Radiometric devices >> RLC meters

E7-11

9 999 RUB
7 999 UAH
available:
11 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

RLC measuringE7-11 (E711, E7 11, e7-11, e711, e7 11)

Measures the inductance, capacitance, dissipation factor, quality factor of various elements of radio devices.
Range:
capacitance (C) 0.5-pF 1000uF;
Inductance (L) 0,3 uH - 1000Gn;
Resistance (R) 0,1 ohm-10M;
conductance (G) 0,1 nS - 1 cm,
loss tangent (tgδ) 0,003-0,1
quality factor (Q) 0,1-30

UniversalRLC measuringE7-11 provides measurement of inductance, capacitance, dissipation factor, quality factor of various elements of the wireless devices. Along with the basic features may determine the capacitance of nonlinear elements (varactors, diodes, Zener diodes, and so on).
Enhancing the functionality of the device universal measuring E7-11 achieved by supplying the measured object polarizing voltage to 30 V, and the bias current up to 30 mA from an external source. The measuring principle is based on the bridged method. The countdown of the measurements performed on the scale indicating devices when the balance arm of the bridge.

UniversalRLC measuringE7-11
The range of measurements universalRLC measuring E7-11:
capacitance (C) of 0.5 pF-1000 uF;
Inductance (L) 0,3 uH - 1000Gn;
Resistance (R) 0,1 ohm-10M;
conductance (G) 0,1 nS - 1 cm,
loss tangent (tgδ) 0,003-0,1
quality factor (Q) 0,1-30

Measurement error:
Capacity ± (0,01 C + 0.2 pF) (0.5 pF to 10 mF), ± 0,02 C (10-1000 uF);
inductance ± (0,02 L +0,1 uH) (uH 0.3-100), ± 0,01 L (100 uH-10 H), ± 0,02 L (10-100 H);
Resistance ± (0,02 R + 0,05 ohms) (ohms -10 0.1), ± (0,01 R + 0,05 Ohm) (10 ohm-1 MOhm), ± 0,02 R (1 - 10 MW);
Dissipation factor ± (0.1 tgδ + 5-3)
Q ± (10 + 0,5 Q)%

Measuring frequency 1000 Hz 100, DC.
 
UniversalRLC measuring E7-11 bespechivaet about the possibility of measuring containers of non-linear elements. Provides a measurement of inductance, capacitance, dissipation factor, quality factor of various elements of the wireless devices. Along with the basic measurements can determine the capacitance of non-linear elements (varactors, diodes, zener diodes, etc.).
Enhancing the functionality of the device universalRLC measuringE7-11 achieved by supplying the measured object polarizing voltage to 30 V, and the bias current up to 30 mA from an external source.
The principle of the measurement device E7-11 is bridged method. The countdown of the measurements performed on the scale indicating devices when the balance arm of the bridge.
 
Basic data E7-11
 
Range:
capacitance (C) 0.5 pF-1000 uF
inductance (L) 0.3 m to Gn - 1000 GN
Resistance (R) 0.1 Ohm-10M
conductance (G) 0.1 nS - 1 D
loss tangent (tgδ) 0.003-0.1
quality factor (Q) 0.1-30
Measurement error:
capacity ± (0,01 C + 0.2 pF) (0.5 pF to 10 mF), ± 0,02 C (10-1000 uF)
Inductance ± (0,02 L +0,1 uH) (uH 0.3-100), ± 0,01 L (100 mg, 10 H), ± 0,02 L (10-100 H)
Resistance ± (0,02 R + 0,05 ohms) (ohms -10 0.1), ± (0,01 R + 0,05 Ohm) (10 ohm-1 MOhm), ± 0,02 R (1 - 10 M )
loss tangent ± (0.1 tgδ + 5-3)
Q ± (10 + 0,5 Q)%
Power supply: 220 V, 50 Hz and 400.
Power consumption 10 V · A.
Dimensions 342X173X332 mm.
9 kg.

Photos: E7-11

E7-11 measuring image.
E7-11 measuring image.
E7-11 front view.
E7-11 front view.
E7-11 side view.
E7-11 side view.
E7-11 rear view.
E7-11 rear view.
E7-11 side view.
E7-11 side view.
E7-11 overhead view.
E7-11 overhead view.
E7-11 bottom view.
E7-11 bottom view.


Яндекс цитирования