Radiometric devices >> oscilloscopes >> universal oscilloscope

S1-71 (c1-71)

34 999 RUB
13 999 UAH
available:
3 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Oscilloscope S1-71 universal (S171, S-1-71, S 1 71, S1-71, S-171, S 171, S1 71, c171, c-1-71, c 1 71, c-171, c 171 , c1 71)
 
Oscilloscope S1-71 universal designed to study the form of electrical signals in the frequency range from dc to 100 MHz by visual observation or by means of photographing, measuring the amplitudes in the range from 0.01 V to 60 V and the time intervals of 2 ∙ 10 -8 sec to 1 sec.
 
Technical characteristics of the devices Oscilloscope S1-71 universal:
 
Designed to study the form of electrical signals in the frequency range from dc to 100 MHz by visual observation or by means of photographing, measuring the amplitudes in the range from 0.01 V to 60 V and the time intervals of 2 ∙ 10 -8 s to 1s;
Operating conditions of the oscilloscope:
- Ambient temperature - from -10 ° C to +40 º C at a relative humidity of 65% ± 15%;
- Maximum humidity - up to 95% at +30 º C ± 2 ° C;
- Atmospheric pressure - 750mm.rt.st;
If you are working in countries with tropical climates it is recommended instrument maintenance oscilloscope S1-71 Universal in rooms with air conditioning;
In the case of operation of the oscilloscope in a humid tropical climate in the ordinary room conditions without air conditioning needs additional inclusion of the oscilloscope for a while at least two hours to warm it;
The working part of the device screen oscilloscope S1-71 universal:
- Horizontal - 80mm (10 points);
- Vertical - 48mm (6 points);
The minimum frequency of the sweep, which provides a monitoring and measurement of the test instrument oscilloscope S1-71 universal signal for the fastest scan - no more than 100 Hz;
The line width of the beam, defined by blurring and defocusing - no more than 0.8 mm;
Recording speed when photographing single process on the film KH-4 - no less than 150 km / s;
The bandwidth of the amplifier unit horizontal deflection oscilloscope S1-71 universal - at least 2MHz DC;
The rise of the amplitude-frequency characteristics in the passband is less than ± 15% relative to 0.15 MHz;
The minimum coefficient of variation tract horizontal deflection device oscilloscope S1-71 universal - not more than 0,4 «V / DIV.";
The time for establishing the transition channel performance in vertical position - no more than 20ns;
Step response time amplifiers vertical deflection of less than:
- 4ns - in the "0.005" switch «V / business";
- 3.5 ns - in other positions of the switch «V / business";
- 4.5 ns in the "0,005, 2, 5, 10" switch «V / affairs" and 4ns in other positions of the switch «V / business" for the device oscilloscope S1-71 with a universal probe I22.746.021 and 1:10 divider I22.727.057;
Footnote. In the unsized position handles amplifier Y «smoothly" Step response time is not guaranteed;
Emission characteristics of the transition to vertical amplifier apparatus oscilloscope S1-71 universal no more than:
- 5% - in all positions of the switch "/ div";
- 6% - with the probe I22.746.021;
- 7% - with an external voltage divider I22.727.057 1:10;
Recession vertex transition characteristics of the instrument oscilloscope S1-71 universal (with closed inlet) with a duration of 2 ms test pulse, no more than 10%.
Periodic and random deviations (background network noise, etc.) on the beam line - no more than 2%;
The uneven top of the transfer characteristic (reflection, synchronous pickup) - less than 3%;
Parameters input device oscilloscope S1-71 universal:
- The vertical deflection amplifier:
- Input resistance - 1 MW ± 0,02 MW with an output capacity of 25pF ± 2,5 pF;
- Input resistance with an external voltage divider I22.727.057 1:10 - 1 MW ± 0,025 MW with the input capacitance of 10 pF ± 2,5 pF;
- Input resistance of 1 megohm probe I22.746.021 ± 0,025 MW with the input capacitance of less than 5pF;
- External synchronization input and «X» in the open input:
- Input resistance - a ± 0,025 MW with the input capacitance of less than 30pF;
- «Z» - input resistance - 0.047 megohm ± 0,01 MW;
Coefficient of variation instrument oscilloscope S1-71 should be universal: 0.005 V / div, 0.01 V / div, 0.02 V / div, 0.05 V / div and 0.1 V / div and 0.2 V / div and 0.5 V / Affairs; 1V/del; 2V/del; 5V/del and 10V/del;
The main error of the coefficients of deviation - no more than ± 3% for the device with 1:10 divider probe and I22.727.057 I22.746.021 - no more than ± 5%;
The error coefficient of variation in working conditions - no more than ± 5%, for device universal oscilloscope S1-71 with 1:10 divider probe and I22.727.057 I22.746.021 - no more than ± 7%;
Limits movement of the beam is provided by:
- The vertical offset must be at least two values ​​of the nominal vertical deflection;
- The combination of start and end of the working part of the sweep from the center of the screen;
CRT beam coincidence with the horizontal lines of vertical scale of the instrument oscilloscope S1-71 universal in the operating side of the screen is provided with an accuracy better than 0.5 mm;
Restricted to the total value of the DC and AC voltage at the input channels of the vertical and horizontal deviations of the instrument oscilloscope C1-71 with universal AC coupled and with 1:10 divider probe and I22.727.057 I22.746.021 (packed I26.451.013) - not more 150V;
Maximum voltage of the test instrument oscilloscope S1-71 universal signal does not exceed:
- Inlet channel vertical deflection - 60V;
- Inlet tract horizontal deflection - 40V;
- The input divider I22.727.057 1:10 - 60V;
- At the entrance to the probe:
- No dividers - 0.6;
- With 1:10 divider (I26.451.014) - 6B;
- With a divider 1:100 (I'26 .451.014-01) - 60V;
The working part of the screen:
- Horizontal - 80mm (10 points);
- Vertical - 48mm (6 points)
The displacement of the beam instrumentation oscilloscopes S1-71 universal because of the drift of the vertical deflection amplifier after 15 minutes of warm-up - no more than:
- 2 mV (0.4 cases.) Within 1 minute of work with short-term drift;
- 12mV (2.4 cases.) Within 1 hour of work for long-term drift;
The displacement of the beam when the mains voltage ± 10% - less than 2 mV (0.4 cases.) For 1 minute;
Internal source voltage devices calibrated oscilloscope universal S1-71 generates a U-shaped pulses with a period of time of 0.5 ms and provides a constant voltage of positive polarity with amplitude: 0.03 V, 0.06 V, 0.12 V, 0.3 V, 0.6 V and 6 V;
The error of the amplitude and pulse repetition period of the calibrator - no more than:
- Under normal circumstances - ± 1,5%;
- In working conditions - ± 2%;
The asymmetry of the pulse unit oscilloscope S1-71 universal - no more than 20%.
The main error in measuring the amplitudes of sinusoidal signals at frequencies from 20 MHz to 0MGts and amplitude of the pulse signal value of 0.01 V to 60 V with a pulse width of 20ns to 1 ∙ 10 9 ns - not more than ± 5% at the height of the image to 6 points;
The measurement error of the amplitudes in the working conditions of operation of the device oscilloscope S1-71 universal - no more than ± 10%;
Sweep should be - 0.05 ms / div, 0.1 ms / div, 0.2 ms / div, 0.5 ms / div, 1mks/del, 2mks/del, 5mks/del, 2ms/del, 5ms/del, 10ms / div, 0.1 ms / div, 0.2 ms / div, 0.5 ms / div, 1ms/del, 20ms/del, 50ms/del, 1000ms/del, 10mks/del, 20mks/del, 50mks/del;
The basic error of the instrument sweep oscilloscope S1-71 universal must be no more than:
- ± 6% - in the "x0, a" sweep factor for 0.05 ms / div;
- ± 5% - in positions "x0, 1" and "x1" factor for the rest of the sweep sweep;
The error in the sweep operation of the device operating conditions oscilloscope S1-71 Universal does not exceed:
- ± 8% - in the "x0, a" factor of the sweep to sweep 0.05 ms / div;
- ± 7% - in positions "x0, 1" and "x1" for the rest of the coefficients of the sweep;
Footnote. Working part scan is 80mm long section from the beginning, with the exception of the initial part of 70n;
Measurement error of the instrument oscilloscope S1-71 universal time intervals for a range of calibrated velocity scans from 10ns/del. to 100ms/del. when measured in the horizontal image size of 4 divisions and 10 divisions of the working section of the sweep - no more than:
- Main - ± 6%;
- In working conditions - ± 10%;
At the rate at which the measured amount of 5ns/del at the horizontal picture of 4 divisions and 10 divisions of the instrument error in measuring oscilloscope S1-71 universal time slots - no more than:
- Main - ± 10%;
- In working conditions - ± 12%;
Internal synchronization device scan oscilloscope C1-71 universal carried out:
- Sinusoidal signals in a frequency band of 3 ∙ 10 -6 MHz to 25 MHz at the minimum and maximum levels of 4.8 mm and 48 mm respectively;
- Sinusoidal signals unitoscilloscope S1-71 is universal in the frequency range from 25MHz to 100MHz with minimum and maximum levels, from 10mm to 48mm, respectively;
- Signal mains frequency 50Hz and 400Hz;
- Pulse signals of either polarity and 10 ns duration with a maximum repetition rate of not less 15MGts at the minimum and maximum levels, from 10mm to 48mm, respectively;
Instability start scanning device oscilloscope S1-71 universal - not more than 1 ns;
In the auto-synchronization signal is carried out with a minimum pulse repetition rate up to 100Hz;
External synchronization unit sweep oscilloscope S1-71 universal carried out:
- Sinusoidal signals in a frequency band of 3 ∙ 10 -6 MHz to 25 MHz at the minimum and maximum levels of the amplitude from 0.2 V to 5 V, respectively;
- Sinusoidal signals the device universal oscilloscope C1-71 in the frequency band from 25 MHz to 100 MHz at the minimum and maximum levels of the amplitude of 0.5 V to 5 V, respectively;
- Pulse signals of either polarity and 10 ns duration with a maximum repetition rate of not less 15MGts at the minimum and maximum levels of the amplitude of 0.5 V to 5 V, respectively;
Instability start scanning device oscilloscope S1-71 universal - not more than 1 ns;
In the auto-sync signals is carried out with a minimum pulse repetition rate up to 100Hz;
Parameters of the unit signals the oscilloscope S1-71 universal synchronization of external devices:
- On the nest «V» scan:
- The amplitude of the sawtooth voltage range from 5V to 10V at load 0.01 megohms in parallel with 50pF;
- On the nest "P" sweep:
- Stress amplitude in the range from 6V to 12V at load 0.01 megohms in parallel with 50pF;
When you press "SEARCH THE BEAM" instrument oscilloscope S1-71 universal image signal should appear in the operating side of the screen;
Adjusting the brightness of the image brightness must change from no to convenient for observation;
Adjusting the lighting of the instrument scale oscilloscope S1-71 universal coverage should change the scale of its complete absence to a comfortable lighting for reading on the scale;
The permissible level of voltage interference device oscilloscope C1-71 universal must be no more than:
- 80 dB - at frequencies from 0.15 MHz to 0.5 MHz;
- 74dB - at frequencies from 0.5 MHz to 2.5 MHz;
- 66dB - at frequencies from 2.5 MHz to 20 MHz;
The device may not cause acoustic noise over 60 dB at 1 meter from the unit;
Image signal delay deviceoscilloscope S1-71 universal in the path of the vertical deflection should provide views of the fronts of the signal at the operating frequency sweep;
The device is versatile oscilloscope C1-71 should retain its specifications within the standards established in the technical specifications after replacing it in the cathode-ray tube;
Podregulirovka permitted by existing bodies of adjustment provided a schematic diagram device and manual instrument oscilloscope S1-71 universal;
The amplitude of the input channel «Z», providing surveillance of brightness tags with a frequency of 20 MHz ∙ 10 -6 to 10 MHz:
- Minimum - no more than 2C;
- Maximum - at least 8B;
Isolation between the input power supply circuit network cable device oscilloscope S1-71 universal and the housing unit can withstand without breakdown AC voltage test:
- Under normal conditions - 1000V (rms);
- High humidity - 600V (rms);
The insulation resistance of this circuit device oscilloscope S1-71 universal relative to the body - not less than:
- Under normal conditions - 20 MW;
- Elevated temperature - 5 MW.
Time samoprogreva instrument oscilloscope S1-71 universal - no more than 15 minutes;
The device is powered from the mains voltage:
- 220 V ± 22 V with 50 Hz ± 0,5 Hz and harmonic content up to 5%;
- 115V ± 5,75 V or 220 V ± 11 V with a frequency of 400 Hz ± 12Gts and harmonic content up to 5%;
The power consumed by the device oscilloscope S1-71 universal mains at rated voltage - no more than 150V ∙ A;
The device is an oscilloscope C1-71 allows for universal continuous operation under the operating conditions for at least 8 hours;
Mean time between failures - at least 1,000 hours;
Overall dimensions oscilloscope S1-71 universal - no more 348H220H509mm;
Dimensions of laying the box - no more 524H301H628mm;
Dimensions of transport packages with laying box - no more 629X442X771mm;
Overall dimensions of shipping container unit oscilloscope S1-71 universal with a cardboard box - 494X415X838mm;
Weight of the device - no more than 19kg;
Weight of the device in the laying box - no more than 38kg;
Unit weight oscilloscope S1-71 Universal in a transport container - no more than 80kg;
Shelf-life instrument - at least 5 years;
The service life of the instrument oscilloscope S1-71 universal - at least 7 years;
Technical resource - at least 5,000 hours;
The emission unit oscilloscope S1-71 should be added the universal use of electrical circuits of principle;
Due to continuing work on improving the product, which increases reliability and improves the operating conditions, the design may be some minor changes;
The manufacturer guarantees the quality of the instrument oscilloscope S1-71 universal technical requirements specifications, subject to the consumer the terms and conditions of storage, transportation, installation, operation, established specifications and operational documents.

Photos: S1-71 (c1-71)

S1-71 (c1-71) oscilloscope image.
S1-71 (c1-71) oscilloscope image.
S1-71 (c1-71) front view.
S1-71 (c1-71) front view.
S1-71 (c1-71) rear view.
S1-71 (c1-71) rear view.


Яндекс цитирования