E514 portable ammeter

Also, this device can be called: E-514, E 514.

E514 is a portable ammeter device electromagnetic system and is designed to measure the strength of AC and DC.

Ammeters E514 made ​​the following modifications:

Modification The final value of the measuring range Rated frequency range Extended frequency range
E514 / 1 1 A; 2A from 40 Hz to 100 Hz from 100 Hz to 2000 Hz
E514 / 2 2,5 A; 5 A from 40 Hz to 60 Hz from 60 Hz to 1500 Hz
E514 / 3 5 A; 10 A

from 40 Hz to 60 Hz;

from 40 Hz to 100 Hz

from 100 Hz to 2000 Hz;

from 60 Hz to 1500 Hz

E514 / 4 2,5 A; 5 A from 40 Hz to 1500 Hz from 1500 Hz to 3000 Hz
E514 / 5 5 A; 10 A from 40 Hz to 1500 Hz from 1500 Hz to 3000 Hz

Specifications E514:

Accuracy class - 0,5; 1,0.

Measuring ranges - 1 A; 2 A; 2,5 A; 5 A; 10 A.

Maximum permissible error at 20±5° C:

- The end value of the measuring range for modifications E514/1-3 - no more than ±0,5%;

- The end value of the measuring range for modifications E514/4,5 - no more than ±1,0.

Maximum permissible additional error equal to the limit of permissible basic error in:

- Frequency deviation of ±10% from outside the normal range of frequencies;

- The frequency deviates from the normal limits of the frequency to any frequency in the working frequency range.

Maximum permissible additional error caused by temperature variation from normal to any within the operating temperature for every 10° C - ±0,5% of full scale range.

Housing units - plastic.

The moving part is mounted on ammeters E514 banners.

Tension stretch marks - 0,75 N.

Reading device - drag pointer.

Sedation moving part - liquid.

Scale length - 113 mm.

Settling time moving part - 4.

Dimensions - 140Í195Í105 mm.

Weight - no more than 1,3 kg.

Operating conditions E514:

Ambient temperature:

- Modifications to E514/1, E514/2, E514/3 - +10° C to +35° C;

- Modifications to E514/4, E514/5 - from -15° C to +40° C.

Relative humidity at +30° C:

- For modifications E514/1, E514/2, E514/3 - 80%;

- For modifications E514/4, E514/5 - 90%.

The degree of resistance to mechanical stress - ordinary.

Degree of protection against external magnetic influences - II category.

E514 devices used in laboratories of industrial enterprises, scientific research institutes, power grids, schools, etc.

Photos: E514

E514 ammeter image.
E514 ammeter image.
E514/1 panel view.
E514/1 panel view.
E514/1 side view (terminals, switches).
E514/1 side view (terminals, switches).
E514/1 side view.
E514/1 side view.
E514/1 side view.
E514/1 side view.
E514/1 bottom view.
E514/1 bottom view.
E514/3 ammeter image.
E514/3 ammeter image.


Яндекс цитирования