Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> size 60x60mm

M1001M

2 283 RUB
609 UAH
available:
1 226 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
M1001M ammeter, voltmeter M1001M, M1001M microammeter, milliammeter M1001M, M1001M millivoltmeter, ampervoltmetr M1001M (M 1001 M, M-1001-M, M-1001M, M1001-M, M 1001M, M1001 M)
 
M1001M ammeter, voltmeter M1001M, M1001M microammeter, milliammeter M1001M, M1001M millivoltmeter, ampervoltmetr M1001M designed to measure DC voltage and current in various branches of industrial production.
Dimensions - no more 60h60h48mm.
Accuracy Class - 1.5 and 2.5.
 
Technical characteristics of the devices M1001M ammeters, voltmeters, M1001M, M1001M microammeter, milliammeter M1001M, M1001M millivoltmeters, ampervoltmetry M1001M:
 
According to the principle of the devices are magnetoelectric, which are based on the interaction of the magnetic field of a permanent magnet with an electric current passing along the winding frame unit.
Gauges are small-sized panel ammeters, milliammeter microammeter and voltmeters.
Measuring mechanism is made to mount the magnet and vnutriramochnym moving parts on the cores or braces, with needle indicator.
Scale devices M1001M ammeter, voltmeter M1001M, M1001M microammeter, milliammeter M1001M, M1001M millivoltmeter, ampervoltmetr M1001M - unilateral, bilateral, symmetrical, uniform, with a working part, covering the entire length of the scale.
The units have a proofreader for the establishment of the arrow mark on the mechanical zero.
Devices M1001M ammeter, voltmeter M1001M, M1001M microammeter, milliammeter M1001M, M1001M millivoltmeter, ampervoltmetr M1001M structurally designed in plastic enclosure with a square flange and cylindrical portion for flush mounting.Corps units are protected from damage and contamination.
Accuracy class instruments - 1.5 and 2.5.
The final value of single-and double-sided scale devices M1001M ammeter, voltmeter M1001M, M1001M microammeter, milliammeter M1001M, M1001M millivoltmeter, ampervoltmetr M1001M:
- Odnopredelnyh microammeter - 50mkA; 100mkA; 200mkA; 300mkA; 500mkA; 1000mkA;
- Odnopredelnyh milliammeter - 1mA, 5mA, 10mA, 15mA, 30mA, 50mA, 100mA, 150mA, 300mA, 500mA, 600mA;
- Dvuhpredelnyh milliammeter - 3/30mA, 3/50mA, 5/50mA;
- Odnopredelnyh ammeters - 1A, 2A, 3A, 5A, 10A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 500A, 750A, 1000A, 2000A, 4000A, 6000A, 7500A;
- Odnopredelnyh millivoltmeter - 25mV, 50mV, 75mV, 150mV, 300mV, 500mV, 750mV, 1000mV;
- Odnopredelnyh voltmeters - 1.5; 2B 3B, 7.5 V, 10V, 15V, 30V, 50V, 75V, 100V, 150V, 250V, 300V, 450V, 500V, 600V, 1000V, 1500V, 3000V;
- Dvuhpredelnyh voltmeters - 3/30V, 30/300V, 7.5 / 300V, 10/100V, 15/150V, 15/300V, 0.3 / 15V;
- Ampervoltmetrov - 1/3000A/V; 30/50V/A; 15/500V/mA; 50/50V/A.
Limit the permissible basic error M1001M devices ammeter, voltmeter M1001M, M1001M microammeter, milliammeter M1001M, M1001M millivoltmeter, ampervoltmetr M1001M no more than ± 1,5% for accuracy class 1,5 and ± 2,5% for accuracy class 2.5.
Permissible limit of variation of 1.5% for accuracy class 1.5 and 2.5% for accuracy class 2.5.
The residual deviation of the index from zero up to 0.66 mm for the accuracy class of 1.5 mm and 1.1 mm for accuracy class 2.5.
The limit of permissible additional error M1001M devices ammeter, voltmeter M1001M, M1001M microammeter, milliammeter M1001M, M1001M millivoltmeter, ampervoltmetr M1001M from the influence of an external magnetic field with induction 0.5 mT no more than ± 1,5% for accuracy class 1.5 and 2.5.
The limit of permissible additional error from the influence of the ferromagnetic shield 2 mm ± 0,5 mm ± 0,75% for accuracy class 1.5 and ± 1,25% for accuracy class 2.5.
The limit of permissible additional error from the influence of inclination of 45 ° from the operating position in any direction ± 1,5% for accuracy class 1,5 and ± 2,5% for accuracy class 2.5.
The limit of permissible additional error from temperature changes from normal to anyone within the working temperature for every 10 ° C ± 0,75% for accuracy class 1.5 and ± 1,25% for accuracy class 2.5.
The limit of permissible additional error caused by exposure to high humidity in the working conditions of application, ± 1,5% for accuracy class 1,5 and ± 2,5% for accuracy class 2.5.
Response time devices M1001M ammeter, voltmeter M1001M, M1001M microammeter, milliammeter M1001M, M1001M millivoltmeter, ampervoltmetr M1001M not exceed 3s.
Isolation between the body and insulated from the hull of the DC electric circuits unit shall withstand for 1 minute action of the test voltage ac, 50 Hz, the current value is to be:
- 2kV at an ambient temperature of 20 º C ± 5 ° C and a relative humidity of 30% ... 80%;
-1.2 KV at an ambient temperature of 35 ° C and relative humidity of 95%.
Insulation resistance ammeter instruments M1001M, M1001M voltmeter, microammeter M1001M, M1001M milliammeter, millivoltmeter M1001M, M1001M ampervoltmetr between the housing and insulated DC electric circuits device at an operating voltage up to 500V:
- 40 ohms at 20 º C ± 5 ° C and relative humidity 30% ... 80%;
- 5 ohms at 60 ° C and relative humidity to 80%;
- 2 ohms at 20 º C ± 5 ° C and relative humidity of 95%.
Dimensions not exceeding 60h60h48mm.
Weight devices M1001M ammeter, voltmeter M1001M, M1001M microammeter, milliammeter M1001M, M1001M millivoltmeter, ampervoltmetr M1001M - no more than 0.12 kg.
Devices are nonrecoverable products.
MTBF 65,000 hours The average lifetime of 10 years.
Operation of devices M1001M ammeter, voltmeter M1001M, M1001M microammeter, milliammeter M1001M, M1001M millivoltmeter, ampervoltmetr M1001M: ambient temperature -50 º C ...+60 ° C, relative humidity 95% at 35 ° C.

Photos M1001M

M1001M front view (scale).
M1001M front view (scale).
M1001M side view (casing depth).
M1001M side view (casing depth).
M1001M rear view (connection).
M1001M rear view (connection).


Яндекс цитирования