Electrical measuring instruments >> ammeters

D50141

9 999 RUB
8 399 UAH
available:
3 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Ammeter D50141 (D 50141, D-50141)
Designed to measure current, voltage and power in DC and AC.
The final value of the measuring range 5A, 10A
Accuracy class 0.2

D50141 ammeters are designed to measure current, voltage and power in DC and AC.
D50141 ammeters are designed for use in moderate climate in enclosed dry heated rooms, at an ambient temperature of 10 ° to 35 ° C and a relative humidity of 80% (at 25 ° C).
Ammeters D50141-4.1 - Version 0, Division 4.1, designed for use in both dry and humid tropical climate in closed rooms with air conditioned or partially air-conditioned at the ambient temperature from 1 to 45 ° C and a relative humidity of 80% at 25 ° C (according to GOST 15150-69).

Technical data

Ammeter D50141 accuracy class 0.2 in accordance with GOST 8711-78 immediately after the start and during any time of continuous operation.
Change D50141 ammeter readings caused by changes in the frequency of the upper limit of the normal region to any value in the working frequency range does not exceed ± 0,2% of the final value of the measuring range.
The limit of additional error device Ammeter D50141 caused by the influence of external homogeneous constant or variable (frequency within the normal range of frequencies, but not more than 1 kHz) of the magnetic field with the magnetic flux density of 0.2 mT does not exceed ± 0,2% of full scale range measurements.
Response time less than 4s. Dining lighting circuit unit Ammeter D50141 made from AC voltage (220 ± 22) at 50 - 60 Hz via a step-down transformer (supplied with the devices), or directly from an AC or DC voltage of 4V.
Overall dimensions Ammeter D50141 no more 205h290h135 mm, weight of the unit is not more than 4.5 kg. Overall dimensions of the transformer housing no more than 65h85h45 mm, weight of the transformer is not more than 0.5 kg.

 

Ammeter D50141
The final value of the measuring range The resistance of not more than, Ohm Inductance, no more, mH The normal range of frequencies, Hz Operating frequency range, Hz
5 A 0.1 0.03 45-1000 1000-2000
10A 0.05 0.01

Photos: D50141

D50141 аmmeter image.
D50141 аmmeter image.
D50141 panel view.
D50141 panel view.
D50141 side view (terminals, switches).
D50141 side view (terminals, switches).
D50141 side view.
D50141 side view.
D50141 side view.
D50141 side view.
D50141 bottom view.
D50141 bottom view.


Яндекс цитирования