Selsyns, rotary transformers, electric motors >> transformers rotating >> VTP

VTP-4D KF3.010.045

30 000 RUB
30 000 UAH
available:
16 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Transformer VTP-4D KF3.010.045 rotating multi odnootschetny open-frame (VTP4D, VTP-4-D,  VTP 4D)
 
Rotary transformers VTP-4D is a two-pole contact four stretch wrapping machines.
Depending on the scheme and the inclusion mode (function) devices transformer rotating multi odnootschetny open-frame VTP-4D are divided into sine-cosine (Synchro), output voltage which is proportional to the sine (cosine) the angle of rotation of the rotor, and linear (LVT), the output voltage which varies linearly proportional to the angle of ± 60 °.
 
Technical characteristics of the instrument transformers VTP-4D rotating multi-pole frameless odnootschetnye:
 
Operation - Synchro, VTDP-D;
The current instrument transformer VTP-4D rotating multi odnootschetny open-frame - 130mA;
Nominal voltage - 12V;
Maximum Output Voltage - 31.2 V;
Residual EDS instrument transformer VTP-4D rotating multi odnootschetny open-frame - 25mV;
Nominal frequency of the excitation voltage - 400 Hz;
Operating frequency range of excitation voltage - 380Gts-4200Gts;
Change the position of agreement with the ambient temperature changes - 40ugl.s;
The steepness of the instrument transformer VTP-4D rotating multi odnootschetny open-frame - 40mV/ugl.min;
The ratio of residual to the steepness of the EMF - 0.6 ang;
Phase shift of the output EMF - 14ugl.grad;
Rotary transformers VTP-4D are divided into accuracy classes:
- Transformer VTP-4D 1 Class 4A accuracy (1st class. T) has the characteristics:
- Accuracy of repetition TPD composed of VTP-4, in the range of angle ± 45 º - ± 0,15 ang;
- Accuracy of repetition TPD composed of VTP-4, in the range of angle of ± 3 º - ± 0,15 ang;
- Transformer VTP-4D Class 2 accuracy (2 cl. T) has the characteristics:
- Accuracy of repetition TPD composed of VTP-4, in the range of angle ± 45 º - ± 0,2 ang;
- Accuracy of repetition TPD composed of VTP-4, in the range of angle of ± 3 º - ± 0,2 ang;
- Transformer VTP-4D 3 Class 4A accuracy (3 cl. T) has the characteristics:
- Accuracy of repetition TPD composed of VTP-4, in the range of angle ± 45 º - +0,3 ang;
- Accuracy of repetition TPD composed of VTP-4, in the range of angle of ± 3 º - ± 0,3 ang;
- Transformer VTP-4D 4 class accuracy (4 cl. T) has the characteristics:
- Accuracy of repetition TPD composed of VTP-4, in the range of angle ± 45 º - ± 0,5 ang;
- Transformer VTP-4D 5 class accuracy (5 cl. T) has the characteristics:
- Accuracy of repetition TPD composed of VTP-4, in the range of angle ± 45 º - ± 1ugl.min;
Dimensions instrument transformer rotating VTP-4D multi odnootschetny open-frame:
- Diameter - 100 mm;
- Length - 18mm;
Unit weight transformer VTP-4D rotating multi odnootschetny open-frame - 0.5 kg;
Vibration loads:
- Frequency range - up to 3000Gts;
- Acceleration - 200m / s 2;
Shock - 750m / s 2;
Ambient temperature - -60 ° C to +100 º C;
Relative humidity at 35 ° C - 98%;
Warranty life instrument SPM-4D rotating transformer open-frame multi-odnootschetny - 15,000 hours;
The manufacturer guarantees the quality of the instrument transformer VTP-4D rotating multi odnootschetny open-frame the technical requirements specifications subject to user terms and conditions of storage, transportation, installation, operation and technical specifications established by the operational documentation.