Electrical measuring instruments >> measuring transducers >> transducers E

E848-М1 (Е848-М1)

14 879 RUB
4 960 UAH
available:
27 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Measuring active power converter phase current E848-M1 (e-848-m1, e 848 m1, e-848m1, e 848m1, e848 m1)
 
Designed for a linear transformation of the active power of three-and single-phase, four-and three-wire AC circuits into a unified output signal of direct current or DC voltage. 
 
Converters measuring active power three-phase current E848-M1 designed for a linear transformation of the active power of three-and single-phase, four-and three-wire AC circuits into a unified output signal of direct current or DC voltage.
 
Information is the mean value of the output signal.
Measuring active power converter phase current E848-M1 is used to control power electrical networks and installations for complex automation of electric power facilities, power-control system objects.
E848-M1 transducer measuring active power three-phase current is available in packages intended for surface mounting on boards and panels off either directly or through measuring current and voltage transformers.
 
Main technical data converters are shown in Table
Modifi-cation
of IP
Measurement range of the transformed input The range of the output signal Power Options
current, A voltage, V power factor current, mA voltage, V
E848/1-M1 0A-1A (0A-0, 5A) ili0A-5A (0A-2, 5A) 80V-120V 0-plus 1-0 0 mA-5 mA - from the measuring circuit
E848/2-M1 0A-1A (0A-0, 5A) ili0A-5A (0A-2, 5A) 80V-120V 0-minus 1-0 plus 1-0 minus-5mA 5mA 0 mA-plus - from the measuring circuit
E848/3-M1 0A-1A (0A-0, 5A) ili0A-5A (0A-2, 5A) 0V-120V 0-plus 1-0 0 mA-5 mA - 220V 45Hz, 65Hz
E848/4-M1 0A-1A (0A-0, 5A) ili0A-5A (0A-2, 5A) 0V-120V 0-minus 1-0 plus 1-0 minus-5mA 5mA 0 mA-plus - 220V 45Hz, 65Hz
E848/5-M1 0A-1A (0A-0, 5A) ili0A-5A (0A-2, 5A) 80V-120V 0-plus 1-0 4mA to 20mA - from the measuring circuit
E848/6-M1 0A-1A (0A-0, 5A) ili0A-5A (0A-2, 5A) 0V-60V 0V-120V 0V-250V- 450V 0V 0-minus 1-0 plus 1-0 minus-5mA 0 mA-
- Plus 5mA
- 220V 45Hz, 65Hz
E848/7-M1 0A-1A (0A-0, 5A) ili0A-5A (0A-2, 5A) 0V-60V 0V-120V 0-minus 1-0 plus 1-0 - minus 10-0-10 plus 220V 45Hz, 65Hz
E848/8-M1 0A-1A (0A-0, 5A) ili0A-5A (0A-2, 5A) 80V-120V 0-plus 1-0 0 mA-5 mA - from the measuring circuit
E848/9-M1 0A-1A (0A-0, 5A) ili0A-5A (0A-2, 5A) 0V-120V 0-plus 1-0 0 mA-5 mA - 220V 45Hz, 65Hz
E848/10-M1 0A-1A (0A-0, 5A) ili0A-5A (0A-2, 5A) 80V-120V 0-minus 1-0 plus 1-0 minus 5mA 5mA-0mA plyus - from the measuring circuit
E848/11-M1 0A-1A (0A-0, 5A) ili0A-5A (0A-2, 5A) 0V-120V 0-minus 1-0
0 plus 1-0
minus 5mA 5mA-0mA plyus - 220V 45Hz, 65Hz
E848/12-M1 0A-1A (0A-0, 5A) ili0A-5A (0A-2, 5A) 0V-120V 0 + 1 -0 0 mA-2, 5 mA, 5, 0 mA - 220V 45-65Hz
E848/13-M1 0A-1A (0A-0, 5A) ili0A-5A (0A-2, 5A) 80V-120V 0-plus 1-0 4mA to 20mA - from the measuring circuit
 
Limits of the reduced basic error,% 0
Power consumption, V · A
0.3 · A - for each series circuit of phase A, B or C
0.2 · A - for a parallel circuit of phase B
not more than 6,0 V · A - for the parallel chains of phase A or C
Overall dimensions, mm 125h110h125mm
Weight, kg 1.2 kg

Photos: E848-М1 (Е848-М1)

E848/13-M1 (Е848/13-М1) transducer image.
E848/13-M1 (Е848/13-М1) transducer image.
E848/13-M1 (Е848/13-М1) front view.
E848/13-M1 (Е848/13-М1) front view.
E848/13-M1 (Е848/13-М1) side view.
E848/13-M1 (Е848/13-М1) side view.
E848/13-M1 (Е848/13-М1) rear view.
E848/13-M1 (Е848/13-М1) rear view.
E848/13-M1 (Е848/13-М1) side view.
E848/13-M1 (Е848/13-М1) side view.


Яндекс цитирования