Radiometric devices >> distortion meters

S6-11 (C6-11)

41 999 RUB
17 639 UAH
available:
20 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Measuring nonlinear distortion S6-11 (S611, S6 11, c6-11, c6 11, c611)

For automatic measurement of harmonic distortion (Kg) in the frequency range from 20 Hz to 199.9 kHz.
Measurement of harmonics within:
0.1, 0.3, 1, 3, 10, and 30% in the frequency range from 20 Hz to 19.9 kHz;
0.3, 1, 3, 10, and 30% at frequencies above 19.9 kHz to 199.9 kHz;
Minimum measurement THD:
0.03% in the frequency range from 20 Hz to 19.9 kHz;
0.1% in the frequency range above 199.9 kHz to 19.9 kHz.

Measuring nonlinear distortion S6-11 automatic for automatic measurement of harmonics ratio (Kg) in the frequency range from 20 Hz to 199.9 kHz.
The device also measures the rms ac voltage in the frequency range from 20Hz to 1MHz.
In the measurement mode, the instrument measures the harmonic frequency of the input signal in the frequency range from 20 Hz to 199.9 kHz.
Normal operating conditions the instrument measuring nonlinear distortion S6-11 are as follows:
Ambient temperature, ° C 20 ± 5;
relative humidity,% 3080;
atmospheric pressure, kPa (mm Hg) 84-106 (630-795);
voltage, V 220 ± 4,4;
Frequency, Hz, 50 ± 0,5 with harmonic content up to 5%
The working conditions of operation of the device are:
ambient temperature from 5 to 40 ° C;
relative humidity 80% at temperature 25 ° C;
atmospheric pressure, kPa (mmHg) 60 (450) to 106 (795);
mains voltage (220 ± 22) V (50 ± 0,5) Hz with harmonic content up to 5%.
 
Technical data
 
Measuring nonlinear distortion S6-11 provides automatic measurement of harmonic distortion on the scales:
0.3, 1, 3, 10, and 30% in the frequency range from 20Hz to 199.9 Hz and over 19.9 kHz to 199.9 kHz, 0.1, 0.3, 1, 3, 10, and 30% in the frequency range more than 199.9 Hz to 19.9 kHz.
Minimum measurement THD:
0.03% in the frequency range above 199.9 Hz to 19.9 kHz;
0.1% in the frequency range from 20 Hz to 199.9 Hz and over 19.9 kHz to 199.9 kHz.
The limits of permissible values ​​of absolute basic error in the measurement instrument harmonic distortion as quoted in Table. 1.
 
Table 1
 
Frequency band
The limits of permissible values ​​of absolute basic error (ΔKg),%
20 Hz to 199.9 Hz
± (0,05 + 0,06 QGP)
Over 199.9 Hz to 19.9 kHz
± (0,05 + 0,02 QGP)
More than 19.9 kHz to 199.9 kHz
± (0,1 + 0,06 Kgp)

where MSE - scale value, which is measured as a percentage
The limits of permissible values, an additional instrument error in the measurement of harmonic distortion caused by the deviation of the ambient temperature from the normal, equal to half the limits permitted by the basic values ​​of the absolute error of the instrument for every 10 ° C change in temperature.
Measuring nonlinear distortion S6-11 provides a measurement mode, the harmonic measurement frequency of the input signal with KG not more than 30% in the frequency range from 20 Hz to 1,99,9 kHz with a signal / noise ratio of at least 40 dB.
The limits of permissible values ​​of absolute basic error in the measurement of the frequency of the instrument:
± 0,02 f in the frequency range from 20 Hz to 99.9 Hz.
± 0,01 f at frequencies above 99.9 Hz to 199.9 kHz,
where f - frequency of the input signal in Hz.
Voltmeter device provides a measurement of rms voltage sinusoidal and distorted form with KG not more than 30% in the frequency range from 20Hz to 1MHz on the scales: 0.3 mV, 1 mV: 3mV, 10-30mV, 100mV and 0.3V, 1B, 3B; 10V, 30V, 100V.
The minimum voltage of 100 mV measured.
The limits of permissible values ​​of absolute basic error voltmeter device in volts:
± (0,04 Un + 20-10 -6) in the frequency range from 20 Hz to 200 kHz; ± (0,06 Un + 20-10 -6) in the frequency range above 200 kHz to 1 MHz,
The limits of permissible additional error voltmeter instrument caused by ambient air temperature deviation from the normal, equal to half the limits of admissible values ​​of the absolute basic error of the voltmeter for every 10 ° C change in temperature.
Measuring nonlinear distortion S6-11 provides automatic calibration coefficient measured harmonic input voltage range of 0.1 up to 100. The device automatically switches the measuring range and voltage harmonic distortion. The device has an output DC voltage proportional to the measured values.
The maximum measurement time harmonic factor less than 20, the maximum voltage is not measuring time more than 10 seconds.
Attenuation highpass filter unit is not less than 15 dB at a frequency of 400 Hz relative to the level at 1000 Hz. The input resistance of the device is not less than 100 k in the harmonic measurement mode, and at least 1MOmv-mode voltage measurement.
Input capacitance of the device is not more than 100 pF. The device provides its specifications after 15 minutes from power on in normal conditions and after 30 minutes in conditions different from normal.
Measuring nonlinear distortion S6-11 saves specifications when powered from the mains alternating current voltage (220 ± 22), frequency (50 ± 0,5) Hz and harmonic content up to 5%.
The power consumed by the device from the network at the rated voltage does not exceed 95 VA.
The device allows continuous operation under the operating conditions for a time not less than 8 hours, while maintaining performance.
Mean time between failures (It) is not less than 5000 hours Gamma-percent life instrument (Tr γ) of at least 10,000 hours at a confidence level (γ), equal to 80%. Gamma-percent service life of the device (p γ) is not less than 10 years at P (γ), equal to 80%. Gamma-percent storage time (Tc γ) pr confidence level (γ), equal to 50% of at least 10 years in:
ambient temperature from 5 to 40 ° C;
relative humidity up to 80% at 25 ° C temperature round;
at least 5 years in:
ambient temperature from minus 50 to plus 40 ° C;
relative humidity of 98% at a temperature of 25 C.
Average recovery time (Te) not more than 10 hours
The probability of no latent failures of at least 0.97 for the calibration interval 24 months. at an average utilization rate of 0.04.
Overall dimensions measuring nonlinear distortion S6-11 is not more than 490 mm ​​h355h135; 560x560x190 mm ​​in the packing box; x628x318 668 mm in the transport container.
Unit weight is not more than 13 kg, 25 kg with packing box, 60 kg with a transport container.

Photos С6-11

S6-11 (C6-11) device image.
S6-11 (C6-11) device image.
S6-11 (C6-11) view panel of the device.
S6-11 (C6-11) view panel of the device.
S6-11 (C6-11) side view.
S6-11 (C6-11) side view.
S6-11 (C6-11) rear view.
S6-11 (C6-11) rear view.
S6-11 (C6-11) overhead view.
S6-11 (C6-11) overhead view.
S6-11 (C6-11) bottom view.
S6-11 (C6-11) bottom view.


Яндекс цитирования