Radiometric devices >> devices for checking, calibration and metrology

V1-12 (B1-12)

34 999 RUB
13 999 UAH
available:
18 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Differential voltmeter V1-12 for checking voltmeters (V112, V1 12, b1-12, b1 12, b112)

Designed for the issuance of calibrated discrete values ​​of DC voltage and current.
The drift of the output voltage (in percent) for 8 hours is not more than ± (0,001 + 0,0001 Uc / U) for 2000 hours - less than ± (0,004 + 0,0004 Uc / U).
The maximum load current at voltages up to 100V - 110mA at a voltage above 100 V - 11 mA.

Differential voltmeter V1-12 for checking voltmeters  is designed for the issuance of calibrated discrete values ​​of DC voltage and current and is used as a multi-valued model measures for the verification of measuring instruments DC.
Differential voltmeter V1-12 for checking voltmeters  can also be used as a measuring amplifier with the DC-gain of 1, 10 and 100, as well as the differential voltmeter for measuring DC voltage.
Differential voltmeter V1-12 for checking voltmeters  has an analog output that provides the ability to measure and record volatility (increments) DC voltage.
 
Specifications,  Voltmeter V1-12
 
Specifications device V1-12 calibrated voltage source mode are shown in Table. 1.
The drift of the output voltage (in percent) for 8 hours is not more than ± (0,001 + 0,0001 Uc / U) for 2000 hours - less than ± (0,004 + 0,0004 Uc / U).
The maximum load current at voltages up to 100V - 110mA at a voltage above 100 V - 11 mA. Base unit mode currents are shown in Table. 2 in differential mode voltmeter - Table. 3. Input impedance voltmeter device mode no less than 10 9 ohms. Power consumption 100 VA. Dimensions 490 x175x 478 mm, weight 22 kg. The unit V1-12 corresponds to TU HV2.085.006.
Table 1
 

The range of output

Voltage
The basic error of the output voltage,%

Output

Resistance in ohms
with respect to e. emf. taking into account the measures e. d C; 1
0.1 mV-100mV ± (0,015 + 0,005 Uc / U) ± (0,02 + 0,005 Uc / U) 10
1mkV-1B ± (0,002 + 0,0001 Uc / U) ± (0,005 + 0,0001 Uc / U) 100
10mkV-10V ± (0,0008 + 0,0001 Uc / U) ± (0,005 + 0,0001 Uc / U) 0,001
100mkV-100B ± (0,002 + 0,0002 Uc / U) ± (0,005 + 0,0002 Uc / U) 0,001
1 mV-1000V ± (0,0025 + 0,0002 Uc / U), - if u ≤ 500; ± 0,005-for u> 500 ± (0,006 + 0,0002 Uc / U), - if u ≤ 500; ± 0,01-for u> 500 0,001

Table 2
 
Output current range The basic error of the current% The maximum load voltage, V
1nA-1mA ± (0,015 + 0,001 Ik / I) 1000V
10on-10mA ± (0,015 + 0,001 Ik / I) 1000V
100nA-100mA ± (0,025 + 0,001 Ik / I) 1000 - for I ≤ 10 mA, 100 - with I> 10 mA

Table 3
 
Measurement range The relative error of measurement,%
1mkV-1B ± (0,005 + 0,0015 Uc / U)
10mkV-10V ± (0,005 + 0,0003 Uc / U)
100mkV-100B ± (0,005 + 0,0003 Uc / U)
1 mV-1000V ± (0,006 + 0,0003 Uc / U) - if U ≤ 500 V; ± 0,01 - at U> 500V

Photos V1-12

V1-12 (B1-12) device image.
V1-12 (B1-12) device image.
V1-12 (B1-12) front view.