ШМ-1 ШМ-1 BL-1 sound level meter.
4.9 63

Sound Level Meter SHM-1 (SHM-1, SHM 1)
     Measuring instrument consisting of PI-14 and a condenser microphone capsule M-101 is designed to measure the sound level and has a frequency response of A and C.
     The sound meter is used for measuring noise in industrial enterprises in towns and other populated areas;
     Frequency range - 20Hz-8000Hz.

ШМ-1 BL-1 sound level meter.

Price:

on request

 

Product information updated 23 December 2023.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

Product information updated 23 December 2023.

Found cheaper?

Let us know. Our price is the best. 

Warranty:

12 months.

Warranty extension up to 5 years. 

Terms of delivery:

To all regions of the country, international delivery. 

Technical characteristics

Sound Level Meter SHM-1 (SHM1, SHM 1)
 
Sound Level Meter CMM-1 consists of a measuring instrument PI-14 and the capsule condenser microphone M-101 is designed to measure the sound level and has a frequency response of A and C.
The sound meter is used for measuring noise in industrial plants, cities and other settlements.
 
Technical characteristics of the instrument sound level meters CMM-1:
 
Normal conditions of use:
- Ambient temperature - 20 º C ± 5 ° C;
- Relative humidity - 65% ± 15%;
- Atmospheric pressure - 100kPa ± 4kPa (750mm.rt.st. ± 30mm.rt.st.;
Working conditions of use:
- Ambient temperature - from -10 º C to +40 ° C;
- Relative humidity - 90% at a temperature of 30 ° C;
- Atmospheric pressure - 86kPa 106kPa-(650mm.rt.st.-800mm.rt.st.);
Frequency range - 20Hz-8000Hz;
The frequency characteristics of A and C sound level meter, the instrument correspond to BL-1 Table 1;
 
Table 1: Frequency response of A and C sound level meter instrument CMM-1
 
Rated frequency, Hz
Relative frequency response sound level meter. DB
Maximum deviation dB
And
C
20Hz
-50.5 DB
-6.2 DB
± 3,0 dB
25Hz
-44.7 DB
-4.4 DB
± 3,0 dB
31.5 Hz
-39.4 DB
-3.0 DB
± 3,0 dB
40Hz
-34.6 DB
-2.0 DB
± 2,0 dB
50Hz
-30.2 DB
-1.3 DB
± 2,0 dB
63Hz
-26.2 DB
-0.8 DB
± 2,0 dB
80Hz
-22.5 DB
-0.5 DB
± 2,0 dB
100Hz
-19.1dB
-0.3 DB
± 1,5 dB
125Gts
-16.1 DB
-0.2 DB
± 1,5 dB
160Hz
-13.4 DB
-0.1 DB
± 1,5 dB
200Hz
-10.9 DB
0dB
± 1,5 dB
250Hz
-8.6 DB
0dB
± 1,5 dB
315Gts
-6.6 DB
0dB
± 1,5 dB
400Hz
-4.8 DB
0dB
± 1,5 dB
500Hz
-3.2 DB
0dB
± 1,5 dB
630Gts
-1.9 DB
0dB
± 1,5 dB
800Hz
-0.8 DB
0dB
± 1,5 dB
1000Hz
0dB
0dB
± 1,5 dB
1250Gts
0.6 dB
0dB
± 1,5 dB
1600Gts
1.0 dB
-0.1 DB
± 2,0 dB
2000Hz
1.2 dB
-0.2 DB
± 2,0 dB
2500Gts
1.3 dB
-0.3 DB
± 2,5 dB
3150Gts
1.2 dB
-0.5 DB
± 2,5 dB
4000Hz
1.0 dB
-0.8 DB
± 3,0 dB
5000Hz
0.5 dB
-1.3 DB
± 3,5 dB
6300Gts
-0.1 DB
-2.0 DB
± 4,5 dB
8000Hz
-1.1 DB
-3.0 DB
± 5,0 dB
 
The frequency response of the free field to meet the requirements of Table 1 with the frequency response;
Frequency response sound level meter instrument BL-1 to diffuse field meets the requirements of Table. 1 for the frequency response of C;
The frequency response of pressure corresponds to the requirements of Table 1. For the frequency response of C, minus the diffraction correction given in Table.2;
 
 
Table 2 Diffraction correction unit sound level meter, BL-1
 
Frequency
250Hz
315Gts
400Hz
500Hz
630Gts
800Hz
1000Hz
1250Gts
The diffraction correction
0dB
0dB
0.1 dB
0.15 dB
0.2 dB
0.4 dB
0.6 dB
0.8 dB
Frequency
1600Gts
2000Hz
2500Gts
3150 Gts
4000 Hz
5000 Hz
6300 Gts
8000 Hz
The diffraction correction
1.1 dB
1.3 dB
1.6 dB
2.3 dB
2.9 dB
4.1 dB
5.6 dB
8.2 dB
 
Changes in the level of sensitivity of different angles of incidence of the sound wave relative to the reference value when the direction is in the range given in Table. 3 for a range of angles from +90 º to -90 °;
 
Table 3 Changes in the level of sensitivity of different angles of sound wave sound-level meter instrument BL-1 with respect to the reference value at the direction of
 
Frequency
from 31.5 Hz to 1,000 Hz
from 1000Hz to 2000Hz
from 2000Hz to 4000Hz
from 4000Hz to 8000Hz
Limiting changes in the level of sensitivity
3.0 dB
5.0 dB
8.0 dB
14.0 dB
 
Linearity of the amplitude of the amplifier and the measuring device relative to the reference sound level does not exceed the values ​​listed in Table. 3a;
 
Table 3a Linearity amplitude of the amplifier and the measuring device relative to the reference sound level meter, sound level instrument CMM-1
 
Deviation in amplitude
in the range of scales
± 1,0 dB
in the range of overlap
± 1,5 dB
 
The maximum permissible deviation of the amplitude characteristic between the levels, the difference does not exceed 10 dB does not exceed:
1) to measure the difference between the levels of 1 dB - ± 0,3 dB;
2) measuring the difference in levels to 10 dB - ± 0,6 dB;
3) overlap for the difference in levels of 5dB - ± 1,5 dB;
The upper limit of the dynamic range of the instrument sound level meter, BL-1 - at least 130dB;
Deviation of the real dependence of the output signal when the input signal - no more than ± 1dB;
The lower limit of the dynamic range of the instrument sound level meter, BL-1 - less than 30dB;
Noise level - not less than 5 dB below the lower limit of dynamic range;
Gain control range - not less than ± 3,0 dB;
The error limits of measurement with respect to the switch of 80 dB when you switch - no more than ± 0,7 dB;
The error of the grading scale of the instrument sound level meter, BL-1 in the working range - less than ± 1,0 dB;
Characteristics of Rectifier - square with crest factor 3;
Maximum deviation readings - no more than ± 1,0 dB;
Sound Level Meter is the temporal characteristics of F (fast) and S (slow) according to the Table. 3b;
 
Table 3b Timing in the F (fast) and S (slow) sound level meter instrument CMM-1
 
Time response
The frequency of the pulse
Pulse duration
The difference in readings
The limiting deviation of the
S (slow)
from 1000Hz to 2000Hz
Infinity
500ms
0dB
-4.1 DB
0dB
± 2,0 dB
F (Fast)
from 1000Hz to 2000Hz
Infinity
200ms
0dB
-1.0 DB
0dB
1.0 dB, -2.0 dB
 
Additional error due to the connection of additional devices with an input resistance of 10 ohms, no more than ± 0,5 dB;
Sound Level Meter has an electrical and acoustic calibration;
Indication when the power is always sound level meter, BL-1 under constant external conditions and not later than 10 minutes after its inclusion does not change within 1 hour by more than ± 0,5 dB;
Equivalent sound level when exposed to an alternating magnetic field of 80 A / m at a frequency of 50 Hz - not more than 50 dB;
THD at output jack does not exceed 10% in the frequency range from 200Hz to 1000Hz, with an upper limit of measurement;
Additional error of the instrument sound level meter, GL-1 from the ratio of harmonics at frequencies above 31.5 Hz at the upper limit of each range does not exceed ± 1 dB;
Equivalent sound level caused by wind speeds in the range of air flow 1m/s-8m/s, no more than 80dB;
When placing the unit sound level meter, BL-1 in the sound field with a level of 106dB his testimony when replacing condenser microphone capsule equivalent falls not less than 40 dB;
The maximum permissible sound level meter error at the reference frequency due to temperature, the operating temperature range from -10 º C to +40 ° C - no more than ± 0,5 dB;
The maximum permissible sound level meter error due to the humidity from 65% to 90% at 40 ° C - no more than ± 0,5 dB;
The maximum sound level meter reading device BL-1, due to exposure to vibration with an acceleration of 1m / s in the frequency range from 20Hz to 1000Hz - no more than 70 dB;
Continuous operation sound level meter, including the time for establishing the operating mode for 5 minutes, at least 8 hours;
Sound Level Meter can withstand the mechanical impact:
- Vibration frequency 10Hz-70Hz with maximum acceleration 2m/s-40m/s;
- 10-50 beats per minute at maximum acceleration of 50 m / s, pulse width 6.0 ms-12, 5 ms;
- The total number of strokes - 1000;
- In the extreme conditions of transportation of the unit sound level meter, a stand-CMM 80-120 beats per minute with a maximum acceleration of 30 m / s with duration of exposure to 2 hours;
Average life - 8 years.
Rate the product: ШМ-1
Number of views: 1609
Product rating: 4.4
Number of grades: 270
* rating and all product statistics are updated once a month; information is current as of 11 January 2024

Leading online store Zapadpribor - a huge selection of measuring equipment for the best value and quality. So you can buy inexpensive devices, we monitor competitors' prices and are always ready to offer a lower price. We only sell quality products at the best prices. On our site you can buy cheaply as the latest innovations and proven equipment from the best manufacturers.

The site includes a special offer «buy at the best price» - if other Internet resources (bulletin board, forum or announcement of another online service) in products presented on our site, the lower price, we will sell it to you even cheaper! Buyers also additional discount for leaving a review or photo of use of our products.

In the price list contains not the whole range of products offered. Prices of goods, not included in the price list can learn to contact the manager. Also, our managers You can get detailed information about how cheap and profitable to buy instrumentation wholesale and retail. Telephone and e-mail for advice on the purchase , delivery or receipt are shown on the description of the goods. We have the most qualified staff, quality equipment and the best price.

 

Online store Zapadpribor - the official manufacturer's dealer test equipment. Our goal - selling high quality goods with best price offer and service to our customers. Our store can not only sell you the necessary instrument, but also offer additional services to its calibration, repair and installation. That you have a pleasant experience when shopping on our site, we have provided special gifts guaranteed to the most popular products.

 

We offer fast international shipping to almost every country in the world: Australia, Austria, Azerbaijan, Albania, Algeria, Anguilla, Angola, Antigua and Barbuda, Argentina, Aruba,  Bahamas, Bangladesh, Barbados, Bahrain, Belize, Belgium, Benin, Bermuda, Bulgaria, Bolivia, Bonaire, Sint-E. and Saba, Bosnia and Herzegovina, Botswana, Brazil, British Virgin Islands, Brunei Darussalam, Burkina Faso, Burundi, Bhutan, VietNam, Vanuatu, Vatican City, Venezuela, Armenia, Gabon, Guyana, Haiti, Gamia, Gambia, Ghana, Guatemala, Guinea, Gibraltar, Honduras, Hong Kong, Grenada, Greenland, Greece, Georgia, Denmark, Democratic Republic of the Congo, Jersey, Djibouti, Dominica, Dominican Republic, Ecuador, Eswatine, Estonia, Ethiopia, Egypt, Zambia, Zimbabwe, Jordan Indonesia, Ireland, Iceland, Spain, Italy, Cape Verde, Kazakhstan, Cayman Islands, Cambodia, Cameroon, Canada, Qatar, Kenya, Kyrgyzstan, China, Cyprus, Kiribati, Colombia, Comoros, Congo, Korea (Rep.), Costa Rica, Kot-d'Ivoire, Cuba, Kuwait, Curacao, Laos, Latvia, Lesotho, Lithuania, Liberia, Lebanon, Libya, Liechtenstein, Luxembourg, Myanmar, Mauritius, Mauritania, Madagascar, Macao, Malawi, Malaysia, Mali, Maldives, Malta, Morocco, Mexico, Mozambique, Moldova, Monaco, Monaco, Namibia, Nauru, Nepal, Niger, Nigeria, Netherlands, Germany, New Zealand, New Caledonia, Norway, UAE, Oman, Cook Islands, Pakistan, Palestine, Panama, Papua New Guinea, Paraguay, Peru, South Africa, Poland, Portugal, Republic of Chad, Rwanda, Romania, El Salvador, Samoa, San Marino, Saudi Arabia, Swaziland, Seychelles, Senegal, Saint Vincent and the Grenadines, Saint Kitts and Nevis, Saint Lucia, Serbia, Singapore, Sint Maarten, Slovakia, Slovenia, Solomon Islands, United Kingdom of Great Britain and Northern Ireland, Sudan, Suriname, East Timor (Timor-Leste), USA, Sierra Leone, Tajikistan, Taiwan, Thailand, Tanzania (United Republic of), Togo, Tonga, Trinidad and Tobago, Tuvalu, Tunisia, Turkey, Turkmenistan, Uganda, Hungary, Uzbekistan, Uruguay, Faroe Islands, Fiji, Philippines, Finland, France, French Polynesia, Croatia, Central African Republic, Czech Republic, Chile, Montenegro, Switzerland, Sweden, Sri Lanka, Jamaica, Japan.

We also provide such metrological procedure: calibration, tare, graduated, testing of measuring instruments.

The online store takes an active part in such procedures as electronic bidding, tender, auction.

If there is no site in the descriptive information you need on the device you can always turn to us for help. Our qualified managers will update for you on the technical characteristics of the device from its technical documentation: user manual, certificate, form, operating instructions, diagram. If necessary, we will take a photo of your device, or a device stand. You can leave feedback on the unit purchased from us, the meter, the device, indicator, or product. Your review for your approval will be published on the site without contact information.

 

Description of the instruments taken from the technical documentation or technical literature. Most pictures of products made directly by our experts prior to shipment of goods. In the description of the device provided the main technical characteristics of the instrument: nominal measuring range, accuracy class, scale, supply voltage, size (size), weight. If the site you see the discrepancy device name (model) specifications, photo or documents attached - let us know - you will get a useful gift with-selling device.

 

While the need to clarify the overall weight and size or the size of the individual meter you can in our service center. If you need our engineers will help you choose the most complete analog or a suitable replacement for the device you are interested. All counterparts and replacement will be tested in one of our laboratories with the full compliance to your requirements.

In the technical documentation for each device or product, information is provided on the list and amount of precious metals content. The documentation gives the exact weight in grams of precious metals: Au gold, palladium Pd, platinum Pt, silver Ag, tantalum Ta and other platinum group metals (PGM) per unit item. These precious metals are found in nature in very limited quantities and therefore have such a high price.

On our website you can familiarize yourself with the technical characteristics of devices and obtain information on the content of precious metals in devices and radio components manufactured in the USSR. We draw your attention to the fact that often the actual content of precious metals differs by 10-25% from the reference one in a smaller direction! The price of precious metals will depend on their value and mass in grams.

All text and graphic information on the site is informative. The color, shade, material, geometric dimensions, weight, content, delivery set and other parameters of the goods presented on the site may vary depending on the batch of production and year of manufacture. Check with the sales department for more information.

 

If you can make repairs to the device yourself, our engineers can provide you with a complete set of necessary technical documentation: circuit diagram TO, ER, FD, PS. We also have an extensive database of technical and metrological documents: technical specifications (TS), the terms of reference (TOR), GOST (DSTU), the industry standard (OST) test procedure, the method of certification, verification scheme for more than 3,500 types of measuring equipment from the manufacturer this equipment. From the site you can download all the necessary software (the software driver) is required for the product purchased.

We carries out repairs and maintenance of measuring equipment in more than 75 different factories of the former Soviet Union and CIS.

We also have a library of legal documents that are related to our field of activity: the law, code, ordinance, decree, temporary position.