Meter ratio of the amplitude modulation of S2-23 (S223, S 2 23, S-2-23, c2-23, c223, c 2 23, c-2-23)
 
The instrument measuring the amplitude modulation coefficient S2-23 has a manual, automatic and remote software control modes and a digital readout.
High sensitivity, low distortion can own widely used instrument for setting and checking the TOS and transceiver equipment.
The principle of operation of the device measuring the amplitude modulation coefficient S2-23 is based on the superheterodyne receiver (in the frequency range of 1MHz-500MHz) and a direct gain.
Has modes automatically adjust the frequency of the input signal and remote control software that allows you to embed the device in automated systems with automatic recording of measured values.
 
Technical characteristics of the instrument gauges ratio of the amplitude modulation of S2-23:
 
Parameters
Mode of the device measuring the amplitude modulation coefficient S2-23
manual
automatic tuning
Carrier frequency range, MHz
0.01 MHz-500 MHz
1MHz-400MHz
The range of modulating frequencies the instrument measuring the amplitude modulation coefficient S2-23 kHz
0.03 kHz, 0, 4 kHz (0.01 MHz-0, 045MGts), 0.03 kHz, 20 kHz (0.08 MHz-4 MHz), 0.03 kHz to 20 kHz (4 MHz-500 MHz)
0.03 kHz to 20 kHz (1 MHz-4 MHz), 0.03 kHz, 60kGts (4 MHz-400 MHz)
The limits of measurement of the AM,%
0.3% -100%
0.3% -95%
The basic error of measurement of the AM,%
(1,5 ∙ 10 -2 M 0.2)% (up to 450 MHz), (2,5 ∙ 10 -2 M 0.4)% (over 450MHz)
(1,5 ∙ 10 -2 M 0.2)%
Sensitivity of the instrument measuring the amplitude modulation coefficient S2-23 mV
40mV (1MHz-60MHz), 80mV (0.01 MHz-1, 5 MHz), 70mV (60MHz-450MHz), 120mV (450MHz-500MHz)
40mV (1MHz-60MHz), 70mV (60MHz-400MHz)
The level of your background and noise (1MHz-250MHz),%
0.1% -0.3%
0.1% -0.3%
Harmonic instrument measuring the amplitude modulation coefficient S2-23, %
0.5% -2%
0.5% -2%
 
Parameters
Software and Remote Control
Carrier frequency range, MHz
0.01 MHz-400 MHz
The range of modulating frequencies the instrument measuring the amplitude modulation coefficient S2-23 kHz
0.03 kHz, 0, 4 kHz (0.01 MHz-0, 045MGts), 0.03 kHz, 20 kHz (0.08 MHz-4 MHz), 0.03 kHz, 60kGts (4 MHz-400 MHz)
The limits of measurement of the AM,%
0.3% -95% (1MHz-400MHz), 0.3% and 100% (0.01 MHz-1, 5 MHz)
The basic error of measurement of the AM,%
(1,5 ∙ 10 -2 M 0.2)%
Sensitivity of the instrument measuring the amplitude modulation coefficient S2-23 mV
40mV (1MHz-60MHz), 80mV (0.01 MHz-1, 5 MHz), 70mV (60MHz-400MHz)
The level of your background and noise (1MHz-250MHz),%
0.1% -0.3%
Harmonic instrument measuring the amplitude modulation coefficient S2-23, %
0.5% -2%
  
Dimensions - 490h255h485mm;
Weight of the device measuring the amplitude modulation coefficient S2-23 - 32kg.
The manufacturer guarantees the quality of the instrument measuring the amplitude modulation coefficient S2-23 technical requirements specifications subject to user terms and conditions of storage, transportation, installation, operation, established specifications and operational documentation. 