Radiometric devices >> oscilloscopes >> universal oscilloscope

S1-112A (c1-112a)

10 999 RUB
5 280 UAH
available:
6 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Oscilloscope, multimeter S1-112A (S1112A, S-1-112-A, S 1112 A, S1-112a, S-1112A, S 1112A, S1 112A, c1112a, c-1-112-a, c 1112 a , c-1112a, c 1112a, c1 112a)
 
Technical characteristics of the devices, multimeters oscilloscope S1-112A:
 
The line width of the beam - no more than 0.8 mm;
The main relative error of the coefficient of deviation device oscilloscope, multimeter S1-112A in the measurement of:
- 4, 6 divisions - no more than ± 4%;
- In two divisions - no more than ± 6%;
- With 1:10 divider when measured at 4, 6 divisions - no more than ± 6%;
- With 1:10 divider when measured in two divisions - no more than ± 8%;
Step response time (CT) - no more than 35ms, with 1:10 divider - not more than 70ms;
Release of HRP at the top of the instrument oscilloscope, multimeter S1-112A - no more than 10ms;
The time of establishment of HRP - no more than 120ms;
The uneven top of HRP - less than 3%;
The basic relative error of the instrument oscilloscope, multimeter S1-112A:
- To sweep mks/delenie-50ms/delenie 0.1 when measured at 6, 8, 10 divisions - no more than ± 4%;
- To sweep 0.05 ms / division and for the rest of the coefficients of the sweep when measured at four divisions - no more than ± 5%;
Measurement error of the DC voltage - ± (1 +0,1 U N / U x), where U n - the final value of the limit of measurement in; U x - measured quantity, V;
Accuracy of measurement device resistances oscilloscope Multimeter S1-112A - ± (2 +0,1 R H / R x), where R n - the final value of the limit of measurement, Ohm; R x - measured value, ohms;
The working part of the screen - 40h60mm;
Recession peaks of HRP on the duration of 4 ms - no more than 10%;
Input parameters values:
- Input resistance - 1 MW ± 0,02 MW;
- Input capacitance - 30pF ± 4pF;
Input parameters for the device work with 1:10 divider:
- Input resistance - 10M ± 0,5 MW;
- Input capacity - not bolee25pF;
Input parameters for the device work with a divider of 1:1:
- Input resistance - 1 MW ± 0,02 MW;
- Input capacity - up to 100 pF;
Permissible total value of permanent and temporary stresses on closed device input oscilloscope, multimeter S1-112A - no more than 250;
- When the variable component - no more than 30V;
Internal sync:
- Harmonic signal in the frequency range:
- When an image scale of 0,6-6,6 divisions - 100 Hz-2 ∙ 10 4 Hz;
- When an image scale of 1,5-6,6 divisions - 20Hz-10 ∙ 10 4 Hz;
- Pulse signals of either polarity with duration of 120ms or more in span of the image - 0,6-6,6 divisions;
- Personnel synchronous impulse television signal at scale of the image - 3-6,6 divisions;
The instability of the synchronization device oscilloscope, multimeter S1-112A does not exceed - 0.02 T-10ms, where T - the duration of the sweep, ms;
External synchronization is carried out:
- Harmonic signal amplitude from 0.5 V to 5 V in the frequency range 20 Hz-10 ∙ 10 4 Hz;
- Pulse signals of either polarity with duration of 120ms or more, the signal amplitude 0.5V-5V;
The range of the voltage measurement device oscilloscope, multimeter S1-112A DC either polarity - 0.001 V-1000 V;
Measuring range of active resistance - 0,001 ohms-2500 ohms;
Input impedance instrument oscilloscope Multimeter S1-112A in the measurement of DC voltage - 10 MW ± 0,5 MW;
Voltage AC power - 220V ± 22V;
The power consumed from the power supply - 24 V ∙ A;
Operation mode setup time oscilloscope Multimeter instrument S1-112A - 5 minutes;
Continuous operation time - 8:00;
Operating conditions:
- Ambient temperature - 10 º C to 35 º C;
- Relative humidity at 20 º C - up to 80%;
Limiting conditions of operation of the device oscilloscope, multimeter S1-112A:
- Ambient temperature - from -50 º C to +50 º C;
- Relative humidity at 20 º C - 95%;
Mean time between failures - at least 10,000 hours;
Average recovery time oscilloscope, multimeters devices S1-112A - 3 hours.