 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Ammeter M1632-M1 microammeter M1632-M1 (M 1632 M1, M-1632-M1, M1632- M1, M1632 M1, M-1632M1, M 1632M1)
 
Ammeter M1632-M1, M1632-M1 microammeter designed to measure DC and other electrical, magnetic and non-electrical quantities, if they are normalized values ​​of testimony in terms of current, as well as for signaling on the measured value of the nominal values ​​of the area and built a radio-measuring equipment .
Dimensions - 120h30h180mm.
Accuracy Class - 1.0.
Narrow.
 
Technical characteristics of the devices ammeters M1632-M1, M1632-M1 microammeter:
 
Ammeter M1632-M1, M1632-M1 microammeter narrow-profile used to work at an ambient temperature of -30 º C to +50 ° C and a relative humidity of 90% (at 30 o C).
Devices manufactured in tropical version, designed for operation at ambient temperatures from 0 º C to 60 ° C and relative humidity of 98%.
Resistance to mechanical impact devices ammeter M1632-M1, M1632-M1 microammeter are common.
Measuring range: 5mkA-0mkA5mkA; 10mkA-0mkA-10mkA; 25mkA-0mkA-25mkA; 50mkA-0mkA-50mkA and 100mkA.
Accuracy class instruments - 1.0.
Burst Tolerance photosensitive elements ammeter instruments M1632-M1, M1632-M1 microammeter not exceed ± 2%.
Output current varies from photoconductive 30mkA (no more) in a dark state to 250mkA (at least) in an illuminated state when powered from a voltage source of 10V and the lamp fixture heater voltage not exceeding 5V.
The voltage drop across the ammeter instruments M1632-M1, M1632-M1 microammeter less than 60mV.
Dining lamp fixture made from any source of AC voltage 5.0 V.
This voltage must not exceed ± 10%.
Photosensitive elements of the devices ammeter M1632-M1, M1632-M1 microammeter provide activate the alarm device at the approach of a light pointer to point to the left to the right scale, corresponding to 33%, and at the approach of left-to-point scale, corresponding to 103% of the total current deviation.
In devices with double the scale of operation occurs at the approach of a light pointer to point scale, corresponding to 103% of the total current deviation.
Settling time of less than 4 seconds.
Ammeters, microammeter Narrow M1632-M1 has one or two scales.
Change the ammeter readings M1632-M1, M1632-M1 microammeter caused by the deviation of the ambient temperature from normal, does not exceed ± 0,8% for every 10 deg, when the instrument is in a ferromagnetic shield 3mm thick - less than ± 0,5% final scale value (and for devices with two-sided scale - the amount of full scale value).
Weight - no more than 0.7 kg.
Gauges Ammeter M1632-M1, M1632-M1 microammeter have a flat cast aluminum alloy housing, closed the lid.Inside the case are available magnetoelectric measuring mechanism with vnutriramochnym magnet, with a movable part, locked in internal eplennoy banners.
 

Photos M1632-M1

M1632-M1 front view (scale).
M1632-M1 front view (scale).
M1632-M1 side view (casing depth).
M1632-M1 side view (casing depth).
M1632-M1 rear view (connection).