Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> narrow-profile DC

M1531A

15 878 RUB
4 234 UAH
available:
47 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
M1531A ammeter, voltmeter M1531A, M1531A microammeter, milliammeter M1531A, M1531A millivoltmeter (M 1531 A, M-1531-A , M1531-A, M1531 A, M 1531A, M-1531A)
 
M1531A ammeter, voltmeter M1531A, M1531A microammeter, milliammeter M1531A, M1531A millivoltmeter is designed to measure DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
Dimensions - 100h30h227mm.
Accuracy Class - 1.0.
Narrow.
 
Technical characteristics of the devices M1531A voltmeters, ammeters M1531A, M1531A milliammeter, millivoltmeters M1531A, M1531A microammeter:
 
Devices with a light indicator designed to measure DC voltage and current, as well as other electrical, magnetic and non-electrical quantities, if these units are normalized to the value of their testimony in terms of current or voltage.
Instruments M1531A ammeter, voltmeter M1531A, M1531A microammeter, milliammeter M1531A, M1531A millivoltmeter used to work in a set of transducers (sensors) SHGs.
Devices used for ambient temperatures from -30 º C to +50 ° C and relative humidity to 90% (at 30 ° C).
Devices manufactured in tropical version, designed for operation at ambient temperatures from -10 º C to +35 ° C and a relative humidity of 95%.
In terms of resistance to mechanical stress during operation devices M1531A ammeter, voltmeter M1531A, M1531A microammeter, milliammeter M1531A, M1531A millivoltmeter are common.
When the device is turned directly into the circuit and time calming 4 sec measurement limits are as follows: 0mkA-5mkA; 5mkA-0mkA-5mkA; 0mkA-40mkA; 10mkA-0mkA-10mkA; 0mkA-30mkA; 30mkA-0mkA-30mkA and 50mkA;
- At time calm 3s limits of measurement - 50mkA-0mkA-50mkA; 0mkA-100mkA; 100mkA-0mkA-100mkA; 0mkA-150mkA; 150mkA-0mkA-150mkA; 0mkA-300mkA; 300mkA-0mkA 300mkA-and-0mkA 500mkA;
- At time calm 1.5s beyond measure - 500mkA-0mkA-500mkA, 0 mA-1mA, 0 mA-1mA 1mA-, 0 mA-5mA, 0 mA-5mA 5mA-, 0 mA-10 mA, 0 mA-10mA-10mA; 0 mA to 20 mA , 0 mA-20mA-20mA; 0 mA-30 mA, 0 mA-30mA-30mA; 0 mA, 50mA, 50mA, 50mA, 0 mA-, 0 mA-100mA, 100mA, 100mA, 0 mA, 0 mA-150mA, 150mA, 150mA, 0 mA, 0 mA-300 mA , 0 mA-300mA-300mA; 0 mA-500mA, 500mA, 500mA, 0 mA; 0A-1A, 1A-0A-1A 0A-2A, 2A-0A-2A, 0A-5A, 5A-0A-5A.
When the device is turned M1531A ammeter, voltmeter M1531A, M1531A microammeter, milliammeter M1531A, M1531A millivoltmeter with external shunt 75mV and 45mV at time calm and 1.5s measurement limits are as follows: 0A-10A, 10A-0A-10A; 0A-20A, 20A -0A-20A; 0A-30A, 30A-0A-30A; 0A-50A, 50A-0A-50A; 0A-100A, 100A-100A-0s, 0s-150A, 150A-150A-0s, 0s-200A, 900A -0A-200A, 300A-0s, 0s-300A-300A; 0A-500A, 500A-500A-0s, 0s-750A, 750A-750A-0s; 0kA-1kA; 1kA-0kA-1kA; 0kA-2kA; 2kA -0kA-2kA; 0kA-3kA; 3kA-0kA-3kA; 0kA-4kA; 4kA-0kA-4kA; 0kA-5kA; 5kA-0kA-5kA; 0kA-6kA, 6kA, 0kA-6kA.
At the rated current of 0.2 mA and the circuit damping time 4 seconds, the range of variation M1531A device ammeter, voltmeter M1531A, M1531A microammeter, milliammeter M1531A, M1531A millivoltmeter - 0mV-10mV, 10mV, 10mV 0mV-; 0mV-20mV, 20mV, 20mV 0mV- , 0mV-45mV, 45mV, 45mV 0mV-; 0mV-50mV, 50mV, 50mV 0mV-; 0mV-100mV, 100mV, 100mV, 0mV, 0mV-200mV, 200mV, 200mV, 0mV, 0mV-500mV, 500mV, 500mV, 0mV , 0V-1V, 0V-1V-1V, 0V-1, 5V, 1.5 V-0 V-1, 5V, 0V-3V; 3B-0B-3B; 0V-7, 5 V and 7.5 V-0 V-7 5V.
At the rated current of 1.0 mA and the circuit damping time 1.5 seconds, the limits of measurement devices M1531A ammeter, voltmeter M1531A, M1531A microammeter, milliammeter M1531A, M1531A millivoltmeter - 0mV-75mV, 75mV, 75mV 0mV-, 0V-10V, 10V, 0V -10V, 0V-15V, 15V-0V-15V, 0V-30V, 30V-0V-30V, 0V-50V, 50V-0V-50V, 0V-75V, 75V-0V-75V, 0V-150V, 150V, 0V -150V, 0V-250V, 250V-0V-250V, 0V-400V, 400V-0V-400V, 0V-600V and 600V-600V-0V.
Rated current and voltmeters millivoltmeter different from the values ​​listed above, no more than ± 20%.
The voltage drop in circuits microammeter, milliammeter and ammeters not exceed 120mV.
The length scale devices M1531A ammeter, voltmeter M1531A, M1531A microammeter, milliammeter M1531A, M1531A millivoltmeter - 65mm.
Devices are available in horizontal version.
Change the readings due to ambient temperature deviation from normal is less than ± 0,8% for every 10 deg, the influence of external magnetic field strength of 400 A / m - not more than ± 0,6%.
Overall dimensions M1531A ammeter, voltmeter M1531A, M1531A microammeter, milliammeter M1531A, M1531A millivoltmeter - 100h30h227mm;
Unit weight - no more than 0.75 kg.
Devices have a flat cast aluminum alloy housing, the lid closed. Inside the case are available magnetoelectric measuring mechanism with vnutriramochnym magnet, with a movable part fixed to the internal braces, the optical system and elements of the measuring system.
M1531A device ammeter, voltmeter M1531A, M1531A microammeter, milliammeter M1531A, M1531A millivoltmeter has bezparallaksny count.
On the cover of the device removed proofreader and regulators set of filters.
The scale of the instrument is equipped with a slot closed by a matte screen, which projected a light pointer.
Connect the device M1531A ammeter, voltmeter M1531A, M1531A microammeter, milliammeter M1531A, M1531A millivoltmeter to the measured circuit is carried out by means of soldering according to the scheme applied to the lid of the device.
 