Selsyns, rotary transformers, electric motors >> transformers rotating >> SKT

SKT-232D

3 000 RUB
3 000 UAH
available:
62 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Transformer SKT-232D pole revolving, open-frame (SKT232D, SKT-232-D, SKT 232 D, SKT 232D, SKT232-D, SKT232 D)
 
Rotary transformers SKT-232D is a four stretch wrapping machines.
Depending on the scheme and the inclusion mode (function) open-frame devices rotating transformer pole SKT-232D divided into sine-cosine (Synchro), output voltage which is proportional to the sine (cosine) the angle of rotation of the rotor, and linear (LVT), the output voltage which varies linearly proportional to the angle of ± 60 °.
 
Technical characteristics of the instrument transformers SKT-232D rotating two-pole open frame:
 
Purpose - VTDP-D;
The change of ratio when the ambient temperature at every 40 ° C - 3%;
Nominal frequency of the excitation voltage instrument transformer SKT-232D rotating open-frame pole - 400Hz;
Operating frequency range of excitation voltage - 380Gts-420Gts;
Nominal excitation voltage - 36V;
Operating range of excitation transformer unit SKT-232D rotating open-frame pole - 32.4 B-37, 8V;
Input impedance idling - 750 ohms;
Turns Ratio - 0.58;
Rotary transformers SKT-232D are divided into accuracy classes:
- Transformer SKT-232D Class 1 accuracy (1st class. T) has the characteristics:
- Error display the sine function - ± 0,1%;
- Asymmetry of the null positions of the rotor - ± 2,5 ang;
- The ratio of residual to the steepness of the EMF - ± 5,0 ang;
- The inequality of the coefficients of transformation - 2.5 ang;
- Indicators of the accuracy TPD composed of Tues-232D SKT, SKT-232P:
- Accuracy class transmitter and receiver - 0.1;
- Accuracy of following TPD - ± 5ugl.min;
- The ratio of residual to the steepness of the EMF - 7ugl.min;
- Slope - 2mV/ugl.min;
- Transformer SKT-232D Class 2 accuracy (2 cl. T) has the characteristics:
- Error display the sine function - ± 0,2%;
- Asymmetry of the null positions of the rotor - ± 5,0 ang;
- The ratio of residual to the steepness of the EMF - 7.5 ang;
- The inequality of the coefficients of transformation - 5.0 ang;
- Indicators of the accuracy TPD composed of Tues-232D SKT, SKT-232P:
- Accuracy class transmitter and receiver - 0.2;
- Accuracy of following TPD - ± 10ugl.min;
- The ratio of residual to the steepness of the EMF - 10ugl.min;
- Slope - 2mV/ugl.min;
- Transformer SKT-232D Class 3 accuracy (3 cl. T) has the characteristics:
- Error display the sine function - ± 0,35%;
- Asymmetry of the null positions of the rotor - ± 10ugl.min;
- The ratio of residual to the steepness of the EMF - 10ugl.min;
- The inequality of the coefficients of transformation - 10ugl.min;
- Indicators of the accuracy TPD composed of Tues-232D SKT, SKT-232P:
- Accuracy class transmitter and receiver - 0.35;
- Accuracy of following TPD - ± 20ugl.min;
- The ratio of residual to the steepness of the EMF - 15ugl.min;
- Slope - 2mV/ugl.min;
Dimensions instrument transformer SKT-232D pole revolving, open-frame:
- Length - 32mm;
- Diameter - 12mm;
Weight - 0.0045 kg;
Vibration loads instrument transformer SKT-232D pole revolving, open-frame:
- Frequency range - up to 300 Hz;
- Acceleration - 100m / s 2;
Shock - 120m / s 2;
Ambient temperature - -60 ° C to +100 º C;
Relative humidity at 40 ° C - 98%;
Warranty life instrument 232D SKT-rotating open-frame transformer pole - 3000 hours;
The manufacturer guarantees the quality of the instrument transformer SKT-232D revolving, open-frame pole technical requirements specifications subject to user terms and conditions of storage, transportation, installation, operation, established specifications and operational documentation. 

Photos SKT-232D

SKT-232D device image.
SKT-232D device image.
SKT-232D accessories and spare parts.
SKT-232D accessories and spare parts.
SKT-232D front view.
SKT-232D front view.
SKT-232D side view.
SKT-232D side view.
SKT-232D rear view.
SKT-232D rear view.


Яндекс цитирования