Radiometric devices >> RLC meters

E7-13

33 999 RUB
13 600 UAH
available:
4 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
RLC meter E7-13 (E713, E-7-13, E 7 13, E7 13)
 
RLC meter E7-13 is designed to measure capacitance, inductance and resistance of the alternating current, as well as the parameters of the complex impedance of capacitive and inductive nature in a wide range of measurement of phase angle.
 
Technical characteristics of the instrument gauges RLC E7-13:
 
The functionality of the device can be enhanced through the use of sensors that convert physical quantity measured in the capacitance, inductance, resistance (measuring temperature, pressure, linear and angular dimensions, humidity, etc.).
The instrument meter E7-13 RLC can be used in the manufacture, repair and maintenance of electronic equipment, electrical control and radio components, and in conjunction with sensors - in different areas of the economy.
Operation is a common channel (CPC) and an automated measuring system (AIS) is not provided.
Capacity - 0.1 pF to 10mkF;
Inductance - from 1mkGn to 100 Gn;
Conductance - from 10nSm to 100mSm;
Active resistance - from 0.01 ohms to 1 Mohm;
Complex impedance capacitive measuring device E7-13 RLC in parallel displacement (capacitance and conductance) - from 1pF to 10mkF parallel impedance of 10 ohms to 10 megohms;
Complex impedance inductive nature of the serial equivalent circuit (inductance and resistance) - from 1 Hz to 100mkGts with series resistance of 1 ohm to 100 ohms;
The operating frequency of the instrument meter E7-13 RLC, in which the measurements are equal to 1000 Hz ± 10 Hz and has a sinusoidal form.
The ambient air temperature - from 263K to 323K (from -10 º C to +50 ° C);
Relative humidity up to 96% at a temperature of 298K (25 ° C);
Atmospheric pressure - from 84kPa to 106kPa;
Power supply RLC meter E7-13 is carried out:
- AC 220V +22 V, 50 Hz 0.5 Hz, with harmonic content up to 5% or 115V voltage 5.75 V, 220 V 11 V, frequency 400 Hz 10 Hz power supply connected to the network;
- From five series-connected batteries SAG-1 ,5-V1 .1 or two elements ZZZ6U to connect the power supply battery.
The power consumed by the device - no more than:
- When on AC power - 5V ∙ A;
- When on battery power - 1.5 watts (when supply voltage from 5.6 V to 10 V).
Weight of the device meter E7-13 RLC - no more than 2kg.
Weight of the device in the package - 11kg.
The manufacturer guarantees the quality of the instrument meter E7-13 RLC technical requirements specifications subject to user terms and conditions of storage, transportation, installation, operation, established specifications and operational documentation.

Photos: E7-13

E7-13 meter image.
E7-13 meter image.
E7-13 front view.
E7-13 front view.
E7-13 side view.
E7-13 side view.
E7-13 rear view.
E7-13 rear view.
E7-13 side view.
E7-13 side view.
E7-13 overhead view.
E7-13 overhead view.
E7-13 bottom view.
E7-13 bottom view.